Search results for "Hope"
showing 10 items of 2928 documents
Effect of lumbar disc replacement on the height of the disc space and the geometry of the facet joints: a cadaver study.
2010
In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation sofware applied to CT scans before and after instrumentation. After disc replacement the mean lumbar disc height was doubled (p < 0.001). The mean angle of lordosis and the facet joint space increased by a statistically significant extent (p < 0.005 and p = 0.006, respectively). By contrast, the mean facet joint overlap was significantl…
Surgical repair of acute Achilles tendon rupture with an end-to-end tendon suture and tendon flap.
2015
Abstract Background Achilles tendon ruptures are becoming more common. Complications after open or minimally invasive surgery are: recurrent rupture (2–8%), wound breakdown, deep infections, granuloma, and fistulas. The authors expose their experience with a personal technique. Materials In 8 patients with acute rupture of Achilles tendon the surgery was performed at least 25 days after trauma. Clinical exam and MR demonstrated in all case a total lesion of tendon. After a posterolateral skin incision the tendon stumps were debrided and suture in end-to-end fashion. A tendon flap was harvested from the proximal part of the tendon, in order to protect and reinforce the suture itself. A plast…
Rates of Upper Facet Joint Violation in Minimally Invasive Percutaneous and Open Instrumentation: A Comparative Cohort Study of Different Insertion T…
2017
Background Minimally invasive pedicle screw placement may have a higher incidence of violation of the superior cephalad unfused facet joint. Study Aims We investigated the incidence and risk factors of upper facet joint violation in percutaneous robot-assisted instrumentation versus percutaneous fluoroscopy-guided and open transpedicular instrumentation. Methods A retrospective study including all consecutive patients who underwent lumbar instrumentation, fusion, and decompression for spondylolisthetic stenosis and degenerative disk disease was conducted between January 2012 and January 2016. All operations were performed by the same surgeon; the patients were divided into three groups acc…
Walking and Running Require Greater Effort from the Ankle than the Knee Extensor Muscles.
2016
The knee and ankle extensors as human primary antigravity muscle groups are of utmost importance in a wide range of locomotor activities. Yet, we know surprisingly little about how these muscle groups work, and specifically, how close to their maximal capacities they function across different modes and intensity of locomotion. Therefore, to advance our understanding of locomotor constraints, we determined and compared relative operating efforts of the knee and ankle extensors during walking, running, and sprinting.Using an inverse dynamics biomechanical analysis, the muscle forces of the knee and ankle extensors during walking (1.6 m·s), running (4.1 m·s), and sprinting (9.3 m·s) were quant…
Micromechanical Properties and Collagen Composition of Ruptured Human Achilles Tendon
2012
Background:The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive.Hypothesis:Ruptured human Achilles tendon displays inferior biomechanical properties and altered collagen composition compared with noninjured tendon.Study Design:Controlled laboratory study.Methods:Biopsy specimens were obtained at the rupture site and the noninjured part of the tendon (internal controls) in 17 patients with acute Achilles tendon rupture. Age- and weight-matched human cadaveric Achilles tendons (external controls) were also obtained. Tendon samples were tested micromechanica…
Movement Variability Increases With Shoulder Pain When Compensatory Strategies of the Upper Body Are Constrained
2017
[DE] This cross-sectional study analyzed the influence of chronic shoulder pain (CSP) on movement variability/kinematics during humeral elevation, with the trunk and elbow motions constrained to avoid compensatory strategies. For this purpose, 37 volunteers with CSP as the injured group (IG) and 58 participants with asymptomatic shoulders as the control group (CG) participated in the study. Maximum humeral elevation (Emax), maximum angular velocity (Velmax), variability of the maximum angle (CVEmax), functional variability (Func_var), and approximate entropy (ApEn) were calculated from the kinematic data. Patients' pain was measured on the visual analogue scale (VAS). Compared with the CG, …
Cementless total hip replacement with subtrochanteric femoral shortening for severe developmental dysplasia of the hip.
2003
Total joint replacement in patients suffering from developmental dysplasia of the hip poses specific technical difficulties due to insufficient bone stock at the site of the original and secondary acetabulum and a narrow, cranially displaced proximal femur. Twelve hips with severe congenital dislocation (4 Crowe type II, 5 type III, 3 type IV) were treated with cementless, porous structured total hip replacement. The cup was implanted at the anatomic height, a femoral segment was resected below the minor trochanter to reduce the femoral component in all cases. One femoral component was exchanged for a longer stem after 2 months due to insufficient fit and fill. After a mean follow-up of 5.1…
A ten-year follow-up of the Reflection cementless acetabular component.
2008
We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…
Monitoring bone growth using quantitative ultrasound in comparison with DXA and pQCT.
2008
Quantitative ultrasound (QUS) is a safe, inexpensive, and nonradiation method for bone density assessment. QUS correlates with, and predicts fragility fractures comparable to, dual-energy X-ray absorptiometry (DXA)-derived bone mineral density (BMD) in postmenopausal women. However, its validity in monitoring bone growth in children is not well understood. Two hundred and fifty-eight 10-13 yr pubertal girls and 9 37-43 yr adults without diseases or history of medications known to affect bone metabolism were included in the 2-yr prospective study. Calcaneal broadband ultrasound attenuation (cBUA) was assessed using QUS-2 (Quidel, Santa Clara, CA), speed of sound of tibial shaft (tSOS) using …
Effects of pregnancy on lumbar motion patterns and muscle responses.
2018
The kinematics of the lumbar region and the activation patterns of the erector spinae muscle have been associated with the genesis of low back pain, which is one of the most common complications associated with pregnancy. Despite the high prevalence of pregnancy-related low back pain, the biomechanical adaptations of the lumbar region during pregnancy remain unknown.This study analyzes lumbar spine motion and the activation pattern of the lumbar erector spinae muscle in healthy pregnant women.A case-control study.The study involved 34 nulliparous women (control group) and 34 pregnant women in the third trimester (week 36 ± 1).We recorded the parameters of angular displacement of the lumbar …