Search results for "HPGe detector"

showing 9 items of 19 documents

Equivalent detector models for the simulation of efficiency response of an HPGe detector with PENELOPE code

2019

In this work, some ‘equivalent’ models for the simulation of efficiency response of a High-Purity Germanium (HPGe) detector, installed inside a ‘low background’ bunker in the Engineering Department of the University of Palermo, were developed. The main feature was to attribute the uncertainties of the model to only one of the parameters, the dead layer of the detector, keeping unchanged the other data provided by the manufacturer. With this technique, using the Monte Carlo PENELOPE code in the 2011 version, the efficiency response was evaluated and compared with the previous one performed with MCNP5 code. The validation of equivalent models is performed by comparing the simulation results w…

PhysicsNuclear and High Energy PhysicsRadiationSettore ING-IND/20 - Misure E Strumentazione NucleariNuclear engineeringDetectorCondensed Matter PhysicsSemiconductor detectormodellingefficiencyCode (cryptography)General Materials ScienceHPGe detectorHpge detectorGamma ray spectrometryMonte Carlo
researchProduct

MCNP5 modelling of HPGe detectors for efficiency evaluation in gamma-ray spectrometry

2009

A modelling of HPGe detectors was performed through simulation with the MCNP5 Monte Carlo code. The simulation results concerning the values of the main physical parameters of the detector are in most cases different from those provided by the manufacturer. The use of “single-line” sources allows us to suitably modify the parameter values used in the detector model. For a detector model, the simulation assesses the distribution of photopeak and total efficiency for point sources, whereas for extended sources a control volume approach allows us to determine elementary efficiency behaviours. An integration of elementary efficiencies over the entire sample volume allows us to evaluate global e…

PhysicsNuclear and High Energy PhysicsRadiationgamma-ray spectrometrySettore ING-IND/20 - Misure E Strumentazione NucleariNuclear engineeringMonte Carlo methodDetectorTotal efficiencyAnalytical chemistryCondensed Matter PhysicsControl volumeSample volumeefficiencyGeneral Materials SciencePoint (geometry)HPGe detectorγ ray spectrometryHpge detectorMonte Carlo
researchProduct

The GALILEO γ-ray array at the Legnaro National Laboratories

2021

Abstract GALILEO, a new 4 π high-resolution γ -detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital read-out chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy γ -ray transitions. In this work, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

PhysicsNuclear and High Energy PhysicsSiliconbusiness.industryInstrumentationHigh-resolution γ-ray spectroscopyDetectorNeutronDAQ; Electronics; High-resolution γ-ray spectroscopy; HPGe; Neutron; SiliconSemiconductor detectorDAQOpticsData acquisitionElectronicsGalileo (vibration training)ElectronicsbusinessHpge detectorHPGeInstrumentation
researchProduct

Resolution, efficiency and stability of HPGe detector operating in a magnetic field at various gamma-ray energies

2008

Abstract The use of High Purity Germanium detectors (HPGe) has been planned in some future experiments of hadronic physics. The crystals will be located close to large spectrometers where the magnetic fringing field will not be negligible and their performances might change. Moreover high precision is required in these experiments. The contribution of magnetic field presence and long term measurements is unique. In this paper the results of systematic measurements of the resolution, stability and efficiency of a crystal operating inside a magnetic field of 0.8 T, using radioactive sources in the energy range from 0.08 to 1.33 MeV, are reported. The measurements have been repeated during sev…

PhysicsNuclear and High Energy PhysicsSpectrometerField (physics)HPGe; PANDA; Double HypernucleiPANDAResolution (electron density)DetectorHPGe detectorsGamma raychemistry.chemical_elementHPGe detectors; hypernuclear gamma-ray spectroscopy; magnetic fieldGermaniummagnetic fieldSemiconductor detectorComputational physicsMagnetic fieldNuclear physicshypernuclear gamma-ray spectroscopychemistryDouble HypernucleiHPGeNuclear ExperimentInstrumentation
researchProduct

Performance of HPGe detectors in high magnetic field

2006

A new generation of high-resolution hypernuclear gamma$-spectroscopy experiments with high-purity germanium detectors (HPGe) are presently designed at the FINUDA spectrometer at DAPhiNE, the Frascati phi-factory, and at PANDA, the antiproton proton hadron spectrometer at the future FAIR facility. Both, the FINUDA and PANDA spectrometers are built around the target region covering a large solid angle. To maximise the detection efficiency the HPGe detectors have to be located near the target, and therefore they have to be operated in strong magnetic fields B ~ 1 T. The performance of HPGe detectors in such an environment has not been well investigated so far. In the present work VEGA and EURO…

PhysicsNuclear and High Energy PhysicsSpectrometerPreamplifierPhysics::Instrumentation and DetectorsHPGe detectorsHadronDetectorFOS: Physical sciencesSemiconductor detectorMagnetic fieldNuclear physicshypernuclear gamma-spectroscopy; HPGe detectorshypernuclear gamma-spectroscopyRise timeMagnetPhysics::Accelerator PhysicsHigh Energy Physics::ExperimentNuclear Experiment (nucl-ex)Nuclear ExperimentInstrumentationNuclear Experiment
researchProduct

Development of a γ-γ-perturbed angular correlation one-detector method (1-PAC) for investigation of physico-chemical properties of matter

2002

Abstract A new method of the perturbed angular γ – γ -correlation (PAC) measurements was developed using one HPGe detector only (1-PAC). For quantifying the perturbation factor, the ratio R γ 1 + γ 2 of the summing peak composed of two cascade γ -rays (the perturbation-affected parameter) to the summing peak composed of one γ -ray and one X-ray (the perturbation non-affected parameter) was used. This method was demonstrated for the radionuclides 111 In and 111m Cd, identifying the chemical status of the radionuclides in aqueous solutions.

RadiationAqueous solutionCascadeChemistryAngular correlationChemical speciationDetectorAnalytical chemistryHpge detectorApplied Radiation and Isotopes
researchProduct

An experimental approach to efficiency calibration for gamma-ray spectrometric analysis of large air particulate filters

2013

Abstract A full-energy-peak efficiency (FEPE) calibration procedure for gamma-ray spectrometric analysis of air particulate samples collected on large filters is described herein. The experimental results are obtained for an unconventional measurement geometry, termed a “packet-sample”. The sample is obtained from a large cellulose filter (45 cm×45 cm) used to collect air particulate samples that is resized to dimensions suitable for spectrometric measurements (6 cm×6 cm×0.7 cm). To determine the FEPEs, many standards were created, i.e., some filters containing a small amount of ThO 2 and others containing a known amount of KCl. Efficiency curves obtained through best fits to experimental d…

RadiationChemistrySettore ING-IND/20 - Misure E Strumentazione NucleariDetectorGamma rayAnalytical chemistryMineralogyExperimental dataEfficiency calibration Air particulate Gamma-ray spectrometry HPGe detectorsParticulatesSemiconductor detectorFilter (large eddy simulation)CalibrationGamma ray spectrometry
researchProduct

Numerical expressions for the computation of coincidence-summing correction factors in γ-ray spectrometry with HPGe detectors

2009

Numerical expressions to compute gamma-gamma and gamma-X(K) coincidence summing corrections were deduced by using a suitable computer program and a matrix representation of a decay scheme. For point sources only full-energy peak and total efficiencies are needed. Alternatively, values of peak-to-total ratio can be introduced. For extended sources, the same expressions can be considered with the introduction of "effective efficiencies". Examples of the use of the expressions for point sources and a particulate filter sample measured with a 60% relative efficiency HPGe detector are reported.

RadiationDecay schemeComputer programSettore ING-IND/20 - Misure E Strumentazione NucleariComputationTransducersMatrix representationAnalytical chemistryReproducibility of ResultsEquipment DesignRadiation DosageCoincidence-summingSensitivity and SpecificitySample (graphics)CoincidenceComputational physicsEquipment Failure AnalysisSpectrometry GammaPoint (geometry)g-Ray spectrometryArtifactsRadiometryHpge detectorAlgorithmsMathematicsApplied Radiation and Isotopes
researchProduct

The decay of 133mXe.

2007

The decay of (133m)Xe has been re-measured using an electron-transporter spectrometer and a planar HPGe detector. The sample of (133m)Xe was produced by means of proton-induced fission using an ion-guide based on-line mass separator. The deduced K and L+M+... shell conversion coefficients, alpha(Kappa)=6.5(9) and alpha(L+M+...)=2.9(4), agree within the uncertainty limits with the theoretical values and remove the inconsistencies between the previous experimental studies of (133m)Xe.

RadiationSpectrometer010308 nuclear & particles physicsChemistryFissionAnalytical chemistrychemistry.chemical_element01 natural sciencesXenon0103 physical sciencesConversion coefficientsAtomic physicsNuclear Experiment010306 general physicsHpge detectorApplied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
researchProduct