Search results for "IAC"
showing 10 items of 4189 documents
Minimal Lesions of the Small Intestinal Mucosa: More than Morphology
2020
Minimal lesions of the small bowel are mucosal changes characterized by an increased number of intraepithelial lymphocytes (with or without crypt hyperplasia) and normal villous architecture. Such changes are associated with a wide spectrum of conditions, ranging from food intolerances to infections, and from drugs to immune diseases, with different clinical profiles and manifestations, which complicates the formulation of a differential diagnosis. Patient history, symptom evaluation, and histopathology are the diagnostic features needed to establish a correct diagnosis. Physicians should assist pathologists in formulating a precise morphological evaluation by taking well-oriented small int…
From Clinical Imaging to Patient-Specific Computational Model: Rapid Adaptation of the Living Heart Human Model to a Case of Aortic Stenosis
2021
Aortic stenosis (AS) is the most common acquired heart valve disease in the developed world. Traditional methods of grading AS have relied on the measurement of aortic valve area and transvalvular pressure gradient. Recent research has highlighted the existence of AS variants that do not meet classic criteria for severe AS such as low-flow, low-gradient AS. With the development of sophisticated multi-scale computational models, investigation into the left ventricular (LV) biomechanics of AS offers new insights into the pathophysiology that may guide treatment decisions surrounding AS. Building upon our prior study entailing LV-aortic coupling where AS conditions were applied to the idealize…
Cardiac computed tomography assessment of the near term impact of percutaneous ventricular restoration therapy (parachute®) on mitral valve geometry
2015
Objectives The aim of current study is to assess the near term impact of percutaneous ventricular restoration therapy (PVR), Parachute® on mitral valve (MV) geometry by cardiac computed tomography (CCT). Background Recent data demonstrates the feasibility of PVR for treatment of post anterior myocardial infarction (MI) heart failure. Little is known, however, about the interaction of the device and left ventricular structures, particularly the MV apparatus. Methods This is a retrospective Core Laboratory analysis of Parachute Trials’ CCT data. Patients with paired (before and after Parachute implant) CCT acquisitions were included into analysis. MV geometric parameters were measured. Result…
Patient selection, echocardiographic screening and treatment strategies for interventional tricuspid repair using the edge-to-edge repair technique
2018
Severe tricuspid regurgitation (TR) has long been neglected despite its well-known association with mortality. While surgical mortality rates remain high in isolated tricuspid valve surgery, interventional TR repair is rapidly evolving as an alternative to cardiac surgery in selected patients at high surgical risk. Currently, interventional edge-to-edge repair is the most frequently applied technique for TR repair even though a device has not been developed for this particular indication. Due to the inherent differences in tricuspid and mitral valve anatomy and pathology, percutaneous repair of the tricuspid valve is challenging due to a variety of factors including the complexity and varia…
Update in the Percutaneous Management of Coronary Chronic Total Occlusions
2018
Percutaneous coronary intervention (PCI) for chronic total occlusions (CTOs) has been rapidly evolving during recent years. With improvement in equipment and techniques, high success rates can be achieved at experienced centers, although overall success rates remain low. Prospective, randomized-controlled data regarding optimal use and indications for CTO PCI remain limited. CTO PCI should be performed when the anticipated benefit exceeds the potential risk. New high-quality studies of the clinical outcomes and techniques of CTO PCI are needed, as is the expansion of expert centers and operators that can achieve excellent clinical outcomes in this challenging patient and lesion subgroup. In…
Evaluating the quality of implantation of percutaneous ventricular restoration device (Parachute®) by cardiac computed tomography
2016
Background The Parachute is a novel percutaneously implanted ventricular partitioning device (VPD) that has emerged as a safe and feasible treatment option for patients with heart failure following anterior wall myocardial infarction. VPD efficacy is likely dependent on optimal device placement, but to date there are no published data examining the effect of device positioning on patient outcomes. Methods and results We retrospectively identified 32 patients successfully implanted with the Parachute device, all of whom underwent cardiac computed tomography (CCT) at baseline and after 6 months of follow-up. Patients were divided into two groups based on self-reported improvement in New York …
Utility of Intravascular Ultrasound in Percutaneous Revascularization of Chronic Total Occlusions
2016
Intravascular ultrasound has been used for >20 years to guide percutaneous coronary intervention in different subsets of coronary lesions. During the last decade, the interest in percutaneous coronary intervention for chronic total occlusion (CTO) has increased dramatically, leading to high success rates. Failure of guidewire crossing is the most common reason for failed CTO attempts. Certain angiographic features, such as blunt proximal CTO cap, tortuosity, heavy calcification, and lack of visibility of path in the distal vessel, increase procedural difficulty. A better understanding of the behavior of the guidewire within the CTO segment may represent a key issue to achieve successful …
Updated diagnosticprognostic paradigm for CAD: a narrative review.
2020
Cardiovascular diseases are the first cause of death globally; early detection of coronary artery disease (CAD) is a challenge for clinicians and radiologists. Over the past 2 decades there have been several improvements in the methods for the assessment of diagnosis and prognosis in patients with suspected CAD; most of these methods are imaging methods and they operate with high-end technologies. Cardiac computed tomography (CCT) as we know it today was introduced in 1998 and has ever progressed with constant pace. The first decade was the technical validation phase of the method while the second decade was the clinical validation phase. CCT has developed an excellent diagnostic and progno…
Morphometry of myocardial apex in endurance-trained mice of different ages
1979
Mitochondrial volume density, surface density of the outer mitochondrial membrane, the mean number and size of mitochondria, and the mean surface density of crista membranes together with the volume densities of myofibrils and sarcoplasmic space were morpho-metrically analyzed in cardiac muscle of two groups of sedentary control mice aged 3 and 7 months, and in two groups of mice trained either 1 month rather intensely or 4 months moderately. Of the calculated mitochondrial variables only the surface density of the outer mitochondrial membrane differed between the older controls and the older trained animals, the density being slightly smaller in the trained group. The myofibrillar volume d…
Shot placement within cardiac cycle in junior elite rifle shooters
2007
Abstract Objectives This study examined the timing of the trigger pull in relation to the cardiac cycle during skilled precision shooting. Methods Electrocardiogram was recorded from 20 junior level competitive air-rifle shooters in two separate sessions. The testing was conducted at an indoor shooting range using an optoelectronic shooting system. The experimental task was to fire a shot in the standing position at a distance of 10 m from the target. Results The results showed that the junior level shooters fired more often during the phase of 10–15% of the R wave-to-R wave (R–R) interval. With regards to the accuracy of performance, there was not any optimal location for triggering in the…