Search results for "High Resolution"
showing 9 items of 249 documents
Systematic analysis of esophageal pressure topography in high-resolution manometry of 68 normal volunteers
2013
Summary The introduction of high-resolution manometry (HRM) has been a significant advance in esophageal diagnostics. Normative values however are currently based upon a single set of published reference values, and multiple new metrics have been added over the past several years. Our goal was to provide a second set of ‘normal-values’ and to include all current metrics suggested by the 2012 Chicago classification. Sixty-eight subjects without foregut symptoms or previous surgery (median age 25.5 years, ranging from 20–58 years, 53% female) underwent esophageal motility assessment via an established standardized protocol. Normative thresholds were calculated for esophago-gastric junction (E…
Button batteries and typical swallowed foreign bodies can be differentiated in high-resolution X-Rays.
2021
Abstract Background Button battery ingestions have emerged as an increasing medical issue in recent years, especially for children. The frequent use of these energy sources in small appliances and toys is responsible for their ubiquitous occurrence in households. In addition to other possible foreign bodies, button batteries are particularly dangerous as they can cause severe complications in the aerodigestive tract. Objective The study aimed for a detailed analysis of specific radiographic identifiers of button batteries and similarly configured potential esophageal foreign bodies in high-resolution X-ray scans. Methods A selection of potentially hazardous button batteries - in cases of in…
Hochauflösende Dünnschicht-CT zum präoperativen Staging beim Rektumtumor: Vergleich mit der endo-luminalen Sonographie und der Histologie
1990
Rectal carcinomas are amongst the most common malignant tumours. The aim of this work was to determine whether high resolution CT with thin sections (1 mm) can provide satisfactory delineation of perirectal tumour infiltration. Correct determination of local tumour spread was possible in four out of nine patients and distinction between those tumours confined to the rectal wall and those infiltrating the perirectal tissues was possible in four out of eight patients.
Intravaskuläre Sonographie: Erste klinische Ergebnisse
1991
Intravascular ultrasound is a new diagnostic modality which, for the first time, provides high resolution images of the vessel wall. 91 intraluminal ultrasound studies were performed in 50 patients during the course of 55 diagnostic and therapeutic catheterizations. A F-6 ultrasound catheter (20 MHz) was used. The method is an easily and rapidly performed addition to angiography. Changes in vessel walls (arteriosclerosis, dissection, tumour infiltration) can be readily diagnosed and their extent can be accurately described. The ability to determine luminal cross sectional area is particularly helpful for planning and performing therapeutic interventions.
High-resolution laser spectroscopy of long-lived plutonium isotopes
2017
Long-lived isotopes of plutonium were studied using two complementary techniques, high-resolution resonance ionisation spectroscopy (HR-RIS) and collinear laser spectroscopy (CLS). Isotope shifts have been measured on the $5f^67s^2\ ^7F_0 \rightarrow 5f^56d^27s\ (J=1)$ and $5f^67s^2\ ^7F_1 \rightarrow 5f^67s7p\ (J=2)$ atomic transitions using the HR-RIS method and the hyperfine factors have been extracted for the odd mass nuclei $^{239,241}$Pu. Collinear laser spectroscopy was performed on the $5f^67s\ ^8F_{1/2} \rightarrow J=1/2\; (27523.61\text{cm}^{-1})$ ionic transition with the hyperfine $A$ factors measured for $^{239}$Pu. Changes in mean-squared charge radii have been extracted and s…
Potential combined effects of maternal smoking and coffee intake on foetal death within the Danish National Birth Cohort
2018
Background: Several studies have linked coffee intake and smoking to foetal death, but a possible interaction between both exposures remains unknown.Methods: We studied, within the Danish National Birth Cohort, the potential interaction between smoking and coffee drinking while pregnant on the risk of foetal (early and late) death. The study included 90 086 pregnant women, with information about their smoking habit and coffee intake in early pregnancy, and several potential confounding factors. Interaction was studied by calculating both the hazard ratio (HR) in Cox's regression (linear and smoothed restricted cubic spline) and the interaction contrast ratio (ICR).Results: Women who neither…
Characterization of Supersonic Gas Jets for High-Resolution Laser Ionization Spectroscopy of Heavy Elements
2018
© 2018 authors. Published by the American Physical Society. Published by the American Physical Society under the terms of the »https://creativecommons.org/licenses/by/4.0/» Creative Commons Attribution 4.0 International license. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI. The method of laser spectroscopy in supersonic gas jets was proposed for high-resolution and high-efficiency in-gas laser ionization and spectroscopy studies of short-lived nuclei. The flow properties of such supersonic gas jets have been characterized under off-line conditions. Planar laser-induced fluorescence spectroscopy of s…
High-resolution spectroscopy and analysis of the ν4 band of 80SeF6
2001
Abstract The Fourier-transform spectrum of the ν4 bending region of 80 SeF 6 around 435 cm −1 has been recorded at a temperature of 217 K with a resolution of 2.3×10 −3 cm −1 . This fundamental has been analyzed using the set of programs called highly spherical top data system (HTDS). Altogether 958 transitions were assigned and fitted with an rms of 0.0003 cm −1 . The effective Hamiltonian was developed up to the fourth order. Parameters and simulations are presented. The ν4 band center is located at 435.099 cm −1 .
High-Frequency and Ultra-High Frequency Ultrasound: Musculoskeletal Imaging up to 70 MHz
2020
AbstractMusculoskeletal (MSK) ultrasound has well-established advantages, able to investigate very small structures with high resolution and a quick and real-time dynamic evaluation with the possibility of contralateral comparison. Thus ultrasound has kept its own almost exclusive fields of application in daily clinical practice, and it is considered the first-level imaging technique to assess tendons, bursae, and capsuloligamentous structures of small peripheral joints as well as peripheral nerves. Up to now, however, clinical MSK ultrasound imaging could not go beyond the first 1 to 2 cm under the skin, using high-frequency probes up to 18 to 20 MHz with spatial resolution just below mill…