Search results for "General dentist"
showing 10 items of 3635 documents
Comparison of the shear bond strength of 3D printed temporary bridges materials, on different types of resin cements and surface treatment
2019
Background Thus, purpose of this study was to compare the shear bond strength of the resin cement and the resin modified glass ionomer cement on 3D printed temporary material for crowns and bridges in combination with different surface treatment modalities. Material and methods Test specimens VarseoSmile Temp material (Bego, Bremen, Germany) (n=64) in the form of rectangular blocks (n=32) and cylindrical test specimens (n=32) were printed using the Varseo S 3D printer (Bego, Bremen, Germany). The specimens were divided into 4 groups, with 8 specimens of each kind. Two groups (n=16 pairs) were blasted with Perlablast® Micro [PM] 50µm (Bego, Bremen, Germany) and two groups (n=16 pairs) were b…
Posttraumatic carotid-cavernous fistula: Pathogenetic mechanisms, diagnostic management and proper treatment. A case report.
2016
Journal Article; UNLABELLED Carotid-cavernous fistulas are an uncommon diseases characterized by abnormal communications between arteries and veins located in the cavernous sinus. According with Barrow´s classification they could be divided in two groups: direct and indirect. The typical symptoms showed by theses pathologies are: pulsating exophthalmos and orbital blow. The present study describes a case of direct posttraumatic carotid-cavernous fistula in a 26 years old man. Furthermore, we present the images that we used to make the diagnosis. In this light, we decided to treat this case with endovascular approach after considering several therapeutic options. The aim of the present repor…
Microbiological characterization and effect of resin composites in cervical lesions
2017
Background Non carious cervical lesions associated to muscle hyperfunctions are increasing. Microhybrid resin composites are used to restore cervical abfractions. The purpose of this study was to investigate if resin composites modify tooth plaque, inducing an increment of cariogenic microflora and evaluate their effect, in vivo and in vitro, against S. mutans. Material and Methods Eight abfractions were restored with two microhybrid resin composites (Venus, Heraeus-Kulzer® and Esthet-X, Dentsply®), after gnatological therapy, in three patients with muscle hyperfunctions. For each abfraction three samples of plaque were taken from the cervical perimeter: before the restoration, one week and…
Analysis of the morphology and composition of tooth apices apicectomized using three different ablation techniques.
2011
Objectives: To investigate apicectomies performed using burs, a CO2 laser or an Er:YAG laser and to evaluate the following aspects: morphology of apicectomized surfaces, presence of failures at the dentin/obturation material interface (marginal fit) of the apical portions of the root canals, and the proportions of chemical elements in the apicectomized surfaces. Study design: Twenty-four teeth were divided into three groups of eight and each group underwent apicectomy by one of three different ablation techniques: bur, CO2 laser or Er:YAG laser. The morphology of the apicectomized surfaces was then analyzed using scanning electron microscopy and their chemical composition was analyzed by en…
Clinical measurement of tooth wear: Tooth Wear Indices
2012
Attrition, erosion, and abrasion result in alterations to the tooth and manifest as tooth wear. Each classification corresponds to a different process with specific clinical features. Classifications made so far have no accurate prevalence data because the indexes do not necessarily measure a specific etiology, or because the study populations can be diverse in age and characteristics. Tooth wears (attrition, erosion and abrasion) is perceived internationally as a growing problem. However, the interpretation and comparison of clinical and epidemiological studies, it is increasingly difficult because of differences in terminology and the large number of indicators/indices that have been deve…
Investigation of water sorption and aluminum releases from high viscosity and resin modified glass ionomer.
2019
Background High viscosity glass ionomer cement (HVGIC) and resin-modified glass ionomer cement (RMGIC) have recently been clinically preferred thanks to their numerous advantages. However, initial moisture contamination has a negative effect on the mechanical and physical properties of these cements. The aim of this study was in vitro of HVGICs and RMGICs, with and without surface protection, on water sorption, solubility and release of aluminum. Material and Methods In this study, as HVGICs; Equia Forte, IonoStar Plus, Riva Self Cure; as RMCIS, Ionolux and Riva Light Cure; and as control, Z250 universal composite was used. Equia coat, Voco varnish and Riva coat were chosen as surface prote…
Hybrid layers of etch-and-rinse versus self-etching adhesive systems.
2010
Objective: To evaluate the effectiveness in the formation of resin tags, adhesive lateral branches and hybrid layers of five adhesive systems, when bonding to dentine. Material and Methods: Flat dentin surfaces from 25 molars were bonded with several adhesive systems according to the manufacturers? instructions. Composite build-ups were constructed incrementally with Tetric Ceram. The Specimens were sectioned parallel to the long axis. One section was treated with phosphoric acid and sodium hypochlorite in order to reveal the hybrid layer formation. The other section was stored in 30% hydrochloric acid to detect resin tags and adhesive lateral branch formation. Results: The two etch-and-rin…
Accuracy combining different brands of implants and abutments
2013
Objective: To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination. Study design: Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S.A. (Barcelona, Spain), 3i Biomet (Palm Beach, U.S.A.), BTI (Alava, Spain) and Nobel Biocare (Göteborg, Sweden), with standard 4.1 mm heads and external hexagons, and their respective machined prosthetic abutments. The implant-to- abutment fit/misfit was evaluated at four points (vestibular, lingual/palatine, mesial and distal) between implants and abutments of the same brand and different brands,…
A controlled clinical study of periodontal health in anticoagulated patients : assessment of bleeding on probing
2017
Background According to the Spanish Society of Cardiology, 700,000 patients receive oral anticoagulants, and in these cases bleeding on probing (BOP) could be altered. However, no studies have analyzed the periodontal status of these patients and the effects anticoagulants may have upon BOP. A study was made of the possible relationship between plaque index, probing depth, INR (International Normalized Ratio) and acenocoumarol dose versus the clinical signs of BOP in a sample of anticoagulated patients. Likewise, an analysis was made of oral hygiene habits and attitude towards bleeding in these patients. Material and Methods A controlled observational clinical study was made in La Ribera Ho…
Dental management of patients receiving anticoagulant and/or antiplatelet treatment
2013
Introduction: Adequate hemostasis is crucial for the success of invasive dental treatment, since bleeding problems can give rise to complications associated with important morbidity-mortality. The dental treatment of patients who tend to an increased risk of bleeding due to the use of anticoagulant and/or antiplatelet drugs raises a challenge in the daily practice of dental professionals. Adequate knowledge of the mechanisms underlying hemostasis, and the optimized management of such patients, are therefore very important issues. Objectives: A study is made of the anticoagulant / antiplatelet drugs currently available on the market, with evaluation of the risks and benefits of suspending su…