Search results for "Germanium"
showing 10 items of 249 documents
Implantation-decay station for low-energy proton measurements
2013
Abstract We have built an implantation-decay station for β - delayed proton and α decay studies at the focal plane of the Momentum Achromat Recoil Spectrometer (MARS) at the Cyclotron Institute of Texas A&M University. Energetic secondary beams with a small momentum spread are stopped in a controlled manner into a very thin silicon strip detector. In addition, high-purity germanium detectors are installed for γ ray detection. Here we give a description of the setup and the observed performance down to E p ≈ 200 keV using implanted 23 Al and 31 Cl sources.
Resolution, efficiency and stability of HPGe detector operating in a magnetic field at various gamma-ray energies
2008
Abstract The use of High Purity Germanium detectors (HPGe) has been planned in some future experiments of hadronic physics. The crystals will be located close to large spectrometers where the magnetic fringing field will not be negligible and their performances might change. Moreover high precision is required in these experiments. The contribution of magnetic field presence and long term measurements is unique. In this paper the results of systematic measurements of the resolution, stability and efficiency of a crystal operating inside a magnetic field of 0.8 T, using radioactive sources in the energy range from 0.08 to 1.33 MeV, are reported. The measurements have been repeated during sev…
Probing structural changes in the very neutron-deficient Os isotopes with recoil-decay tagging
2005
In recent years, the exploitation of the iecoil-decay tagging (RDT) technique with,large arrays of germanium detectors has revealed much information about the structure of heavy nuclei approaching the proton drip line. The yrast bands of the N <= 93 osmium isotopes have been identified in a campaign of tagging experiments using various spectrometer arrays coupled to the RITU gas-filled separator based at the University of Jyvaskyla. Trends in the yrast state excitation energies have indicated a transition from gamma-soft triaxial to near-spherical shapes with decreasing neutron number. Recent experimental results for Os-162 obtained with the JUROGAM and GREAT spectrometers also indicate the…
Imaging test setup for the coded-mask /spl gamma/-ray spectrometer SPI
2001
The European Space Agency's International Gamma-Ray Astrophysics Laboratory (INTEGRAL) will be launched in 2002. One of its two main instruments is the spectrometer SPI. It uses 19 HPGe detectors to observe the sky in the energy range of 20 keV to 8 MeV with a resolution of /spl Delta/E/E/spl ap/0.2%. Directional information is obtained using a coded mask. The expected angular resolution is about 20, The SPI imaging test setup (SPITS) was built at the Max-Planck-Institut fur Extraterrestische Physik, Germany, to allow experimental verification of the imaging properties of SPI. SPITS consists of a coded hexagonal uniformly redundant array (HURA) mask and two germanium detectors. The mask is …
Study of background characteristics of a low-level HPGe spectrometer with passive shielding in various configurations
1997
Abstract A low-background germanium spectrometer has been investigated with different combinations of shielding materials in two locations at ground level. In particular, seven shielding configurations have been tested in a room with thick walls and ceiling. The background components, peaks and continuum in the 50–2600 keV energy region, obtained in the several experimental conditions are reported and discussed.
Laboratory astrophysics and microanalysis with NTD-germanium-based X-ray microcalorimeters
2000
With the ability to create cosmic plasma conditions in the laboratory it is possible to investigate the dependencies of key diagnostic X-ray lines on density, temperature, and excitation conditions that exist in astrophysical sources with X-ray optics and a high-resolution X-ray microcalorimeter. The same instrumentation can be coupled to scanning electron microscopes or X-ray fluorescence probes to analyze the elemental and chemical composition of electronic, biological, geological and particulate materials. We describe how our microcalorimeter and X-ray optics provide significantly improved capabilities for laboratory astrophysics and microanalysis.
Spectroscopy of Transfermium Nuclei
2006
The advent of efficient recoil separator devices coupled to large arrays of germanium detectors and versatile focal plane detection systems has in recent years allowed a wealth of spectroscopic information to be obtained for transfermium nuclei. At the Department of Physics at the University of Jyvaskyla, the RITU gas‐filled separator is employed in conjunction with the GREAT focal plane spectrometer and the JUROGAM array of germanium detectors. Whilst initial studies using these devices concentrated on even‐even nuclei, more recent experiments have attempted to study single‐particle properties by examining the structure of odd‐mass nuclei and multi‐quasiparticle states. An overview of the …
Nuclear Structure Properties of Neutron Rich Ge-Br Isotopes in the Astrophysical r-Process
2006
The astrophysical r-process is responsible for synthesis of roughly half of the elements heavier than iron. In spite of this significance, there are many uncertainties regarding the site of the r-process and the neutron-rich nuclei involved. Studying these nuclei presents a challenge, as they lie far from the valley of stability. Nuclear properties such as β decay half-lives and βdelayed neutron emission probabilities are critical inputs for r-process models. The neutron rich Ge-Br isotopes are in the region just after the N=50 bottle neck in the “classical” r-process, or may serve as seed material for the high entropy neutrino-wind r-process. Neutron rich nuclei play an important role in b…
Massive neutrinos and right-handed weak currents in double beta decay.
1993
The contributions of right-handed weak currents in neutrinoless double beta decay are studied taking explicitly into account the mass corrections to the intermediate neutrino propagator. Due to these corrections the right-handed currents become effective even if all neutrinos are light ([ital m][sub [nu]][gt]10 MeV). Explicit expressions for the neutrino-momentum integrals and the decay half-life are derived. As an example two neutrino-mass scenarios containing the hypothetical 17-keV neutrino are discussed. The experimental half-life of the [sup 76]Ge[r arrow][sup 76]Se decay is used to obtain an upper limit for a new kind of effective right-handed coupling within the two scenarios.
Penning-trap-assisted study of 115Ru beta decay
2011
The beta decay of 115Ru has been studied by means of Penning-trap-assisted beta and gamma spectroscopy at the IGISOL facility. The level scheme of 115Rh has been substantially extended and compared with the level systematics of lighter rhodium isotopes. Tentative candidates for three states of the deformed K = 1/2 band have been suggested. The beta-strength distribution of the beta decay of 115Ru differs from the beta decays of 111, 113, 113mRu isotopes due to non-observation of the 3-quasiparticle states in 115Rh. The decay properties of 115Ru indicate a spin-parity of (3/2+ for its beta-decaying ground state. In addition, possible Nilsson states as well as the shape and spin transitions i…