Search results for "HM"
showing 10 items of 10594 documents
Uncertainty quantification in simulations of epidemics using polynomial chaos.
2012
Mathematical models based on ordinary differential equations are a useful tool to study the processes involved in epidemiology. Many models consider that the parameters are deterministic variables. But in practice, the transmission parameters present large variability and it is not possible to determine them exactly, and it is necessary to introduce randomness. In this paper, we present an application of the polynomial chaos approach to epidemiological mathematical models based on ordinary differential equations with random coefficients. Taking into account the variability of the transmission parameters of the model, this approach allows us to obtain an auxiliary system of differential equa…
Recognition of Root Canal Orifices in Video Sequences as a Future Support System During Endodontic Treatment
2009
Abstract Introduction The objective of this study was to show the practical application of computer-aided techniques for detecting root canal orifices through the access cavity using a video camera mounted on a microscope. Methods A minimum distance classification image recognition algorithm was tested in an in vitro study to assess the possibilities of computer-aided recognition of root canal orifices. A Motic DM143 digital stereo microscope (Motic Germany GmbH, Wetzlar, Germany) was used because it includes a video camera that can be connected via USB1.1 to any computer. Results The newly developed software is capable of communicating with a video camera and can automatically detect the r…
Temporally stable beta sensorimotor oscillations and cortico–muscular coupling underlie force steadiness
2022
Funding Information: Data and code are available on the Open Science Framework (OSF) at the following link: https://osf.io/4rmex/?view_only=7d17c2334ace4a0d83087bddf2a64a68. Scott Mongold, Thomas Legrand, and Mathieu Bourguignon were supported by the Fonds de la Recherche Scientifique (F.R.S.-FNRS, Brussels, Belgium; grant MIS F.4504.21). Harri Piitulainen was supported by the Academy of Finland (grants 266133, 296240, 326988, 327288 and 311877) including “Brain changes across the life-span” profiling funding to University of Jyväskylä. We thank Helge Kainulainen and Ronny Schreiber at Aalto NeuroImaging for providing technical help and the force sensor system for the study. We thank Riitta…
Surrogate data approaches to assess the significance of directed coherence: Application to EEG activity propagation
2009
This paper addresses the topic of evaluating the significance of frequency domain measures of causal coupling in multivariate time series through generation of surrogate data. The considered approaches are the traditional Fourier Transform (FT) algorithm and a new causal FT (CFT) algorithm for surrogate data generation. Both algorithms preserve the FT modulus of the original series; differences are in the phase relationships, that are completely destroyed for FT surrogates and imposed after switching off the link over the considered causal direction for CFT surrogates. The ability of the algorithms to assess causality in the frequency domain was tested using the directed coherence as discri…
Testing Frequency-Domain Causality in Multivariate Time Series
2010
We introduce a new hypothesis-testing framework, based on surrogate data generation, to assess in the frequency domain, the concept of causality among multivariate (MV) time series. The approach extends the traditional Fourier transform (FT) method for generating surrogate data in a MV process and adapts it to the specific issue of causality. It generates causal FT (CFT) surrogates with FT modulus taken from the original series, and FT phase taken from a set of series with causal interactions set to zero over the direction of interest and preserved over all other directions. Two different zero-setting procedures, acting on the parameters of a MV autoregressive (MVAR) model fitted on the ori…
A multicenter phase III prospective randomized trial of high-dose epirubicin in combination with cyclophosphamide (EC) versus docetaxel followed by E…
2011
Background: The Gruppo Oncologico Italia Meridionale 9902 trial compared four cycles of high-dose epirubicin plus cyclophosphamide (EC) with four cycles of docetaxel (Taxotere, D) followed by four cycles of EC as adjuvant treatment of node-positive breast cancer. Patients and methods: Patients were randomly assigned to EC (E 120 mg/m 2 , C 600 mg/m 2 , arm A) for four cycles or four cycles of D (100 mg/m 2 ) followed by four cycles of EC (arm B), both regimens every 21 days. Hormone receptor-positive patients were given hormonal therapy for 5 years. Primary end point was 5-year disease-free survival (DFS). Secondary objectives were overall survival (OS) and safety. Results: There were 750 p…
Guía de práctica clínica: síndrome del intestino irritable con estreñimiento y estreñimiento funcional en adultos: concepto, diagnóstico y continuida…
2016
Resumen En esta Guía de práctica clínica analizamos el manejo diagnóstico y terapéutico de pacientes adultos con estreñimiento y molestias abdominales, bajo el espectro del síndrome del intestino irritable y el estreñimiento funcional. Tienen una importante repercusión personal, sanitaria y social, afectando a la calidad de vida de los pacientes que las padecen. En el síndrome del intestino irritable con predomino del estreñimiento, este es la alteración deposicional predominante junto con dolor abdominal recurrente, hinchazón y distensión abdominal frecuente. El estreñimiento se caracteriza por la dificultad o la escasa frecuencia en las deposiciones, acompañado por esfuerzo excesivo duran…
Four-phase rhinomanometry: a multicentric retrospective analysis of 36,563 clinical measurements
2015
Rhinomanometry can still be considered as the standard technique for the objective assessment of the ven- tilatory function of the nose. Reliable technical requirements are given by fast digital sensors and modern information technology. However, the xyimaging of the pressure-flow relation typically shows loops as a sign of hysteresis, with the need for resolution of the breath in four phases. The three pillars of 4-phase rhinomanometry (4PR) are the replacement of estimations by measurements, the introduc- tion of parameters related to the subjective sensing of obstruction, and the graphical information regarding the disturbed function of the nasal valve. In a meta-analysis of 36,563 clini…
Identification of D179H, a novel missense GJB2 mutation in a Western Sicily family
2013
The main purpose of this study was to describe a novel missense mutation (p.D179H) found in a Western Sicily family and to examine the genetic and audiologic profiles of all family members by performing a GJB2 and GJB6 mutations analysis and a complete audiologic assessment. The proband was a 3-month-old infant with a congenital profound sensorineural hearing loss; direct sequencing of the GJB2 revealed the presence of a c.35delG mutation in the heterozygous state and a heterozygous G[C transition at nucleotide 535 in trans; this novel mutation, called p.D179H, resulted in an aspartic acid to histidine change at codon 179. It was also evidenced in the heterozygous state in two members of th…
Mass Output and Particle Size Distribution of Glucocorticosteroids Emitted from Different Inhalation Devices Depending on Various Inspiratory Paramet…
2002
Efficient inhalation therapy depends on successful delivery of the drug to the lung. The efficacy of drug delivery is not only influenced by the characteristics of the inhalation device, but also by the patient's handling of the device and by the inspiratory maneuver achieved through the device. We analyzed the output characteristics of three different chlorofluorocarbon (CFC)-free breath-actuated inhalers for inhaled glucocorticosteroids (BUD Turbohaler, FP Diskus/Accuhaler and HFA-BDP Autohaler, respectively). Mass output and particle size distribution of drug aerosol delivered by the inhalers were determined depending on different inhalation parameters in vitro using an Andersen cascade …