Search results for "HTN"
showing 10 items of 252 documents
UV-PHOTOMETRY WITH THE 1.2 M SCHMIDT TELESCOPE IN BALDONE
2016
TheUniversityofLatvia's Institute of astronomy possesses a collection of 22 thousand photographic plates taken by the1.2 mSchmidt telescope located at the Baldone observatory. Among others, there are 767 astronegatives in this collection obtained in 314 sky areas using the Johnson U-filter. The field of view of each negative covers 19 square degrees. The plate scale is 72”/mm. The digitizing of the UV-collection has started in June 2016 with EPSON EXPRESSION 10000XL flatbed scanner. The general aim of the digitizing is to obtain UV-magnitudes and positions of all objects registered on the plates. Up to date near a half of the UV-collection is digitized. 24 digitized MEGA program plates of t…
Revealing the structure of the lensed quasar Q 0957+561. I. Accretion disk size
2021
We thank the anonymous referee for the helpful comments, and constructive remarks on this manuscript. We thank the GLENDAMA project for making publicly available the monitoring data of Q 0957+561. C.F. gratefully acknowledges the financial support from Tel Aviv University and University of Haifa through a DFG grant HA3555-14/1. E.M. and J.A.M are supported by the Spanish MINECO with the grants AYA2016- 79104-C3-1-P and AYA2016-79104-C3-3-P. J.A.M. is also supported from the Generalitat Valenciana project of excellence Prometeo/2020/085. J.J.V. is supported by the project AYA2017-84897-P financed by the Spanish Ministerio de Economia y Competividad and by the Fondo Europeo de Desarrollo Regi…
Brightness and contrast do not affect visually induced motion sickness in a passively-flown fixed-base flight simulator
2016
Abstract Background Visually Induced Motion Sickness (VIMS) or simulator sickness is often elicited by a visual stimulus that lacks the appropriate vestibular or proprioceptive feedback. In this study, we chose to investigate the effects of brightness and contrast of the visual scene on VIMS. Hypothesis We hypothesized that visual environments differing in brightness or contrast would differentially induce VIMS. The symptoms of VIMS should be most severe for the combination of high brightness and high contrast and conversely lowest for the low brightness and low contrast condition. Methods 33 healthy subjects were tested in a fixed-base flight simulator. Each subject flew in four consecutiv…
Color- and motion-specific units in the tectum opticum of goldfish
2016
Extracellular recordings were performed from 69 units at different depths between 50 and [Formula: see text]m below the surface of tectum opticum in goldfish. Using large field stimuli (86[Formula: see text] visual angle) of 21 colored HKS-papers we were able to record from 54 color-sensitive units. The colored papers were presented for 5[Formula: see text]s each. They were arranged in the sequence of the color circle in humans separated by gray of medium brightness. We found 22 units with best responses between orange, red and pink. About 12 of these red-sensitive units were of the opponent "red-ON/blue-green-OFF" type as found in retinal bipolar- and ganglion cells as well. Most of them w…
New systems for extracting 3-D shape information from images
1993
Neural architectures may offer an adequate way to deal with early vision since they are able to learn shape features or classify unknown shapes, generalising the features of a few meaningful examples, with a low computational cost after the training phase. Two different neural approaches are proposed by the authors: the first one consists of a cascaded architecture made up by a first stage named BWE (Boundary Webs Extractor) which is aimed to extract a brightness gradient map from the image, followed by a backpropagation network that estimates the geometric parameters of the object parts present in the perceived scene. The second approach is based on the extraction of the boundary webs map …
EMI Analysis in Electrical Drives under Lightning Surge Conditions
2012
In this paper, a complete model of a power drive system including the earth electrodes is proposed to evaluate electromagnetic conducted interference due to lightning pulses. Circuit model of a power drive system is joined with a full-wave approach for the simulation of the time behavior of the grounding system. The proposed model enables to predict the electromagnetic conducted interference generated in the power drive system when lightning conditions involve the earth electrodes.
Reduced efficiency roll-off in light-emitting diodes enabled by quantum dot–conducting polymer nanohybrids
2014
We demonstrate QLEDs implementing wider active layers (50 nm) based on QD–conducting polymer nanohybrids, which exhibit a stable operational device performance across a wide range of current densities and brightness. A comparative study reveals that the significant suppression of efficiency roll-off in the high current density regime is primarily attributed to a sufficient charge carrier distribution over the wider active layer and improved charge carrier balance within QDs enabled by the hybridization of QDs with conducting polymers. Utilization of this finding in future studies should greatly facilitate the development of high performance, stable QLEDs at high current density or luminance…
Small-scale mixing processes enhancing troposphere-to-stratosphere transport by pyro-cumulonimbus storms
2007
Abstract. Deep convection induced by large forest fires is an efficient mechanism for transport of aerosol particles and trace gases into the upper troposphere and lower stratosphere (UT/LS). For many pyro-cumulonimbus clouds (pyroCbs) as well as other cases of severe convection without fire forcing, radiometric observations of cloud tops in the thermal infrared (IR) reveal characteristic structures, featuring a region of relatively high brightness temperatures (warm center) surrounded by a U-shaped region of low brightness temperatures. We performed a numerical simulation of a specific case study of pyroCb using a non-hydrostatic cloud resolving model with a two-moment cloud microphysics p…
A parametric analysis of the transient behavior of lightning protection systems
2005
The paper have the purpose of investigate the influence of different parameters to enable better understanding of the transient performance of complex lightning protection systems (LPS). Lightning discharges constitute the major source of atmospheric or natural noise that can interfere with electric and electronic installations. The electromagnetic characterisation of the LPS environment plays a fundamental role in order to prevent unwanted coupling phenomena that may generate abnormal signals, electric stresses dangerous for the insulation of electric components, disruptive discharges and danger to persons. The model, developed by the authors, is based on a field-approach: the numerical so…
Global Frequency and Geographical Distribution of Nighttime Streamer Corona Discharges (BLUEs) in Thunderclouds
2021
This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.