Search results for "Harmonic analysis"
showing 5 items of 75 documents
Metrological performances of voltage and current instrument transformers in harmonics measurements
2018
In the new electrical system scenario, the increasing presence of non-linear loads and renewable energy sources makes the measurement of harmonics an essential task. The accuracy of harmonic measurement firstly depends on the used instrument transformers for voltage and current sensing. Since the behavior of instrument transformers in non-sinusoidal conditions is not always well defined, this paper presents an experimental study on the metrological performances of current and voltage instrument transformers (CTs and VTs) in the presence of harmonics. Proper tests procedures are defined and measurement setups are developed for both CTs and VTs calibration. The analysis is carried out by usin…
Current transformers effects on the measurement of harmonic active power in LV and MV networks
2011
The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …
Even harmonic pulse train generation by cross-polarization-modulation seeded instability in optical fibers
2012
International audience; We show that, by properly adjusting the relative state of polarization of the pump and of a weak modulation, with a frequency such that at least one of its even harmonics falls within the band of modulation instability, one obtains a fully modulated wave at the second or higher even harmonic of the initial modulation. An application of this principle to the generation of a 80-GHz optical pulse train with high extinction ratio from a 40-GHz weakly modulated pump is experimentally demonstrated using a nonzero dispersion shifted fiber in the telecom C band.
PQ and Harmonic Assessment Issues on Low-Cost Smart Metering Platforms: A Case Study
2020
This paper presents a feasibility study on how to implement power quality (PQ) metrics in a low-cost smart metering platform. The study is aimed at verifying the possibility of implementing PQ monitoring in distribution networks without replacing existing smart metering devices or adding new modules for PQ measurements, thus zeroing the installation costs. To this aim, an electronic board, currently used for remote energy metering, was chosen as a case study, specifically the STCOMET platform. Starting from the specifications of this device, the possibility of implementing power quality metrics is investigated in order to verify if compliance with standard requirements for PQ instruments ca…
Compensation of Nonlinearity of Voltage and Current Instrument Transformers
2019
This paper aims at characterizing and improving the metrological performances of current and voltage instrument transformers (CTs and VTs) in harmonic measurements in the power system. A theoretical analysis is carried out to demonstrate that, due to the iron core nonlinearity, CT and VT output signal is distorted even when the input signal is a pure sine wave. Starting from this analysis, a new method for CT and VT characterization and compensation is proposed. In a first step, they are characterized in sinusoidal conditions and the harmonic phasors of the distorted output are measured; in the second step, these phasors are used to compensate the harmonic phasors measured in normal operati…