Search results for "Genetic Structures"
showing 10 items of 2107 documents
Visual and optical performance with the ReZoom multifocal intraocular lens
2011
Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…
Optical quality after instillation of eyedrops in dry-eye syndrome
2010
Purpose To study the effect of eyedrop instillation on the optical quality of the air–tear film interface at the anterior cornea in cases of dry eye. Setting University of Valencia, Valencia, Spain. Methods Corneal aberrations (total, spherical-like, and coma-like) were determined from corneal elevation maps and purpose-designed software in cases of dry eye before, immediately after, and 10 minutes after lubricating eyedrop instillation (Blink Intensive Tears). All data were decomposed using Zernike polynomials to yield the root-mean-square wavefront deviations for pupil diameters of 3.0 mm and 5.5 mm. Outcome measures included comparison with clinical tear breakup time (TBUT). Results Wave…
PE-11, a peptide derived from chromogranin B, in the rat eye.
2010
The aim of the study was to investigate the presence and distribution of PE-11, a peptide derived from chromogranin B, in the rat eye. For this purpose, newborn rats were injected with a single dosage of 50mg/kg capsaicin subcutaneously under the neck fold and after three months, particular eye tissues were dissected and the concentration of PE-11-like immunoreactivity was determined by radioimmunoassay. Furthermore, PE-11-like immunoreactivities were characterized in an extract of the rat eye by reversed phase HPLC. Then, the distribution pattern of PE-11 was investigated in the rat eye and rat trigeminal ganglion by immunofluorescence. As a result, PE-11 was present in each tissue of the …
Prospective visual evaluation of apodized diffractive intraocular lenses
2006
To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…
Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.
2011
PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…
Prospective study of the Acri.LISA bifocal intraocular lens
2007
To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…
Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation
2007
Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…
Intraocular pressure in samples of elderly Finnish and Swedish men and women.
1994
Abstract Intraocular pressure was measured in 231 systematically sampled 75-year-old men and women in Goteborg, Sweden and in 284 75-year-old and 201 80-year-old residents in Jyvaskyla, Finland as part of a comparative study on functional capacity and health, NORA 75 (Nordic Research on Ageing). After excluding the cases reporting glaucoma in their medical history or using drugs for glaucoma treatment there were no significant differences in the distributions of intraocular pressure between the men (mean intraocular pressure in the right eye 15.1 mmHg, left eye 15.0 mmHg) and women (mean intraocular pressure in the right eye 15.5 mmHg, left eye 15.8 mmHg) in Goteborg. In Jyvaskyla the 75-ye…
Retinal light sensitivity of the central visual field among 70- to 81-year-old men and women.
2009
Retinal light sensitivity of the central visual field (0-30 degrees), visual acuity, intraocular pressure and pupillary size were screened in 42 men and 42 women aged 70 to 81 years. The subjects were randomly selected from the population register. After excluding the diagnosed glaucoma cases, the men had better visual field light sensitivity values than the women. They also had lower intraocular pressure and a wider pupillary diameter than the women, whereas there were no differences in visual acuity between the sexes. When the effect of pupillary size was controlled the differences in visual field light sensitivity values between men and women became non-significant. Among these elderly p…
Sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsular rupture in cataract surgery.
2012
Purpose. To evaluate the safety of a foldable acrylic single-piece intraocular lens (IOL) in cases of complicated cataract surgery and sulcus implantation. The setting was University and private anterior segment surgery practices. Methods. In this observational case series study, 13 eyes of 13 patients were included after complicated phacoemulsification with extensive posterior capsule rupture with or without vitreous loss. A foldable acrylic single-piece IOL (Rayner Superflex 620H; Rayner Intraocular Lenses Limited, Hove, East Sussex, UK) was implanted in the ciliary sulcus in each eye. Postoperative follow-up included best-corrected visual acuity, anterior segment biomicroscopy, IOL centr…