Search results for "Heart Valve"
showing 10 items of 138 documents
Incidence of thromboembolic complications in patients with atrial fibrillation or mechanical heart valves with a subtherapeutic international normali…
2012
Subtherapeutic international normalized ratio (INR) is frequently encountered in clinical practice, and patients with high-risk atrial fibrillation (AF) and with mechanical heart valve (MHV) with inadequate anticoagulation may be exposed to an increased risk of thromboembolic events (TE). However, there are no prospective data evaluating this risk. Consecutive patients with a history of stable anticoagulation, but with a subtherapeutic INR, were prospectively included. Data on use and dose of low-molecular weight heparin (LMWH) bridging therapy were collected. The incidence of objectively confirmed TE and of major bleeding events within 90 days after the index INR was assessed. Five hundred…
Effects of combined therapy of clopidogrel and aspirin in preventing thrombus formation on mechanical heart valves in an ex vivo rabbit model.
2002
Abstract Background: The aim of our study was to investigate the efficacy of the combination of clopidogrel and aspirin in the prevention of thrombus formation on artificial heart valves in an experimental rabbit model as compared to anticoagulation with warfarin. Methods: Studies were performed after oral administration of clopidogrel and aspirin in group I (n=9) for 5 days, after 5±2 days treatment with warfarin in group II (n=9) and without medication in group III (n=9). Leaflets from Sulzer Carbomedics bileaflet valves were placed in a flow chamber. The flow chamber was filled with blood in a continuous circulation between the carotid artery and the jugular vein. Results: In group III, …
Valve prosthesis-patient mismatch: hemodynamic, echocardiographic and clinical consequences
2011
OBJECTIVES: The purpose is to evaluate in vivo at rest and under stress conditions hemodynamic performance of the small size St. Jude Medical Regent (SJMR) prosthetic valve in patients with a body surface area (BSA) of 1.8 ± 0.11 m(2) and to define the role of valve prosthesis- patient mismatch on left ventricular mass regression following aortic valve replacement. METHODS: We evaluated 25 cases (12 males and 13 females, mean age 65.2 ± 8 years) of aortic valve replacement (17 mm SJMR in three cases and 19 mm SJMR in 22 cases). All the patients underwent at rest Doppler echocardiography before and after surgery and both basal and dobutamine stress echocardiography (DSE) at follow-up. The me…
Time interval between infective endocarditis first symptoms and diagnosis: relationship to infective endocarditis characteristics, microorganisms and…
2016
International audience; OBJECTIVE: To analyze the characteristics and outcome of infective endocarditis (IE) according to the time interval between IE first symptoms and diagnosis.METHODS: Among the IE cases of a French population-based epidemiological survey, patients having early-diagnosed IE (diagnosis of IE within 1 month of first symptoms) were compared with those having late-diagnosed IE (diagnosis of IE more than 1 month after first symptoms).RESULTS: Among the 486 definite-IE, 124 (25%) had late-diagnosed IE whereas others had early-diagnosed IE. Early-diagnosed IE were independently associated with female gender (OR = 1.8; 95% CI [1.0-3.0]), prosthetic valve (OR= 2.6; 95% CI [1.4-5…
Bicuspid aortic valve and unruptured sinus of Valsalva aneurysm, a rare association
2016
Bicuspid aortic valve (BAV) is one of the most common forms of congenital heart defect and is associated with other congenital vascular and cardiac defects. The most common comorbidity is dilation of thoracic aorta and clinical manifestations are usually related to function of the aortic valve and to other cardiovascular acquired complications. Sinus of Valsalva aneurysm (SVA) is an uncommon congenital cardiovascular anomaly and the combination of these two anomalies is very rare. Common complications are rupture and obstruction of the termination chamber due to space-occupying effect of large unruptured aneurysms. Early cardiac imaging can help limiting morbidity and mortality in these pat…
Patients with bicuspid aortic valve are likely to receive an aortic valve prosthesis during prophylactic resection of their ascending aortic aneurysm.
2015
This study aims to evaluate whether thepresence or discovery of a BAV under ATAA repair would impactthe decision-making of the surgical procedure choice.
Tumor Marker Carbohydrate Antigen 125 Predicts Adverse Outcome After Transcatheter Aortic Valve Implantation
2013
ObjectivesThis study sought to predict the value of tumor marker carbohydrate antigen 125 (CA125) before and after transcatheter aortic valve implantation (TAVI) for all-cause death and a composite endpoint of death, admission for heart failure, myocardial infarction, and stroke (major adverse cardiac events [MACE]).BackgroundRisk stratification after TAVI remains challenging. The use of biomarkers in this setting represents an unmet need.MethodsCA125 was measured in 228 patients before and after TAVI. The association with outcomes was assessed using parametric Cox regression and joint modeling for baseline and longitudinal analyses, respectively. CA125 was evaluated as logarithm transforma…
Cardiopulmonary Hemodynamic Profile Predicts Mortality After Transcatheter Tricuspid Valve Repair in Chronic Heart Failure.
2020
This study was designed to assess hemodynamic changes in response to transcatheter tricuspid valve edge-to-edge repair (TTVR) and to identify hemodynamic predictors associated with mortality.Severe tricuspid regurgitation (TR) is associated with high mortality. TTVR effectively alleviates heart failure symptoms, but comprehensive hemodynamic characterization of patients undergoing TTVR is currently lacking.This international, multicenter study included 236 patients undergoing TTVR. Data from clinical assessment, echocardiography, intraprocedural right heart catheterization, and noninvasive cardiac output measurement were analyzed. Hemodynamic predictors for mortality were identified using l…
Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
2013
Background— Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results— Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters an…