Scalp, basal epidural and intravascular far-field recordings after median nerve stimulation: evidence for a separate N18a potential
2000
Far-field somatosensory evoked potentials (SSEPs) after median nerve stimulation were recorded from scalp- (Fz), epidural- (ED) and intravascular electrodes (basilar artery [Bas]) to study the nature of the controversial N18a component of the widespread N18 potential. In healthy volunteers frequently an N18a potential was recorded at Fz. Simultaneous Fz and ED recordings at the pontomesencephalic junction as well as Bas-recordings at the caudal basilar artery showed N18a components identical in latency and shape. With intravascular recordings the shapes differed between the top of the basilar artery and the caudal artery recordings. These findings support the existence of a separate N18a po…
Explaining the unique nature of individual gait patterns with deep learning
2019
Machine learning (ML) techniques such as (deep) artificial neural networks (DNN) are solving very successfully a plethora of tasks and provide new predictive models for complex physical, chemical, biological and social systems. However, in most cases this comes with the disadvantage of acting as a black box, rarely providing information about what made them arrive at a particular prediction. This black box aspect of ML techniques can be problematic especially in medical diagnoses, so far hampering a clinical acceptance. The present paper studies the uniqueness of individual gait patterns in clinical biomechanics using DNNs. By attributing portions of the model predictions back to the input …
Quantification of Myocardial Blood Flow Using Magnetic Resonance Imaging with Different accelerated Pulse Sequences
2009
The aim of this study was to compare SRTurboFLASH, SR-TrueFISP, and SR-segEPI pulse sequences using a twofold TSENSE-acceleration with regard to their use in quantification of myocardial blood flow (MBF). Six healthy volunteers were examined at 1.5T by first pass myocardial perfusion MRI at rest using all three TSENSE-accelerated pulse sequences. For absolute quantifi-cation of MBF XSIM software with the MMID4 model has been used. MBF analyses revealed significant MBF differences between SRTurboFLASH and SR-segEPI compared to SR-TrueFISP (p<0.005 and p<0.001, respectively). Differences between SRTurboFLASH and SR-segEPI were not statistically significant. The median MBF values for SR-TurboF…
Multilevel assessment of mental stress via network physiology paradigm using consumer wearable devices
2019
Mental stress is a physiological condition that has a strong negative impact on the quality of life, affecting both the physical and the mental health. For such a reason, accurate measurements of stress level can be helpful to provide mechanisms for prevention and treatment. This paper proposes a procedure for the classification of different mental stress levels by using physiological signals provided by low invasive wearable devices. 17 healthy volunteers participated in this study. Three different mental states were elicited in them: a resting condition, a stressful cognitive state, and a sustained attention task. The acquired physiological signals were: a one lead electrocardiogram (ECG)…
Reliability of automated optical determination of capillary refill time
2021
The present study is devoted to assessment of automated optical capillary refill time determination by custom developed optoelectronic device prototype. Study comprised fifteen healthy volunteers; To induce capillary refill time changes the hand position challenge was utilized. During rest conditions slight inter-subject variation was observed: T90 (0.75±0.27 s), TSTB (2.20±0.58 s) and temperature at the measurement site (32.21±1.87 Co), however during hand position challenge results were more consistent. Rising hand substantially increased, while lowering slightly decreased capillary refill time. We conclude that automated determination of refill time have high clinical potential, however …
Causal brain-heart information transfer during visual emotional elicitation in healthy subjects: Preliminary evaluations and future perspectives
2017
Complex heartbeat dynamics is known to reflect subject's emotional state, thanks to numerous links to brain cortical and subcortical regions. Likewise, specific brain regions are deeply involved in vagally-mediated emotional processing and regulation. Nevertheless, although the brain-heart interplay has been studied during visual emotion elicitation, directional interactions have not been investigated so far. To fill this gap, in this study we investigate brain-heart dynamics during emotional elicitation in healthy subjects through measures of Granger causality (GC) between the two physiological systems. Data were gathered from 22 healthy volunteers who underwent pleasant/ unpleasant affect…
Kilohertz and Low-Frequency Electrical Stimulation With the Same Pulse Duration Have Similar Efficiency for Inducing Isometric Knee Extension Torque …
2017
International audience; Objective To test the hypotheses that, as compared with pulsed current with the same pulse duration, kilohertz frequency alternating current would not differ in terms of evoked-torque production and perceived discomfort, and as a result, it would show the same current efficiency.Design A repeated-measures design with 4 stimuli presented in random order was used to test 25 women: (1) 500-microsecond pulse duration, (2) 250-microsecond pulse duration, (3) 500-microsecond pulse duration and low carrier frequency (1 kHz), (4) 250-microsecond pulse duration and high carrier frequency (4 kHz). Isometric peak torque of quadriceps muscle was measured using an isokinetic dyna…
How Idioms Are Recognized when Individuals Are “Thrown Off the Track”, “Off the Rack” or “Off the Path”: A Decision Time Experiment in Healthy Volunt…
2021
Figurative elements in language have their own particularities, including words that deviate from their generally accepted definition to amplify our language or to paraphrase an issue. It is still unclear how individuals process idioms that are figurative or ambiguous, especially when they additionally become distracted by modified idioms that are similar in appearance. In our study, 47 healthy adults (mean age of 27.3 years, SD = 2.9) participated in a decision time experiment to determine how participants recognize well-formed, genuine German idioms alongside certain idiom modifications. All participants were initially exposed to a prime on a screen. Then, they had to detect the target id…
Validation of a semi-physiological model for caffeine in healthy subjects and cirrhotic patients.
2015
The objective of this paper was to validate a previously developed semi physiological model to simulate bioequivalence trials of drug products. The aim of the model was to ascertain whether the measurement of the metabolite concentration-time profiles would provide any additional information in bioequivalence studies (Fernandez-Teruel et al., 2009a,b; Navarro-Fontestad et al., 2010). The semi-physiological model implemented in NONMEM VI was used to simulate caffeine and its main metabolite plasma levels using caffeine parameters from bibliography. Data from 3 bioequivalence studies in healthy subjects at 3 different doses (100, 175 and 400mg of caffeine) and one study in cirrhotic patients …
3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes
2000
MRI with hyperpolarized helium-3 (3He) provides high-resolution imaging of ventilated airspaces. The first aim of this 3He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired 3He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/α = 11 ms/4.2 ms/<10°). Known amounts of 3He were inhaled from a microprocessor-controlled delivery device…