Search results for "IGISOL"

showing 10 items of 23 documents

Yield measurements at IGISOL with a digital data acquisition system

2017

A new digital data acquisition system has been installed at the IGISOL facility at the department of Physics in University of Jyväskylä in November, 2016. The technical details of the hardware and software of this new system are presented in this thesis. Nutaq VHS-ADC digital data acquisition system includes an analogue to digital converter (ADC) crate board, an offset unit box, an acquisition host PC, and a storage drive. This system consists of 8 channels, has the capability of 105 MSPS with 14-bit ADCs on 6U cPCI (PXI compatible). Radioactive sources, beta-gamma matrix, gamma-gamma matrix, beta-delayed gamma, and gamma-delayed gamma spectra of radioactive isotopes produced at IGISOL were…

ADCMCPJYFLTRAPA/DBEDACIGISOLIBACFDSPIGtiedonsiirtoTDCtietojärjestelmät
researchProduct

Status of the ion trap project at IGISOL

2001

The IGISOL fa ility at the Department of Physi s of the University of Jyväskylä (JYFL) is delivering radioa tive beams of short-lived exoti nu lei, in parti ular the neutron-ri h isotopes from the ssion rea tion. These nu lei are studied with the nu lear spe tros opy methods. In order to substantially in rease the quality and sensitivity of su h studies the beam should undergo beam handling: ooling, bun hing and isobari puri ation. The rst two pro esses are performed with the use of an RFQ ooler/bun her. The isobari puri ation will be made by a Penning trap pla ed after the RF- ooler element. This ontribution des ribes the urrent status of the ion trap pro je t and its future prospe ts. The…

IGISOL
researchProduct

New off-line ion source infrastructure at IGISOL

2016

Uusi off-line ionilähdeasema on otettu käyttöön IGISOL-laitteistolla Jyväskylän yliopistossa. Tämä opinnäytetyö esittää kyseiseen laitteistoon ja ohjelmistoon liittyvät tekniset yksityiskohdat. Käyttöön otettu järjestelmä sisältää uuden suihkulinjan, uuden glow discharge -tyyppisen ionilähteen sekä ohjausjärjestelmän näille molemmille. Laitteistolla tuotetun hiukkassuihkun massahajotelma paljasti suihkun sisältävän katodimateriaalia odotetusti. Kuitenkin tämän materiaalin määrä oli toivottua pienempi. Työssä esitetään ratkaisuehdotuksia tilanteen parantamiseksi. Suihkulinja todettiin toimivaksi niin suurilta osin kuin tähänastiset testaamismahdollisuudet sallivat todeta. EPICS ohjelmistopak…

IGISOLEPICS
researchProduct

RAPTOR : A new collinear laser ionization spectroscopy and laser-radiofrequency double-resonance experiment at the IGISOL facility

2023

RAPTOR, Resonance ionization spectroscopy And Purification Traps for Optimized spectRoscopy, is a new collinear resonance ionization spectroscopy device constructed at the Ion Guide Isotope Separator On-Line (IGISOL) facility at the University of Jyv\"askyl\"a, Finland. By operating at beam energies of under 10 keV, the footprint of the experiment is reduced compared to more traditional collinear laser spectroscopy beamlines. In addition, RAPTOR is coupled to the JYFLTRAP Penning trap mass spectrometer, opening a window to laser-assisted nuclear-state selective purification, serving not only the mass measurement program, but also supporting post-trap decay spectroscopy experiments. Finally,…

Laser resonance ionizationPhysics - Instrumentation and Detectorscollinear laser spectroscopytutkimuslaitteetFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)nucl-exexotic nucleiNuclear Physics - ExperimentIGISOLlaser resonance ionizationNuclear Experiment (nucl-ex)Detectors and Experimental TechniquesydinfysiikkaNuclear Experimentphysics.ins-detExotic nuclei
researchProduct

Resonance laser ionization developments for IGISOL-4

2012

The work presented in this thesis concentrates on the development of the FURIOS laser ion source towards e cient and selective production of low energy radioactive ion beams. This includes design and development of the ion guide and hot cavity catcher systems for laser ion source use, and the development of in-source and in-jet laser spectroscopy techniques. The work has been carried out at the IGISOL facility in the Accelerator laboratory of the University of Jyväskylä. The FURIOS facility was upgraded and developed during the move to the IGISOL-4 facility. The laser transport was greatly improved in order to allow a large fraction of the initial laser intensity to be transported into the …

Laser resonance ionizationlaseritlaserresonanssi-ionisaatioionitioniohjainionisoiva säteilyspektroskopiaNuclear physicsIGISOLLaser spectroscopylaserspektroskopiaydinfysiikkaIon guide
researchProduct

High-precision measurements of the hyperfine structure of cobalt ions in the deep ultraviolet range

2023

Scientific reports 13(1), 4783 (2023). doi:10.1038/s41598-023-31378-1

MultidisciplinaryPhysics in Generalcollinear laser spectroscopyhyperfine structurespektroskopiadeep ultraviolet600IGISOLkobolttiydinfysiikkaddc:600cobalt[PHYS.PHYS.PHYS-GEN-PH]Physics [physics]/Physics [physics]/General Physics [physics.gen-ph]Scientific Reports
researchProduct

The development and status of the IGISOL technique

1997

Abstract The development of the IGISOL technique since its earliest beginnings at the University of Jyvaskyla in the early '80s is reviewed. The processes involved in ion survival in the ion guide are discussed. The design and performance of ion guides for different types of reactions is summarised. The mass-separated beam quality for different skimmer systems is compared.

Nuclear and High Energy PhysicsChemistryNuclear engineeringRadiochemistryion guideMass separationon-line isotope separationMASS SEPARATIONPRODUCTSIonGARIS IGISOLLISOLISOTOPE SEPARATOR ONLINESkimmer (machine)ION-GUIDELaser beam qualityPROTON-INDUCED FISSIONInstrumentationHELIUMNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Decays of T Z = − 3/2 nuclei 23Al, 31Cl, and 41Ti

2012

This article gives an overview on the decay spectroscopy of T Z  = − 3/2 nuclei 23Al, 31Cl, and 41Ti performed at the Ion Guide Isotope Separator On-Line (IGISOL) facility. The results of the IGISOL experiments are compared to the experimental results that have been published since. The isobaric multiplet mass equation (IMME) has been studied for the T = 3/2 quartets at A = 23 and A = 31. For 41Ti, a detailed comparison to the Gamow–Teller strengths obtained for the analog transitions via charge-exchange reactions has been done. Further improvements in the experimental instrumentation and methods and possible implementations for studying T Z  = − 3/2 nuclei at the new IGISOL facility are di…

Nuclear and High Energy PhysicsIsotopebeta-delayed protonsChemistryCondensed Matter PhysicsBeta decayAtomic and Molecular Physics and OpticsIonMass formulaNuclear physicsIsobaric processbeta decayIGISOLPhysical and Theoretical ChemistryAtomic physicsSpectroscopyMultiplet
researchProduct

Production of refractory elements close to the Z=N line using the ion-guide technique

1998

Production of neutron-deficient isotopes of refractory elements in the A = 80-88 region was studied using the IGISOL technique and the 165 MeV Si-32 + Ni-nat reaction. Radioactive isotopes of Y through Mo could be produced up to the M-T = + 1 line. New information on the decay of the A = 82 and 85 nuclei, including a more detailed decay scheme and more accurate half-life for Y-82, was obtained. (C) 1998 Elsevier Science B.V. All rights reserved.

Nuclear and High Energy PhysicsIsotopes of germaniumAnalytical chemistryONLINE[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesY-81Isotopes of oxygenNuclear physicsIsotopes of protactinium0103 physical sciencesNEUTRON-DEFICIENT ISOTOPES010306 general physicsInstrumentationIsotopes of europiumPhysicsDecay schemeIsotope010308 nuclear & particles physicsRefractory metalsIGISOL TECHNIQUEheavy-ion fusion-evaporation reactionsBeta decayrefractory elementsbeta decayDECAY
researchProduct

Collinear laser spectroscopy of stable palladium isotopes at the IGISOL facility

2020

AbstractCollinear laser spectroscopy on stable palladium isotopes was performed at the IGISOL facility in Jyväskylä in preparation for an experiment on its neutron-rich isotopes. Five transitions from different initial atomic states were tested, with the goal of finding the most spectroscopically efficient. The observed intensities afforded a comparison with atomic-level population predictions based on charge-exchange calculations. For some transitions hyperfine parameters of 105Pd were measured, which were found to be in good agreement with literature values. A King plot analysis was performed using the measured isotope shifts and known charge radii from literature to determine the atomic …

Nuclear and High Energy PhysicsMaterials scienceField (physics)collinear laser spectroscopyPopulationspektroskopiachemistry.chemical_elementPhysics Atomic Molecular & Chemical7. Clean energy01 natural sciences010305 fluids & plasmas0103 physical sciencesSHIFTPhysics::Atomic PhysicsIGISOLPhysical and Theoretical Chemistry010306 general physicsSpectroscopyeducationHyperfine structureeducation.field_of_studyScience & TechnologyIsotopePhysicsCondensed Matter PhysicspalladiumAtomic and Molecular Physics and OpticsPhysics NuclearPhysics Condensed MatterchemistryIsotopes of palladiumPhysical SciencesHYPERFINE-STRUCTUREAtomic physicsydinfysiikkaPalladium
researchProduct