On the Interconnections of HV–MV Stations to Global Grounding Systems
2019
The interconnection of grounding systems of HV-MV stations via the armors of medium voltage cables, is herein analyzed to verify the effects on touch voltages in ground-fault conditions. The major contributions of this paper are two: the analysis of the impact of an HV ground-fault on a global grounding system (GGS), and the analysis of the parameters that may affect safety due to the interconnection between HV-MV stations and the GGS. The authors have analyzed cases when the connection of an HV-MV station to a GGS improves safety, and then may introduce hazards under ground-fault conditions. Two main issues are herein discussed: 1) the transfer of dangerous voltages to substations, due to …
Grounding ontologies in the external world
2017
The paper discusses a case study of grounding an ontology in the external world by a cognitive architecture for robot vision developed at the RoboticsLab of the University of Palermo. The architecture aims at representing symbolic knowledge extracted from visual data related to static and dynamic scenarios. The central assumption is the principled integration of a robot vision system with a symbolic system underlying the knowledge representation of the scene. Such an integration is based on a conceptual level of representation intermediate between the sub-symbolic processing of visual data and the declarative style employed in the ontological representation.
A parametric analysis of the transient behavior of lightning protection systems
2005
The paper have the purpose of investigate the influence of different parameters to enable better understanding of the transient performance of complex lightning protection systems (LPS). Lightning discharges constitute the major source of atmospheric or natural noise that can interfere with electric and electronic installations. The electromagnetic characterisation of the LPS environment plays a fundamental role in order to prevent unwanted coupling phenomena that may generate abnormal signals, electric stresses dangerous for the insulation of electric components, disruptive discharges and danger to persons. The model, developed by the authors, is based on a field-approach: the numerical so…
Communicating with home, coping without home – Trusting to the mediating capacity of blogging
2021
Abstract In the early 21st century, blogs exploded onto the digital media scene and soon became a popular means of travel writing. However, rather than considering blogs as a straightforward tool to simply share stories and experiences, in this article, we set out to explore the role of blogs as a mediating technology (Verbeek, 2005a), especially during difficult times abroad. By analysing the blogs of expatriate Australians who were volunteers in Bangladesh in 2014/2015 as well as interviews with the bloggers, we are able to show how the blogs' affordances inform the coping process, highlighted, in particular, in an active and highly reflective engagement with the blog's unique situatednes…
Towards Dialogic Teaching in Science: Challenging Classroom Realities through Teacher Education.
2013
Lehesvuori, Sami Towards Dialogic Teaching in Science: Challenging Classroom Realities through Teacher Education Jyvaskyla: University of Jyvaskyla, 2013, 87 p. (Jyvaskyla Studies in Education, Psychology and Social Research ISSN 0075-4625; 465) ISBN 978-951-39-5151-1 (nid.) ISBN 978-951-39-5152-8 (PDF) Diss. Finnish summary The aim of this study was to explore dialogic teaching in school classroom and teacher education contexts. Despite moves towards more socially-oriented and student-centred curricula, science classroom communication remains prevailingly authoritative and monologic. In order to address the dialogic gap existing in the field, within this study an intervention was developed…
Distribution of Ground Fault Current in Substations Fed by a Combined Overhead-Cable Line
2005
When a substation is fed by a combined overhead-cable transmission line, in case of a fault to ground within the substation a consistent part of the fault current flows through the cable sheaths toward the remote source and discharges into the earth at the transition station, where cables are connected to the overhead line. This phenomenon, named "fault application transfer", may result in high ground potentials at the transition station which may cause shocks and equipment damage. In this paper a simple but accurate method on modelling a combined overhead-cable line is presented, allowing the computation of the fault current transferred at the transition station. Numerical analysis shows t…
Analysis of ground fault current distribution along nonuniform multi-section lines
2008
In case of a substation supplied by a combined overhead-cable line, most of the ground fault current flows through the cable sheaths and discharges into the soil surrounding the point of discontinuity, where cables are connected to the overhead line. In the paper a new method is presented for computing the ground fault current distribution in case of feeding line consisting of two or more different sections, i.e. part overhead and part underground cable. Besides the calculation of the earth current at the fault location, the leakage current at the transit/transition stations as well as at the overhead line towers can be evaluated, in order to ensure proper safety conditions. Based on the tw…
Efficient modeling of a combined overhead cable line for grounding-system analysis
2008
Simple compact models for combined overhead-cable lines supplying a substation are presented as an extension of a previous paper for grounding system analysis. The overhead line section can be equipped with uniform or combined ground wires, whereas the cable line section can consist of coated metal sheathed cables, with/without intermediate grounding, or uncoated metal sheathed cables in continuous contact with the earth. Besides the calculation of the earth current at the faulted substation, the proposed modeling method allows the evaluation of the leakage current at the transition station, where cables are connected to the overhead line, as well as at critical overhead line towers. In thi…
Currents Distribution During a Fault in an MV Network: Methods and Measurements
2016
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighboring substations. In this paper the problem of fault current distribution is introduced, the tes…
Simple Circuit Models for Studying Global Earthing Systems
2007
The paper proposes three simple circuit models for the simulation of the behaviour of a global earthing system during different fault events. The models allow one the evaluation of the maximum earth potential rise at every possible fault location and for every possible fault event. The three considered fault events are: single-line-to-earth fault inside a MV/LV substation, double-earth-fault in a MV line, single-line-to-earth fault inside a HV/MV station. After having illustrated the hypotheses at the basis of the study, the circuit models for the three fault events are presented and a numerical example shows how to use them in order to check the "global safety" of the interconnected earthi…