Electron-transporter spectrometer for on-line isotope separator
1991
Abstract ELLJ — a conversion-electron and beta-ray spectrometer for an on-line isotope separator - is described. The instrument is a broad-range, high-transmission device consisting of a two-coil magnetic transporter plus a cooled Si(Li) detector. The spectrometer was designed to perform several kinds of coincidence measurements. A number of representative spectra of fission-product activities separated on-line at the IGISOL facility demonstrate the performance of the spectrometer.
High-accuracy mass determination of unstable cesium and barium isotopes
1999
Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of $\delta \mbox{m} \approx 13$ keV have been obtained. The masses of $^{123,124,126}$Ba and $^{122m}$Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.
Extension of Penning-trap mass measurements to very short-lived nuclides
2000
Abstract Mass measurements on 33,34,42,43 Ar have been performed at the ISOLTRAP spectrometer. An accuracy of δm ≈4 keV has been achieved for all measured isotopes. With 33 Ar it is the first time that a nuclide with a half-life shorter than one second has been investigated using a Penning trap. This became possible due to the recently installed linear radio-frequency ion-trap system and an improved, faster measurement cycle.
Towards a magnetic field stabilization at ISOLTRAP for high-accuracy mass measurements on exotic nuclides
2008
Abstract The field stability of a mass spectrometer plays a crucial role in the accuracy of mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of fluctuations are temperature variations in the vicinity of the trap and pressure changes in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the temperature and pressure fluctuations by at least an order of magnitude down to Δ T ≈ ± 5 mK and Δ p ≈ ± 5 Pa has been achieved, which corresponds to a relative magn…
Direct mass measurements of neutron-deficient xenon isotopes with the ISOLTRAP mass spectrometer
2000
Abstract The masses of Xe isotopes with 124⩾ A ⩾114 have been measured using the ISOLTRAP spectrometer at the on-line mass separator ISOLDE/CERN. A mass resolving power of 500 000 was chosen resulting in an accuracy of δm ≈12 keV for all isotopes investigated. Conflicts with existing mass data of several standard deviations were found.
Mass measurements on neutron-deficient Sr and neutron-rich Sn isotopes with the ISOLTRAP mass spectrometer
2005
Abstract The atomic masses of 76,77,80,81,86,88 Sr and 124,129,130,131,132 Sn were measured by means of the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. 76 Sr is now the heaviest N = Z nucleus for which the mass is measured to a precision better than 35 keV. For the tin isotopes in the close vicinity of the doubly magic nucleus 132 Sn, mass uncertainties below 20 keV were achieved. An atomic mass evaluation was carried out taking other experimental mass values into account by performing a least-squares adjustment. Some discrepancies between older experimental values and the ones reported here emerged and were resolved. The results of the new adjustment and their impact will be pr…
Cluster isobars for high-precision mass spectrometry
1991
Doublet mass measurements of the isobars28Si3 and12C7 are performed by use of a Penning trap mass spectrometer and the Fourier transform ion cyclotron resonance (FT-ICR). The carbon and silicon cluster ions are produced by laser ablation. Results of these preliminary measurements are presented.
Cluster calibration in mass spectrometry: laser desorption/ionization studies of atomic clusters and an application in precision mass spectrometry.
2003
For accurate mass measurements and identification of atomic and molecular species precise mass calibration is mandatory. Recent studies with laser desorption/ionization and time-of-flight analysis of cluster ion production by use of fullerene and gold targets demonstrate the generation of atomic clusters for calibration purposes. Atomic ion results from the Penning trap mass spectrometer ISOLTRAP, in which a carbon cluster ion source has recently been installed, are presented as an application in the field of precision mass spectrometry.
Laser desorption/ionization cluster studies for calibration in mass spectrometry
2003
Precise mass calibration is mandatory in many fields of mass spectrometry. We have performed laser desorption/ionization cluster studies with a MALDI-TOF mass spectrometer on gold and fullerene targets to produce atomic clusters. These investigations demonstrate that clusters are ideally suited for this purpose. Pulsed N 2 -laser and Nd:YAG-laser ablation was used to produce positively as well as negatively charged clusters. Earlier observations of dianionic metal clusters are confirmed. First results from the tandem Penning trap mass spectrometer ISOLTRAP using carbon clusters as mass references show how carbon clusters can be applied to precision mass spectrometry by providing absolute ma…
Towards high-accuracy mass spectrometry of highly charged short-lived ions at ISOLTRAP
2006
Dedicated to H.-J. Kluge on the occasion of his 65th birthday anniversary - Jürgen Kluge Special Issue; Multiply charged ions of stable xenon isotopes from a plasma ion source have been mass-selected by the on-line mass separator ISOLDE/CERN and delivered to the triple-trap mass spectrometer ISOLTRAP. The doubly charged ions that survived the charge-exchange processes during bunching and ion preparation were transferred to a precision Penning trap for mass determination. Mass values were obtained for the isotopes with mass numbers A=126,129,130,136. They are consistent with previous results except for the case of $^{126}Xe$ where a significant deviation from the literature value was found. …