Search results for "Goldm"

showing 7 items of 17 documents

Quantitative corneal anatomy: evaluation of the effect of diabetes duration on the endothelial cell density and corneal thickness.

2014

Purpose To evaluate the differences in endothelial cell density (ECD) and central corneal thickness (CCT) between type II diabetic patients and age-matched healthy controls, and determine the impact of time from diagnosis. Methods This is a comparative study of 77 eyes of type II diabetic patients (33 males, 44 females) and 80 eyes of healthy subjects (42 males, and 38 females) whose ages ranged from 38 to 56 years. CCT, ECD, HbA1c levels, and Goldmann tonometry were measured. Results The CCT was significantly higher and the ECD significantly lower in long-term diabetic patients (10 years + since diagnosis) when compared with short-term diabetic patients (<1 year since diagnosis) and contro…

Diabetes durationAdultMalemedicine.medical_specialtyTime Factorsgenetic structuresCorneal PachymetryCell CountType ii diabetesCorneaHba1c levelOphthalmologyInternal medicineMedicineHumansRetrospective StudiesGlycated Hemoglobinbusiness.industryEndothelium CornealHealthy subjectsMiddle AgedCorneal structureeye diseasesSensory SystemsEndothelial cell densityGoldmann tonometryOphthalmologyEndocrinologyDiabetes Mellitus Type 2Disease ProgressionFemalesense organsAnalysis of variancebusinessOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry.

2016

AIMS The tonographic effect is a phenomenon of intraocular pressure (IOP) reduction following repeated tonometry. This study examines whether the tonographic effect occurs following IOP measurement performed with Ocular Response Analyzer (ORA). METHODS Both eyes of 31 glaucoma patients and 35 healthy controls underwent nine IOP-measurements performed with GAT and ORA. The number of GAT and ORA measurements performed on each eye differed depending on the randomly allocated investigation scheme. Central corneal thickness (CCT), anterior chamber volume (ACV) and anterior chamber depth (ACD) were assessed with Pentacam before and after the repeated GAT/ORA measurements. RESULTS There was no sta…

Intraocular pressuregenetic structuresEye DiseasesPhysiologyGlaucomalcsh:MedicineWalkingGoldmann applanation tonometryCornea0302 clinical medicineMedicine and Health SciencesMedicineBiomechanicslcsh:ScienceMultidisciplinaryOphthalmic ProceduresDrugsMiddle AgedFemaleAnatomyResearch ArticleAdultmedicine.medical_specialtyOcular AnatomySurgical and Invasive Medical ProceduresCorneal hysteresis03 medical and health sciencesTonometry OcularOcular SystemOphthalmologyHumansPain ManagementIn patientIntraocular PressureAgedAnestheticsPharmacologybusiness.industryBiological Locomotionlcsh:RBiology and Life SciencesGlaucomamedicine.diseaseeye diseasesOphthalmologyCase-Control Studies030221 ophthalmology & optometryEyeslcsh:Qsense organsbusinessHead030217 neurology & neurosurgeryPloS one
researchProduct

Safety and performance of a suprachoroidal sensor for telemetric measurement of intraocular pressure in the EYEMATE-SC trial

2023

AimTo investigate the safety and performance of a telemetric suprachoroidal intraocular pressure (IOP) sensor (EYEMATE-SC) and the accuracy of its IOP measurements in open angle glaucoma (OAG) patients undergoing simultaneous non-penetrating glaucoma surgery (NPGS).MethodsProspective, multicentre, open-label, single-arm, interventional clinical trial. Twenty-four eyes of 24 patients with OAG regularly scheduled for NPGS (canaloplasty or deep sclerectomy) were simultaneously implanted with an EYEMATE-SC sensor. Six-month follow-up on the sensor’s safety and performance as well as on the level of agreement between the EYEMATE-SC measurements and IOP measurements with Goldmann applanation tono…

Intraocular pressuremedicine.medical_specialtyOpen angle glaucomaDRAINAGEmedicine.medical_treatmentGlaucomaCANALOPLASTYGOLDMANN APPLANATION TONOMETRYTERMGoldmann applanation tonometrytreatment surgeryCellular and Molecular NeuroscienceDYNAMIC CONTOUR TONOMETRYOphthalmologyMaximum differenceGlaucoma surgerymedicineDevice migrationTrial registrationHEALTHYbusiness.industrymedicine.diseaseSensory SystemsOphthalmologyglaucomaIMPLANTATIONbusinessintraocular pressureBritish Journal of Ophthalmology
researchProduct

Conoscenza e percezione: epistemologie cognitiviste e naturalizzazione del relativismo

2010

Percezione Cognizione Relativismo Kuhn Fodor Goldman
researchProduct

Uso del tonometro e rischio infettivo ; valutazione dell'efficacia di differenziali tipi di disinfettanti.

2006

Obiettivo: valutare e confrontare l’efficacia dei più comuni tipi di disinfettanti per la disinfezione dei coni tonometrici e trarre alcune indicazioni sulla applicabilità alla realtà clinico-diagnostica in campo oftalmologico. Materiali e metodi: coni tonometrici monouso sterili, previamente contaminati con ceppi standard di Staphylococcus aureus, Bacillus subtilis, Pseudomonas aeruginosa e Candida albicans sono stati testati, dopo semplice detersione o disinfezione con acqua ossigenata al 3%, benzalconio cloruro allo 0.5%, Minuten wipes (Alpro® ), Pantasept® allo 0.5% secondo le linee guida del CDC di Atlanta. Risultati: la semplice detersione è stata inefficace contro tutte le specie tes…

Settore MED/30 - Malattie Apparato VisivoCono tonometrico tonometro di Goldmann Staphylococcus aureus Bacillus subtilis Pseudomonas aeruginosa Candida albicans acqua ossigenata Pantasept® Benzalconio cloruro
researchProduct

Latvijas ģimenes paaudzēs, 2018

2019

Pētījums aptver visas vecuma grupas: gan jaunus cilvēkus patstāvīgās dzīves sākumā (no 18 gadu vecuma), gan pieredzes bagātus &mdash; citās vecuma grupās (līdz 79 gadu vecumam), sniedzot precīzu informāciju par cilvēka dzīves galvenajiem demogrāfiskajiem notikumiem un cikliem vairāku paaudžu dzīvē, sākot jau no 1950. gadu vidus. Aptaujā tiek iegūta informācija par &scaron;ādām tēmām: pāreja uz pieaugu&scaron;o dzīvi (mācības un darbs, vecāku mājas atstā&scaron;ana, pirmās partnerattiecības, jaunas ģimenes veido&scaron;ana, labklājība un trūkums; kopdzīve un ģimenes stabilitāte (daudzveidīgās ģimenes formas, balanss starp darbu un ģimeni, pienākumu sadale starp vīrie&scaron;iem un sievietēm,…

demographyģimene - paaudzeslongitudinal researchdzīves gājumsfamily planningMaris Goldmanis:SOCIAL SCIENCES::Social sciences::Social work::Family research [Research Subject Categories]Latvijasubjektīvā labklājībademogrāfijaģimeneIlze Koroleva:SOCIAL SCIENCES::Social sciences::Demography [Research Subject Categories]veselībalife satisfactionIja TrapeznikovapaaudzesGeneration and Gender ProgrammehealthLatviaAleksandrs Aleksandrovsģimene - labklājībasubjective well-beingsocioloģijalife course analysis
researchProduct

Dating of Archaeological Gold by Means of Solid State Electrochemistry

2018

[EN] In archaeology and history of art, age determination is a fundamental analytical problem. While several techniques for age determination of various materials, like radiocarbon dating, are established, these methods cannot be applied for metals, for which new techniques have to be developed. For the first time a dating method for archaeological gold objects is described which is based on a corrosion clock and electrochemical measurements, using the voltammetry of immobilized particles. Samples are prepared by one touch' with a graphite pencil, only transferring a few nanograms of the archaeological gold. The method has been calibrated with the help of a series of well-documented gold sp…

media_common.quotation_subjectSolid-state02 engineering and technologyArt010402 general chemistry021001 nanoscience & nanotechnology01 natural sciencesArchaeologyGoldmCatalysis0104 chemical sciencesArchaeologyPINTURAElectrochemistryCorrosion clockDating0210 nano-technologymedia_commonChemElectroChem
researchProduct