Search results for "Hope"
showing 10 items of 2928 documents
Influence of sutures configuration on the strength of tendon-patch joints for rotator cuff tears treatment
2019
Abstract Purpose Massive rotator cuff tears are common in the aging population. The incidence of failed rotator cuff repairs is still quite high, especially in the treatment of full-thickness tears or revision repairs. In this context, natural and synthetic meshes can be used as augmentation scaffolds or as devices to close the gap between a retracted tendon and the bone. The purpose of this work is to evaluate the ultimate tensile strength of different tendon-patch joints in order to consider their use in the treatment of massive cuff tears. Materials and methods Porcine tendons and a synthetic low-density polypropylene mesh have been used. A preliminary study on the tensile strength of te…
Enhanced prolylhydroxylase activity in the posterior annulus fibrosus of canine intervertebral discs following long-term running exercise
2010
The effect of long-term excercise on the intervertebral disc collagen concentration (hydroxyproline), collagen-synthesizing enzymes (prolyl-4-hydroxylase, PH, and galactosyl-hydroxylysyl glucosyltransferase, GGT) and hydroxypyridinium crosslinks was studied in ten female beagle dogs. The dogs were run on a treadmill for 1 year starting at the age of 15 weeks. The daily running distance was gradually increased to 40km, which distance the dogs ran for the final 15 weeks. Ten untrained dogs from the same breeding colony served as controls. The nucleus pulposus and anterior and posterior halves of the annulus fibrosus of C2-3, T10-12, L4-5 disc segments were analysed. Crosslinks were measured f…
Biomechanical Analysis of a New Elbow Prosthesis
2019
Total elbow arthroplasty (TEA) is an effective and frequently used treatment for patients with debilitating elbow pathology. Total elbow prostheses have lagged behind those of the knee, hip and shoulder for different reasons, such as the high failure rate of the early designs. Concern remains regarding the longevity of TEA implants, especially in younger patients. The main cause of revision of the implant is usually related to the phenomenon of aseptic loosening mainly due to the cement-bone interface failure. Aim of this work is the biomechanical analysis of a new elbow prosthesis to investigate the mechanical behaviour at the cement-bone interface. For this reason, a musculoskeletal model…
Kinematics of the ulna during pronation and supination in a cadaver study: implications for elbow arthroplasty
2003
Objective. Aim of this study was to exactly describe and quantify kinematics of the ulna during pro- and supination. Design. Biomechanical study in fresh frozen cadavers. Background. A previous MRI study revealed a varus/valgus motion of the ulna averaging 7.1° during pro-/supination. Axial rotation, however, could not be quantified. Methods. Sixteen arms were examined in a new apparatus that fixed the humerus on a template and allowed forearm rotation. Motion of a Kirschner wire placed in the ulna was recorded in steps of 30° by two perpendicularly arranged charge coupled device cameras during pro- and supination. Results. From supination to pronation the ulna showed a semi-lunar evasive m…
Improving the cementation of the tibial component in knee arthroplasty : a study of four techniques in the cadaver.
2021
Aims The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray. Methods In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and mea…
Die Sonographie der Lendenwirbelsäule und des lumbosakralen Überganges - Sonoanatomie und Möglichkeiten der sonographisch gesteuerten Facettengelenks…
2008
QUESTION Is sonography helpful in facet joint infiltration of the lumbar spine? METHOD The sonoanatomy of the lumbar spine and the of lumbosacral junction was examined and described in a skeleton and in 10 volunteers. One representative cross section and 3 longitudinal sections were defined. According to these results (no neurological symptoms) the possibilities of ultrasound guided infiltration of the facet joints was examined in 78 patients (36 female, 42 male, average age 55 y., 38-78 y.) with chronic low back pain and increase of pain by hyperextension. 5 ml Carbostesin partially in combination with steroids were applied to each joint. In all cases the tip of the syringe could be placed…
Zur Diagnostik der transitorischen Osteoporose der Hüfte und deren Darstellbarkeit in der MR-Tomographie
2008
Magnetic resonance (MR) imaging may distinguish transient osteoporosis of the hip from more severe hip diseases. 12 patients with transient osteoporosis of the hip underwent MR imaging. The initial and follow-up studies included T1- and T2-weighted images in coronal, transverse or sagittal planes. There were revealed 3 stages: diffuse-, focal-, and residual stage. This syndrome is characterized by hip pain, limping, and osteoporosis of the femoral head with preservation of the joint space. The clinical symptoms and abnormalities on MR images disappeared completely within 6-10 months.
The distribution of cartilage thickness in the knee-joints of old-aged individuals -- measurement by A-mode ultrasound.
1997
Abstract Objective. To provide data on the normal distribution of cartilage thickness in the knee joints of old-aged individuals. Design. The accuracy and reproducibility of cartilage thickness measurements were evaluated with A-mode ultrasound, and the cartilage thickness distribution was examined throughout both knee joints of nine individuals aged between 62 and 94 yr. Background. Data on the variation of cartilage thickness in the joint surfaces are relevant for the design of computer models of diathrodial joints and for surgical and arthroscopic procedures, particularly the calculation of cartilage material properties from indentation tests. Methods. A 12.5 MHz A-mode ultrasound transd…
The impact of multilevel surgery on functional abilities and participation in adolescents with cerebral palsy (CP)
2013
but not significant decrease in RT group. Timing of pKFSw, range of knee flexion and knee flexion velocity improved after surgery but tended to deteriorate over the years in either group. Discussionandconclusions:The results of thepresent study for the first time suggest that the influences of proximal RF release on DRFT effects on the knee joint are negligible. Two possible explanations shouldbe considered. First, thefindingsmaybe explainedby a permanent eliminationofRF functionon thekneeafterDRFT,which would be unaffected by proximal release and would underline the efficiency of DRFT. Secondly, surgery in the proximal part does not influence the distal part. This would represent a new imp…
Impaired geometric properties of tibia in older women with hip fracture history.
2007
This study evaluated side-to-side differences in tibial mineral mass and geometry in women with previous hip fracture sustained on average 3.5 years earlier. Both tibial mineral mass and geometry were found to be reduced in the fractured leg. INTRODUCTION: The purpose of this study was to evaluate side-to-side differences in tibial mineral mass and geometry after hip fracture and to assess the determinants of such differences. METHODS: Thirty-eight 60- to 85-year-old women with a previous hip fracture and 22 same-aged control women without fractures participated in the study. Bone characteristics of the distal tibia and tibial shaft of both legs were assessed using pQCT in order to compare …