Search results for "Healthy Volunteers"
showing 10 items of 219 documents
Redundant and synergistic information transfer in cardiovascular and cardiorespiratory variability
2015
In the framework of information dynamics, new tools are emerging which allow one to quantify how the information provided by two source processes about a target process results from the contribution of each source and from the interaction between the sources. We present the first implementation of these tools in the assessment of short-term cardiovascular and cardiorespiratory variability, by introducing two strategies for the decomposition of the information transferred to heart period (HP) variability from systolic arterial pressure (SAP) and respiration flow (RF) variability. Several measures based on the notion of transfer entropy (TE) are defined to quantify joint, individual and redun…
Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers
2005
Background/aim: TGDc-01 is a new, portable, transpalpebral tonometry device. The aim of this study was to evaluate the reproducibility of this method, including intraobserver and interobserver deviations, and to compare the results with those of Goldmann applanation tonometry and palpation of intraocular pressure (IOP). Methods: A total of 40 eyes of 20 healthy volunteers were included. Two independent parallel observers (1 and 2) performed three replicate measurements per eye, respectively, both using TGDc01 tonometry, one observer (3) performed three replicate measurements using Goldmann applanation tonometry, and one observer (4) measured the IOP via palpation. Intraindividual deviations…
Tidal Volume Estimation during Helmet Noninvasive Ventilation: an Experimental Feasibility Study
2019
AbstractWe performed a bench (BS) and human (HS) study to test the hypothesis that estimation of tidal volume (VT) during noninvasive helmet pressure support ventilation (nHPSV) would be possible using a turbine driven ventilator (TDV) coupled with an intentional leak single-limb vented circuit. During the BS a mannequin was connected to a lung simulator (LS) and at different conditions of respiratory mechanics, positive end expiratory pressure (PEEP) levels and leaks (30, 50 and 80 L/min). All differences were within the 95% limits of agreement (LoA) in all conditions in the Bland-Altman plot. The overall bias (difference between VT measured by TDV and LS) was 35 ml (95% LoA 10 to 57 ml), …
Light distortion of soft multifocal contact lenses with different pupil size and shape
2020
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…
Beyond the amygdala: Linguistic threat modulates peri-sylvian semantic access cortices
2015
In this study, healthy volunteers were scanned using functional magnetic resonance imaging (fMRI) to investigate the neural systems involved in processing the threatening content conveyed via visually presented “threat words.” The neural responses elicited by these words were compared to those elicited by matched neutral control words. The results demonstrate that linguistic threat, when presented in written form, can selectively engage areas of lateral temporal and inferior frontal cortex, distinct from the core language areas implicated in aphasia. Additionally, linguistic threat modulates neural activity in visceral/emotional systems (amygdala, parahippocampal gyrus and periaqueductal gr…
An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers
2021
This study aims to assess the performance of an analysis method to measure in vivo the movement speed of tear film particles post-blink as a measure of tear film spreading. Ocular surface parameter...
Dynamic Flexion Stiffness of Foot Joints During Walking
2016
Background: Dynamic stiffness can be used for studying foot pathologic abnormalities and for developing prostheses and orthoses. Although previous works have studied the role of ankle joint stiffness during gait, other foot joints have not yet been analyzed. We sought to characterize the dynamic stiffness of the ankle, midtarsal, and metatarsophalangeal joints during normal walking.Methods: Kinematics and contact data from four healthy individuals during walking were registered with a three-dimensional motion analysis system and a pressure platform. Stance phases with flexion moment-angle linear relationships were identified, and dynamic stiffnesses were calculated from the slope of their l…
Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): reference data for the trunk and application in patients with…
2013
Age- and gender-matched reference values are essential for the clinical use of quantitative sensory testing (QST). To extend the standard test sites for QST-according to the German Research Network on Neuropathic Pain-to the trunk, we collected QST profiles on the back in 162 healthy subjects. Sensory profiles for standard test sites were within normal interlaboratory differences. QST revealed lower sensitivity on the upper back than the hand, and higher sensitivity on the lower back than the foot, but no systematic differences between these trunk sites. Age effects were significant for most parameters. Females exhibited lower pressure pain thresholds (PPT) than males, which was the only si…
Pressure pain thresholds: Subject factors and the meaning of peak pressures.
2017
Background The assessment of pressure pain has become an integral part in pain research. The distribution of pressure under a plunger can be uneven. However, measurements based on conventional devices show the applied force or mean pressure, failing to take local pressure peaks into account. Our main question was whether peak pressures under the probe are responsible for pain onset. Methods A force-controlled algometer was fitted with a newly developed pressure-indicating film. Pressure pain thresholds (PPTs) of 100 healthy subjects (57 men, age 18-66 years) were assessed at 29 sites across the body. Each site was measured three times, nonconsecutively and presented in randomized order. For…
Different Genetic Expression Profiles of Oxidative Stress and Apoptosis-Related Genes in Crohn's Disease.
2018
<b><i>Background/Aims:</i></b> Increased oxidative stress and decreased immune cell apoptosis have been reported to be important factors in the pathogenesis of Crohn’s disease (CD). Our aim was to characterize the genetic expression of molecules implicated in the regulation of oxidative stress and apoptosis in peripheral white mononuclear cells of 18 healthy volunteers (controls) and 20 patients at the onset of CD (active CD [aCD]): 10 who achieved remission (inactive CD [iCD]) and 10 who did not present a complete and deep response to treatment (aCD-T). <b><i>Methods:</i></b> mRNA expression was measured by the Agena MassARRAY quantitative ge…