Search results for "Hirudins"

showing 2 items of 2 documents

Recombinant hirudin as a periprocedural antithrombotic in coronary angioplasty for unstable angina pectoris

1996

Percutaneous transluminal coronary angioplasty is often complicated by thrombotic abrupt vessel closure in patients with unstable angina pectoris. The present multicentre trial was performed to determine the feasibility of two-dose regimens of recombinant hirudin (r-hirudin) compared to standard heparin in patients undergoing coronary angioplasty for unstable angina, and to investigate the effects of the different treatment regimen on markers of coagulation activation. At five participating centres, 61 patients were randomly enrolled in one of two sequential groups of r-hirudin (group 1: 0.3 mg.kg-1 i.v. bolus, 0.12 mg.kg-1.h-1 i.v. infusion; 21 patients; group 2: 0.5 mg.kg-1 i.v. bolus, 0.…

Adultmedicine.drug_classmedicine.medical_treatmentHirudinEnzyme-Linked Immunosorbent AssayAnginaFibrinolytic AgentsmedicineHumansAngina UnstableAngioplasty Balloon CoronaryInfusions IntravenousBlood CoagulationAgedBlood coagulation testDose-Response Relationship Drugmedicine.diagnostic_testHeparinUnstable anginabusiness.industryAnticoagulantThrombinAnticoagulantsPercutaneous coronary interventionHeparinHirudinsMiddle Agedmedicine.diseaseRecombinant ProteinsAnesthesiaPartial Thromboplastin TimeDrug MonitoringCardiology and Cardiovascular MedicinebusinessBiomarkersmedicine.drugPartial thromboplastin timeEuropean Heart Journal
researchProduct

Evaluation of an automated chromogenic substrate assay for the rapid determination of hirudin in plasma.

1995

Abstract A fully mechanized chromogenic substrate assay method for the rapid and specific determination of recombinant hirudin (r-hirudin) in citrated plasma on clinical chemistry analyzers (Hitachi 911 and Cobas Mira) is described. In a first step, 12 μl sample volume is mixed with the chromogenic substrate. Due to the almost immediate action of hirudin the inhibitory reaction and the cleavage of the substrate is started simultaneously when bovine thrombin is added in excess. This excludes interferences by antithrombin III or heparin cofactor II. The change in absorbance/min is recorded at 405 nm. The measuring range is about 0.2 – 4.0 mg/l r-hirudin on both analyzers. Precision is charact…

MaleHirudinEnzyme-Linked Immunosorbent AssayAbsorbanceAutomationReference ValuesBlood plasmamedicineAnimalsHumansHeparin cofactor IIChromatographyChemistryChromogenicAntithrombinThrombinSubstrate (chemistry)Chromogenic substrate assayHematologyHirudinsMiddle AgedRecombinant ProteinsChromogenic CompoundsCalibrationCattleColorimetryFemalePartial Thromboplastin TimeOligopeptidesmedicine.drugThrombosis research
researchProduct