Search results for "Genetic Structures"
showing 10 items of 2107 documents
Primary motor area contribution to attentional reorienting after distraction
2008
The anatomical structures involved in distraction-related processing in the auditory domain were investigated using magnetoencephalography. Participants performed a duration-discrimination task on a sequence of 200 and 400 ms long tones. Infrequent (12%) task-irrelevant pitch changes resulted in slower discriminative responses and more errors. Event-related potentials to these changes show an increased N1, a mismatch negativity, a P3a, and a reorienting negativity. The event-related magnetic fields revealed focal activities in superior and medial temporal areas in the N1/mismatch negativity time range. No significant activity was found in the P3a interval. In the reorienting negativity inte…
Parafoveal versus foveal N400s dissociate spreading activation from contextual fit.
2009
Using concurrent electroencephalogram and eye movement measures to track natural reading, this study shows that N400 effects reflecting predictability are dissociable from those owing to spreading activation. In comparing predicted sentence endings with related and unrelated unpredicted endings in antonym constructions ('the opposite of black is white/yellow/nice'), fixation-related potentials at the critical word revealed a predictability-based N400 effect (unpredicted vs. predicted words). By contrast, event-related potentials time locked to the last fixation before the critical word showed an N400 only for the nonrelated unpredicted condition (nice). This effect is attributed to a parafo…
Impairments in top down attentional processes in right parietal patients: Paradoxical functional facilitation in visual search
2014
AbstractIt is well known that the right posterior parietal cortex (PPC) is involved in attentional processes, including binding features. It remains unclear whether PPC is implicated in top-down and/or bottom-up components of attention. We aim to clarify this by comparing performance of seven PPC patients and healthy controls (HC) in a visual search task involving a conflict between top-down and bottom-up processes. This task requires essentially a bottom-up feature search. However, top-down attention triggers feature binding for object recognition, designed to be irrelevant but interfering to the task. This results in top-down interference, prolonging the search reaction time. This interfe…
Ranibizumab for Branch Retinal Vein Occlusion Associated Macular Edema Study (RABAMES): six-month results of a prospective randomized clinical trial
2014
Purpose To compare standard-of-care grid laser photocoagulation versus intravitreal ranibizumab (IVR) versus a combination of both in the treatment of chronic (>3 months) macular oedema secondary to branch retinal vein occlusion. Methods Prospective, randomized, multicentre clinical trial. Thirty patients with a best-corrected visual acuity (BCVA) between 20/320 and 20/40 were randomized 1:1:1 to receive grid laser or three monthly injections of 0.5 mg IVR or both followed by 3 months of observation. Results Mean change from baseline BCVA at month 6 was +2 letters [laser; 0.04 logMAR, 95% confidence interval (−0.17; 0.25)], +17 letters [IVR; 0.34 (0.19; 0.5)] and +6 letters [combination; 0.…
Aqueous Humor Levels of Vascular Endothelial Growth Factor in Retinitis Pigmentosa
2008
PURPOSE To determine the level of vascular endothelial growth factor A (VEGF-A) in aqueous humors of patients with retinitis pigmentosa (RP). METHODS A prospective, comparative control study. Aqueous humor was collected from 16 eyes of 16 patients with RP. The level of VEGF-A was determined with a commercially available enzyme-linked immunosorbent assay kit. The control group comprised 16 aqueous samples from 16 patients about to undergo cataract surgery and without any other ocular or systemic diseases. RESULTS The concentration of VEGF-A in aqueous humor was markedly lower in patients with RP than in control subjects (Mann-Whitney U test, P < 0.001). The level of VEGF-A was 94.9 +/- 99.8 …
Elevated protein carbonyl and HIF-1α levels in eyes with proliferative diabetic retinopathy.
2013
Purpose: To evaluate the role of protein carbonyls and hypoxia inducible factor-1a (HIF-1a) in diabetic eyes with proliferative diabetic retinopathy (PDR). Methods: Prospective consecutive controlled observational study was performed. Vitreous samples were collected at the start of the 3-ppp vitrectomy. Protein carbonylation analysis was performed by Western blotting with antibody against 2,4-Dinitrophenol (anti-DNP), following derivatization of protein carbonyls with 2,4 Dinitrophenylhydrazine (DNHP). Protein carbonylation was quantified by scanning densitometry analysis and relativized to the total amount of protein into the ponceau staining of membranes. Vitreous HIF-1 a was determined w…
Monocular Versus Binocular Calibrations in Evaluating Fixation Disparity With a Video-Based Eye-Tracker
2015
When measuring fixation disparity (an oculomotor vergence error), the question arises as to whether a monocular or binocular calibration is more precise and physiologically more appropriate. In monocular calibrations, a single eye fixates on a calibration target that is taken as having been projected onto the center of the fovea; the corresponding vergence state represents the heterophoria (the resting vergence position), which has no effect on the calibration procedure. In binocular calibrations, a vergence error may be present and may affect the subsequent measurement of the fixation disparity during binocular recordings. This study includes a test of the precision of both monocular and …
Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creatio…
2010
Purpose To compute and compare visual acuity, refractive outcomes, and anterior corneal aberration changes after myopic laser in situ keratomileusis (LASIK) with flap creation by a mechanical microkeratome and by a femtosecond laser. Setting Private practice refractive surgery center, Valencia, Spain. Design Comparative case series. Methods Patients were assigned to have LASIK flap creation with a mechanical microkeratome (Carriazo-Barraquer) or a femtosecond laser (IntraLase). The Visx S2 excimer laser was used for myopic ablation in all cases. Main outcome measures included uncorrected and corrected distance visual acuities and the defocus equivalent. Higher-order aberrations (HOAs) were …
Visual performance of two simultaneous vision multifocal contact lenses
2012
Purpose To evaluate and compare the visual performance of two simultaneous vision multifocal contact lenses (CLs). Methods In this cross-over study design 20 presbyopic subjects were fitted with two different simultaneous vision multifocal CLs (the PureVision Multifocal Low Add and Acuvue Oasys for Presbyopia) in random order. After 1 month, binocular distance visual acuity (BDVA) under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions, binocular near visual acuity (BNVA), binocular distance contrast sensitivity function (CSF) under photopic and mesopic conditions, binocular near CSF and defocus curve were measured. Subjects were then refitted with the alternative correction and the proc…
Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system.
2007
To assess the quality of vision in patients who had implantation of asymmetric Acri. Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The study comprised 343 consecutive patients who had bilateral implantation of the Acri. Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were…