Search results for "HPGe"

showing 3 items of 23 documents

The decay of 133mXe.

2007

The decay of (133m)Xe has been re-measured using an electron-transporter spectrometer and a planar HPGe detector. The sample of (133m)Xe was produced by means of proton-induced fission using an ion-guide based on-line mass separator. The deduced K and L+M+... shell conversion coefficients, alpha(Kappa)=6.5(9) and alpha(L+M+...)=2.9(4), agree within the uncertainty limits with the theoretical values and remove the inconsistencies between the previous experimental studies of (133m)Xe.

RadiationSpectrometer010308 nuclear & particles physicsChemistryFissionAnalytical chemistrychemistry.chemical_element01 natural sciencesXenon0103 physical sciencesConversion coefficientsAtomic physicsNuclear Experiment010306 general physicsHpge detectorApplied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
researchProduct

Radon and material radiopurity assessment for the NEXT double beta decay experiment

2015

Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, el nombre del grupo de colaboración, si le hubiere, y los autores pertenecientes a la UAM

Radon mitigationPhysics - Instrumentation and DetectorsNuclear engineeringchemistry.chemical_elementFOS: Physical sciencesRadon7. Clean energy01 natural sciencesHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)XenonCambres d'ionitzacióDouble beta decayGamma detectors (HPGe)0103 physical sciencesGamma spectroscopyNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentDetectors de radiació010308 nuclear & particles physicsIonization chambersCanfranc Underground LaboratoryMaterial radiopurityFísicaTime-Projection Chamber (TPC)Instrumentation and Detectors (physics.ins-det)Double beta decaySemiconductor detectorchemistry13. Climate actionNuclear countersEnvironmental scienceNeutrino
researchProduct

Valutazioni di efficienza di rivelatori HPGe con il codice MCNP5

2008

Sono presentate alcune simulazioni con il codice MCNP5 di rivelatori di fotoni di tipo HPGe (High Purity Germanium) per la valutazione di efficienze per alcune geometrie usualmente impiegate in misure di tipo radioprotezionistico (Marinelli beakers, a disco, etc). Il modello del rivelatore è validato mediante confronti con determinazioni sperimentali di sorgenti puntiformi calibrate di tipo “single line”, caratterizzate dalla emissione di un solo fotone gamma per disintegrazione. L’ottimizzazione è realizzata valutando in tutto il range energetico di interesse le differenze tra i valori simulati e sperimentali di efficienza, sia fotoelettrica che totale, al variare di alcuni dei parametri c…

Settore ING-IND/20 - Misure E Strumentazione NucleariEfficienza. rivelatori HPGe Monte Carlo
researchProduct