Search results for "Humerus"

showing 10 items of 50 documents

Frozen shoulder: a sympathetic dystrophy?

2000

Diagnostic and clinical features of the frozen shoulder syndrome and the Sudeck syndrome are similar in many aspects. Radioisotope bone scan shows an increased uptake in affected areas in both diseases, while native radiographs show a progressive demineralisation. Measurement of bone mineral density (BMD) by quantitative digital radiography objectified these local decalcification processes in an early stage of the frozen shoulder syndrome; 10 of 12 patients with primary frozen shoulder had BMD decreases greater 21% in the humeral head of the affected shoulder compared to the non-affected side. In the immobilised control group with degenerative changes of the rotator cuff, calcifying tendini…

musculoskeletal diseasesMalemedicine.medical_specialtyBone densityAbsorptiometry PhotonBone DensityArthropathymedicineHumansOrthopedics and Sports MedicineHumerusRotator cuffBone mineralbusiness.industryFrozen shoulderGeneral MedicineHumerusMiddle Agedmedicine.diseaseSurgeryReflex Sympathetic Dystrophymedicine.anatomical_structureOrthopedic surgeryUpper limbSurgeryFemalebusinessArchives of orthopaedic and trauma surgery
researchProduct

The Shoulder Girdle

2000

The shoulder girdle is an anatomically complex structure consisting of the scapula, clavicula, proximal humerus, and their articular connections. The wide range of motion is provided by the glenohumeral joint and the two shoulder girdle joints, the acromioclavicular and sternoclavicular joints.

musculoskeletal diseasesProximal humerusbusiness.industryAnatomymusculoskeletal systemmedicine.anatomical_structureScapulaShoulder girdlemedicineRotator cuffRange of motionbusinesshuman activitiesJoint (geology)
researchProduct

Kinematics of the ulna during pronation and supination in a cadaver study: implications for elbow arthroplasty

2003

Objective. Aim of this study was to exactly describe and quantify kinematics of the ulna during pro- and supination. Design. Biomechanical study in fresh frozen cadavers. Background. A previous MRI study revealed a varus/valgus motion of the ulna averaging 7.1° during pro-/supination. Axial rotation, however, could not be quantified. Methods. Sixteen arms were examined in a new apparatus that fixed the humerus on a template and allowed forearm rotation. Motion of a Kirschner wire placed in the ulna was recorded in steps of 30° by two perpendicularly arranged charge coupled device cameras during pro- and supination. Results. From supination to pronation the ulna showed a semi-lunar evasive m…

musculoskeletal diseasesanimal structuresElbowBiophysicsUlnaForearmCadaverSupine PositionmedicineHumansPronationOrthopedics and Sports MedicineKirschner wireHumerusArthroplasty Replacementbiologybusiness.industryUlnaAnatomymusculoskeletal systembiology.organism_classificationBiomechanical Phenomenabody regionsValgusmedicine.anatomical_structureCoronal planebusinessBone WiresClinical Biomechanics
researchProduct

Morphomechanics of the humero-ulnar joint: I. Joint space width and contact areas as a function of load and flexion angle

1995

BACKGROUND Previous studies have shown that the trochlear notch is deeper than necessary for an exact fit with the humerus. However, humero-ulnar joint space width and contact areas have so far not been quantified for variations in the load and angle of flexion. METHODS Six fresh cadaveric specimens were investigated at 30 degrees, 60 degrees, 90 degrees, and 120 degrees of flexion and at loads of 25 and 500 N, simulating resisted elbow extension. The joint space width and contact were determined, using polyether casting material. RESULTS At 25 N all joints made contact in the ventral and dorsal aspects of the articular surfaces, whereas in the depth of the trochlear notch the joint space w…

musculoskeletal diseasesmedicine.medical_specialtyElbowGeometrymedicine.disease_causeAgricultural and Biological Sciences (miscellaneous)Weight-bearingSurgerymedicine.anatomical_structureTrochlear notchPosition (vector)medicineHumerusAnatomyCadaveric spasmRange of motionJoint (geology)MathematicsThe Anatomical Record
researchProduct

Optimal positioning of the humeral component in the reverse shoulder prosthesis.

2014

Total reverse shoulder arthroplasty is becoming more and more the standard therapeutic practice for glenohumeral arthropathy with massive lesions of the rotator cuff. The biomechanical principle of this prosthesis is represented by the reversion of the normal anatomy of the shoulder joint. This non-anatomical prosthesis leads to a medialization of the rotation centre of the glenohumeral joint and also to a distalization of the humeral head. All that causes a deltoid tension increasing so allowing a larger abduction of the arm. Main complications of the reverse shoulder prosthesis are due to the joint instability, the scapular notching and the wear of the polyethylene insert. The main goal o…

musculoskeletal diseasesmedicine.medical_specialtyFEM analysesmedicine.medical_treatmentReplacementDeltoid curveProsthesis DesignProsthesisArthroplastyArthropathymedicineHumansOrthopedics and Sports MedicineHumerusRotator cuffArthroplasty ReplacementSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeTotal reverse shoulder arthroplasty Intrinsic stability FEM analyses Polyethylene wear Stability ratioFEM analyses; Intrinsic stability; Polyethylene wear; Stability ratio; Total reverse shoulder arthroplasty; Arthroplasty Replacement; Humans; Humerus; Prosthesis Design; Shoulder Joint; Orthopedics and Sports Medicine; Surgery; Medicine (all)business.industryShoulder JointMedicine (all)Intrinsic stabilityHumerusShoulder Prosthesismedicine.diseaseArthroplastySurgerymedicine.anatomical_structurePolyethylene wearStability ratioTotal reverse shoulder arthroplastySurgeryShoulder jointbusinesshuman activitiesMusculoskeletal surgery
researchProduct

Primäre Ellenbogenprothese bei distalen Humerustrümmerfrakturen

2004

The use of hip- and shoulder arthroplasty in elderly patients for grossly displaced intraarticular fractures is being more and more accepted. Total elbow replacement (TER) has not been considered as an option for the treatment of extensively comminuted fractures of the distal humerus because surgeons feel the outcome is not predictable after TER generally. On the basis of a Medline literature research of this issue and the documented results based on the improvement of the designs of the implants, operative technique and the selection of patients, TER has a definite role in the treatment of some fractures of the distal humerus. We retrospectively reviewed forty-nine acute distal humeral fra…

musculoskeletal diseasesmedicine.medical_specialtyOsteosynthesisbusiness.industrymedicine.medical_treatmentElbowDistal humerusArthroplastyProsthesisSurgerymedicine.anatomical_structuremedicineSurgeryHumerusIn patientComplicationbusinessAktuelle Traumatologie
researchProduct

Total Elbow Replacement as Primary Treatment for Complex Fractures of the Distal Osteopenic Humerus

2003

Background: The use of hip and shoulder arthroplasty in elderly patients for grossly displaced intraarticular fractures is becoming more and more accepted. Total elbow replacement (TER) has not been considered an option for the treatment of extensively comminuted fractures of the distal humerus because surgeons feel the outcome is generally not predictable after TER. Evaluation of TER: On the basis of a MEDLINE literature search of this issue and the documented results based on the improvement of implant designs, operative technique and patient selection, TER has a definite role in the treatment of some fractures of the distal humerus.

musculoskeletal diseasesmedicine.medical_specialtySports medicinebusiness.industrymedicine.medical_treatmentHumerus fractureDistal humerusfood and beveragesmusculoskeletal systemmedicine.diseaseArthroplastyElbow replacementSurgerymedicine.anatomical_structuremedicineSurgeryHumerusPrimary treatmentImplantbusinesshuman activitiesEuropean Journal of Trauma
researchProduct

Aston Medical Duocentric® Reversed Prosthesis: Proposition of New Glenoid Component Design to Prevent Scapular Neck Notching

2015

Medialization of the center of rotation in reverse shoulder arthroplasty (RSA) results in greater excursion of the proximal humerus especially in adduction leading to a mechanical conflict against the neck of the scapula, thus creating a specific complication: scapular notching, in up to 90 % of RSA. We describe our third generation of RSA in Dijon, the Duocentric prosthesis. This prosthesis provides a new proposition to prevent the notching problem with an inferior overhang integrated to the glenoid baseplate. Such an inferior extension prevents the malpositioning of the hemisphere and resurfaces the “critical zone” preventing notching.Phenomenon while a smaller neck-shaft angle on the hum…

musculoskeletal diseasesmedicine.medical_specialtybusiness.industrymedicine.medical_treatmentScapular notchingmusculoskeletal systemArthroplastyProsthesisSurgerymedicine.anatomical_structureNotchingScapulaEpiphysismedicineHumerusbusinessInstant centre of rotation
researchProduct

Distal Humerus Fractures

2014

Distal humerus fractures display seldom but severe injuries because of the complex distal humerus anatomy and often comminuted fracture types. They account for approximately 2–3 % of all fractures and for 17–30 % of fractures around the elbow. In younger patients, there is a predominance among males. The mechanism of accident is mostly a high-energy trauma in this population. In contrast, among elderly patients, distal humerus fractures concern mostly women with osteoporotic bone. Fractures are caused by a low-energy trauma such as a fall from standing height onto the outstretched or slightly flexed arm. These fractures are often severely comminuted. Because of the thin soft tissue envelope…

musculoskeletal diseasesmedicine.medical_specialtyeducation.field_of_studybusiness.industryElbowPopulationDistal humerusSoft tissueAnatomymusculoskeletal systemmedicine.diseaseSurgerymedicine.anatomical_structuremedicine.arterymedicineOsteoporotic boneHeterotopic ossificationBrachial arteryeducationbusinessFracture type
researchProduct

Shoulder replacement in the treatment of pluri-fragmentary and displaced fractures of the proximal humerus: our experience

2011

shoulder replacement proximal humerusSettore MED/33 - Malattie Apparato Locomotore
researchProduct