Survey on power increase of power by employment of PV reconfigurator
2015
This paper shows the performance of a PV system under shadow projection on PV panels. The reconfiguration techniques, employing a microprocessor-based system, modifies the layout of the PV plant by physically changing the connections among modules, in order to recover the loss of power due to the shadows. Different cases have been considered to evaluate the increase of power.
Uprating an Overhead Line. Italian TSO Applications for Integration of RES
2013
The increase of Renewable Energy Sources (RES) production units has caused significant changes in the electrical system configuration. The existing structural asset isn't adequate to dispatch these new power flows that, at same time, should be favorite by various TSOs in order to obtain incentives. The outage of primary substations on the grid and the increase of consumptions have caused growing load currents on existing overhead line. This paper, after introducing thermal resistant conductors and Dynamic Rating (DR) solutions, reports an applications used by TERNA Group S.p.A. (Italian TSO). These systems are already installed on lines and they are contributing to increase power flows than…
Distribution grid analysys through PSAT open source tools
2015
In this paper a study of an electrical distribution grid with presence of renewable energy sources performed using the Power System Analysis Tool is presented. The paper describes the load flow analysis of a real existing grid owned by the Italian DSO “ENEL Distribuzione SpA” and located in an urban area.
Green Data Centres providing ancillary services to power grid
2015
This work investigates the possibility for a Data Centre to provide services to the Grid. In particular, the paper simulates a sudden shift of frequency because of a power decrease and estimates how a real-life Data Centre can contribute the secondary frequency regulation.
A New Device for the Control and the Connection to the Grid of Combined RES-based Generators and Electric Storage Systems
2013
In this paper a new device for the control and the connection to the supply utility grid of combined RES-based generators and electric storage systems is presented. The device is a bidirectional converter that can be controlled so as to facilitate the interface between the low voltage grid and photovoltaic or wind generators combined with batteries, contemporary addressing the requirements of the reference technical standards for users connection and providing different ancillary services. In the paper the functioning of the device and its circuit diagram are described, the single parts are shown and the potentiality of its control system are commented. © 2013 IEEE.
Narrowband power line communications for medium voltage smart grids
2014
The aim of the paper is to show how narrowband power line communications (NB-PLCs) can be a valid solution for medium voltage grids. Advantages and drawbacks of this solution are analyzed, starting from some experimental communication results, which were carried out on the medium power system networks of the islands of Ustica and Favignana, in the presence of the net voltage. Furthermore, some communication architectures and hardware prototypes based on NB-PLCs are proposed for different smart grids applications.
New solutions for prefabricated secondary substations in the view of sustainability
2016
The secondary substations will assume an important role as “smart nodes” of the smart grid. So in few years there will be a widespread dissemination on the territory of this apparatus. Consequently, great care have to be taken not only on safety issues, but also on the constructive methodology, in order to determine low environmental impact and decommissioning cost. This paper focuses on innovative solutions for the realization of prefabricated secondary substations, in the direction of sustainability. Innovative layout and enclosure topologies have been here taken into account. In particular, by considering that the substation concrete box is, at the same time, uneconomical and with strong…
Electrochemical energy storage mitigating impact of electric vehicle on the electric grid: Two Italian case studies
2017
In the framework of the Italian R&D project i-Next two pilots plants were realized aiming at demonstrate benefits coming from the adoption of electrochemical energy storages (Lithium ion batteries and hydrogen) integrated with renewable energy sources. In the present study the preliminary results coming from the demo sites operations are reported paying attention to the impacts to the grid.
An optimization location scheme for electric charging stations
2013
International audience; Due to environmental issues, electric mobility is one of the mobility alternatives that are receiving a huge attention nowadays. In fact, in the last few years electric vehicles have entered the world's car market. This revolutionary technology requires a fast deployment of electric charging stations since the key issue in this system is recharging the batteries. In this work, we propose an optimized algorithm to locate electric-vehicles charging stations. Different factors and limitations are considered and a real case study is given as an application. We first determine the appropriate strict constraints and cost of charging stations' location; and then we propose …
Impedance estimation of FEA's grid in fiji islands by V-I measurement by using the synchronous reference frame-PLL
2017
In recent years there has been a significant increase in distributed renewable energy generation feeding into the grid, with resulting detriment of the stability of the network, since present networks have not been designed for this purpose. To feed-in these renewable energy sources with minimum impact, it is essential to know a few grid parameters (voltage, current, grid impedance) at the point in which power supply is convenient. For this purpose in this paper an algorithm is proposed to obtain the estimated network impedance. This algorithm operates in time domain by a synchronous reference coordinate transformation, it requires only the measurement of the phase voltage with no-load and …