The effect of Transient over Voltages on the Partial Discharges activity in HVDC joints
2021
Rapid growth of HVDC cable line installations is expected in the coming years. Several research groups have investigated dielectric phenomena that occur in the insulation of HVDC cables and accessories that accelerate aging and reduce the reliability of this technology over time. Unlike in HVAC cables, under HVDC stress, the distribution of the electric field inside the insulation layer depends not only on the applied voltage but also on the temperature distribution and on other factors related to manufacturing such as the presence of impurities. Reaching local and transient electric field peaks can enhance the onset of Partial Discharges (PDs) which can lead to premature aging of the insul…
Predictability of PD inception in defects included in HVDC cables by conductivity models calibrated through experiments
2022
To date, there are several methods for calculating the electric field distribution within a dielectric layer subjected to HVDC voltage. However, experimental techniques for evaluating the accuracy of models for calculating the electric field, such as space charge measurement, are often not precise enough to be used for this purpose. At the same time, the knowledge of Partial Discharge (PD) phenomenon occurring under HVDC stress is also not as developed as that of PD under HVAC voltage. The main goal of this research is to study the effectiveness of dielectric conductivity models to forecast the inception condition for PD under load and HVDC voltage stress. This study has been carried out by…
Partial discharges characteristics during load transients in an HVDC model cable
2021
The occurrence of Partial Discharges (PD) in HVAC cables is widespread considered as one of the most important concerns for the stability of the insulation. To date, the role of PD in the ageing and definitive fault of HVDC cables has been poorly investigated. This is mainly due to some practical difficulties in the performing of the measurements. Compared to the PDs occurring under AC stress, the higher inception voltages and the lower repetition rates, obtainable under DC voltage, make the exclusion of the measurement noise more difficult. This paper is focused on the study of the characteristics of the PDs occurring in an artificial defect located in proximity of the outer dielectric' su…
Characteristics of partial discharges in an experimental setup reproducing HVDC cable insulation operating conditions
2021
The occurrence of Partial Discharge (PD) inside a cavity subjected to HVDC voltage can be considered as one of the most likely sources of insulation ageing and failure. In practical applications, the recognition of PD under HVDC is more difficult than under AC stress because of the lower repetition rates and the impossibility to obtain a PD pattern synchronized with the waveform of the applied voltage. In this paper, the relationship between conduction phenomena in dielectrics and the occurrence of PD is investigated by means of a novel experimental setup. A couple of dielectric cells connected in series is subjected to various HVDC stress levels. The applied voltage is divided between the …
AN ACCURATE MODEL FOR STEADY-STATE AND DYNAMIC ANALYSIS OF THE SICILIAN NETWORK WITH HVDC INTERCONNECTIONS
2021
Sicily is one of the first Italian regions for installed power from renewable energy plants, especially photovoltaic and wind plants, and a crucial point for the Mediterranean energy hub. Its role as nexus between the European and the African Continents is becoming more and more significant due to the realization in a short time of the so called Tyrrhenian link and the High Voltage Direct Current (HVDC) connection with Tunisia. In this framework, the paper presents a model of the Sicily power generation and transmission system, including the Tyrrhenian link and two equivalent buses representing the Sardinian power network and the rest of the Continental Europe (CE) synchronous area, for both …
Modelling of Pulsed Electro Acoustic Method for Space Charge Detection on Single and Multilayer Dielectrics
Reliability of PEA Measurement in Presence of an Air Void Defect
2020
This paper deals with the reliability of the Pulsed Electro-Acoustic (PEA) technique in the case of a specimen containing an air layer. The first approach to this study has been proposed by the authors in previously published works. In these papers, the mathematical description, the PEA cell simulation model, and some experimental tests have been reported. In this work, a more accurate description of the acoustic wave behavior within the PEA cell and specimen with and without an air layer is given. Moreover, the comparison between simulation and experimental tests for both cases (specimen with and without air layer) allowed the validation of the previously developed PEA cell simulation mode…
A new approach to calibrate the thermal conditions in space charge measurements on HVDC mini-cables
2019
The PEA method is currently widespread used for space charge measurements in mini-cables in order to qualify the behavior of semicon-dielectric-semicon compound under electric and thermal stress. The main goal of this research is to quantitatively evaluate the relationship between the thermal boundary conditions applied to cables or mini-cables and the maximum local electric field due to the accumulated space charge. Hitherto, several research groups have obtained thermal gradients over the dielectric's radius heating the conductor by Joule effect due to an induced current. In this paper, a numerical approach is offered to calibrate the heat exchange boundary conditions to apply to a sample…
Pulsed Electro-Acoustic space charge apparatus – qualifying, testing and monitoring of insulation for HVDC cables and accessories
2022
Partial Discharges in HVDC Cables - The Effect of the Temperature Gradient During Load Transients
2021
The paper investigates the role of the space charge accumulation phenomena in the inception of Partial Discharges (PD) in a defect within the bulk of the dielectrics of a High Voltage Direct Current (HVDC) cable. It is widespread accepted that the number of PD occurring in an HVDC cable during its lifetime is largely less than that under AC voltage stress. This is essentially due to higher values of the voltage between the conductor and the screen needed to trigger PD under a steady DC voltage than the same value under AC stress. Nevertheless, due to the dependency of the electrical conductivity of the insulation on the electric field and temperature, PD in HVDC cables is strongly influence…