Search results for "Humidity"
showing 10 items of 291 documents
Powder X-Ray Diffraction Investigation of Xylazine Hydrochloride Solid Phase Transformation Kinetics
2013
The kinetics of the solid-state phase transformation of xylazine hydrochloride form X to A has been investigated using powder X-ray diffraction and differential thermal analysis. Three different kinetic models have been used to describe transition kinetics: the Avrami–Erofeev equation, the Cardew equation, and the methodology for simulation of solid-state phase transition kinetics by the combination of nucleation and nuclei growth processes. The latter has been recently developed and has been tested in this paper for the case of a real solid-state transition. The relative humidity, mechanical pressure, temperature, and sample-preparation effect on phase-transition kinetics have been investi…
Water vapor sensors based on the swelling of relief gelatin gratings
2015
We report on a novel device to measure relative humidity. The sensor is based on surface diffraction gratings made of gelatin. This material swells and shrinks according to the content of water vapor in air. By sending a light beam to the grating, diffracted orders appear. Due to the gelatin swelling or shrinking, first order intensity changes according to the relative humidity. Calibration curves relating intensity versus relative humidity have been found. The fabrication process of diffraction gratings and the testing of the prototype sensing devices are described.
Water Vapor Sensors Based on the Swelling of Relief Gelatin Gratings: Recent Advances and Development
2021
We report on a novel device to measure relative humidity. Materials used in the measurement of relative humidity are of different kinds. The sensor is based on surface diffraction gratings made of gelatin. This material swells and shrinks according to the content of water vapor in air. By sending a light beam to the grating, diffracted orders appear. Due to the gelatin swelling or shrinking, first order intensity changes according to the relative humidity. Calibration curves relating intensity versus relative humidity have been found. The fabrication process of diffraction gratings and the testing of the prototype sensing devices are described.
Surface soil humidity retrieval using remote sensing techniques: a triangle method validation
2010
Soil humidity plays a key-role in hydrological and agricultural processes. In the rainfall-runoff processes the knowledge of its spatial distribution is fundamental to accurately model these phenomena. Furthermore in agronomy and agricultural sciences, assessing the water content of the root zone is required in order to optimize the plant productivity and to improve the irrigation systems management. Despite the importance of this variable the in situ measurements techniques based on Time Domain Reflectometry (TDR) or on the standard thermo-gravimetric methods, are neither cost-effective nor representative of its spatial and temporal variability. Indirect estimations via Earth Observation (…
Extinction and optical depth of contrails
2011
[1] One factor limiting the understanding of the climate impact from contrails and aircraft induced cloud modifications is the accurate determination of their optical depth. To this end, 14 contrails were sampled for 2756 s with instruments onboard the research aircraft Falcon during the CONCERT (CONtrail and Cirrus ExpeRimenT) campaign in November 2008. The young (<10 min old) contrails were produced by 9 commercial aircraft with weights of 47 to 508 t, among them the largest operating passenger aircraft, the Airbus A380. The contrails were observed at temperatures between 214 and 224 K and altitudes between 8.8 and 11.1 km. The measured mean in-contrail relative humidity with respect to i…
Risks of mould growth in different building structures
2014
In the current paper the impact of real Latvian climate conditions on a variety of building constructions is inspected. The influence of the humidity on buildings’ sustainability in three different building units has been appraised. Condensate risks in a multi-layer wall are analyzed by transient outdoor climatic conditions. Risks of mould growth are discussed in detail taking into account the properties of building materials, dependence of humidity on temperature and season. The effect of vapour barrier is analyzed from several aspects. Theoretical analysis has been done based on real test stands built in Riga. Some experimental results are obtained.
Air quality and relative humidity in commercial aircrafts: an experimental investigation on short-haul domestic flights
2013
Abstract Nowadays the achievement of a comfortable environment in aircraft cabins is a factor of paramount importance in air travel business competition; on the other hand, the need of reducing the propulsion fuel cost has driven the airline companies to adopt air handling systems that may reduce the levels of thermal comfort and air quality inside the cabins of commercial airliners. With the aim of contributing to a better knowledge of this matter, this paper reports the results of an experimental study upon the indoor air quality aboard commercial aircrafts for 14 domestic flights less than 1 h and half long. The parameters monitored were temperature, relative humidity and carbon dioxide …
First results of iButton® loggers and infrared camera application inside a greenhouse
2017
Greenhouse microclimate management (temperature, relative humidity) plays a very important role in order to optimize the production process improving pest and disease control, irrigation and energy efficiency. The systems mostly used in Sicily (south Italy) to record the ambient parameters are made up of fixed measuring stations able to give useful information about the climate inside the greenhouse limited to some pre-fixed points. In this study we texted a novel system made up of humidity and temperature data loggers (iButton®) placed inside a greenhouse. The iButton® temperature/humidity logger (DS1923) is a rugged, self-sufficient system that measures temperature and/or humidity and r…
Long term energy efficiency study on different wall envelopes in Latvian climate conditions
2017
Abstract Five test stands have been built in Riga, Latvia equipped with sensors (temperature, solar radiation, humidity, etc.) to measure energy efficiency and thermal comfort conditions. Roof and floor constructions are made the same. For the walls building envelopes differ and typical materials used in Latvia (aerated concrete, ceramic building blocks, wooden log and plywood frame with rock wool insulation) are compared. Only rock wool is used for insulation to provide moisture transport through the construction. For study to be comparative thermal transmittance of all five test stands have been calculated equal (U=0.15…0.16 W/(m 2 ∙K)). The aim of research is to compare the integral calc…
Measurement report of the change of PM2.5 composition during the COVID-19 lockdown in urban Xi'an: Enhanced secondary formation and oxidation
2021
Enhanced secondary aerosol formation was observed during the COVID-19 lockdown in Xi'an, especially for polluted episodes. More oxidized‑oxygenated organic aerosol (MO-OOA) and sulfate showed the dominant enhancements, especially in large particle-mode. Meanwhile, relative humidity (RH) showed a positive promotion on the formation of sulfate and MO-OOA during the lockdown, but had no obvious correlation with less oxidized‑oxygenated organic aerosol (LO-OOA) or nitrate. Organosulfurs (OS) displayed a higher contribution (~58%) than inorganic sulfate to total sulfate enhancement in the polluted episode during the lockdown. Although the total nitrate (TN) decreased during the lockdown ascribin…