Search results for "Hardware_GENERAL"
showing 10 items of 57 documents
EMI Analysis in Electrical Drives under Lightning Surge Conditions
2012
In this paper, a complete model of a power drive system including the earth electrodes is proposed to evaluate electromagnetic conducted interference due to lightning pulses. Circuit model of a power drive system is joined with a full-wave approach for the simulation of the time behavior of the grounding system. The proposed model enables to predict the electromagnetic conducted interference generated in the power drive system when lightning conditions involve the earth electrodes.
Electromagnetic Full-Wave Simulation of Partial Discharge Detection in High Voltage AC Cables
2019
Partial discharge (PD) activity in the insulation system of an electrical equipment can determine the failure of the whole apparatus. PD sensors are widely used in high-voltage electrical systems as the main elements of a detecting system oriented to real time monitoring. Recently, non-invasive sensors have been proposed in industrial applications for cable and other sensitive electrical parts: they are based both on capacitive and on the electromagnetic radiating coupling. In order to assess the real performance of a new sensor produced by a high voltage AC cables manufacturer, the paper proposes electromagnetic fullwave simulation results.
Optimization of Charging Stations on a Route with Electric Buses
2019
Master's thesis Renewable Energy ENE500 - University of Agder 2019 This studyconsiders placement of electric charging stations for a public electric bus system with the intention of minimizing the charging power. This is an optimization problem where fully electric buses with opportunity charging strategy are considered.The developed strategies are proposed for an existing bus route in Oslo city, Norway. Batteryand chargingspecifications were determinedbased on a literature review. Measurements regarding velocity of the bus and altitude of the route were performed. This data where further used to determine the energy needsfor an electric bus. Four cases were formedregarding different batter…
New approach to characterisation of electric alloys under rotating magnetic flux density
1996
The computation of electrical machines using the characterisation of electric alloys proposed by several authors gives performances not verified by experiments on actual machines. By means of finite-element-method software, the authors show that the electromagnetic context where electrical alloys are built into rotating electrical machines is completely different from the actual characterisation system. A new testing device is proposed to take into account the phenomena highlighted.
Enhanced flexible algorithm for the optimization of slot filling factors in electrical machines †
2020
The continuous development in the field of industrial automation and electric mobility has led to the need for more efficient electrical machines with a high power density. The improvement of electrical machines’ slot filling factors is one of the measures to satisfy these requirements. In recent years, this topic has aroused greater interest in the industrial sector, since the evolution of the winding technological manufacturing processes allows an economically sustainable realization of ordered winding arrangements, rather than random ones. Moreover, the manufacture of electrical machines’ windings must be preceded by an accurate design phase in which it is possible to evaluate the maximu…
The Jiles Atherton Model for Description Of Hysteresis in Lithium Battery
2013
In this paper Jiles Atherton (JA) Model is used to obtain a mathematical model of the hysteresis in lithium battery. JA Model allows to describe both the hysteresis and the dynamical features of charging and discharging cycles in a lithium battery. The identification of the model is obtained by using a neural network technique developed for magnetic systems. The model is validated on some experimental tests on commercial batteries.
A composite indicator for water meter replacement in an urban distribution network
2012
In water supply management, volumetric water meter are typically used to measure users' consumption. With water meters, utilities can collect useful data for billing, assess the water balance of the system, and identify failures in the network, water theft and anomalous user behaviour. Despite their importance, these instruments are characterised by intrinsic errors that cause so-called apparent losses. The complexity of the physical phenomena associated with metering errors in aging water meters does not allow meter replacement to be guided by single parameters, such as the meter age or the total volume passed through the meter. This paper presents a meter replacement strategy based on a c…
The metrological characterization of the static meters for reactive energy in the presence of harmonic distortion
2007
For the electricity metering for billing purposes in distribution systems, the static meters are substituting the traditional inductive meters. Thus, the evaluation of the performances of such equipments is required, also in the presence of disturbances affecting the power systems. With respect to this, this paper analyzes the main aspects related to the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Particular attention is given to the reference standard meters, that are not considered by the actual in-force Standards. The analysis is supported by several experimental tests.
Static meters for the reactive energy in the presence of harmonics: an experimental metrological characterization
2009
Electricity metering plays a crucial role for all the commercial transactions on the energy market. Thus, an accurate evaluation of the performance of the electricity metering equipment is required not only in the reference operating conditions but also in the presence of disturbances affecting the power systems. As regards this matter, this paper analyzes the main aspects related to the metrological characterization of the static meters for the reactive energy in the presence of harmonic distortion. Attention is focused not only to the meters covered by the current standards but also to the meters of better accuracy and to the reference standard meters. The analysis is supported by several…
Sub-mA current measurement by means of GMR sensors and state of the art lock-in amplifiers
2015
Electric current measurement at the range of μA in integrated circuit has been traditionally carried out by micro-electronically engineered systems, such as current mirrors or charging capacitors. However, off-line, i.e., non-intrusive methods provide advantages related to size and power consumption. In this sense, giant magnetoresistance (GMR) magnetic sensors are optimal due to their sensitivity and CMOS compatibility. In this work, we make use of specifically designed CMOS GMR-based current sensors in combination with a custom electronic interface based on a low-voltage low-power lock-in amplifier, demonstrating the capability of this combination for current measurement in the range of μ…