Search results for "IH"
showing 10 items of 9382 documents
CCDC 248544: Experimental Crystal Structure Determination
2004
Related Article: C.Boskovic, A.Sieber, G.Chaboussant, H.U.Gudel, J.Ensling, W.Wernsdorfer, A.Neels, G.Labat, H.Stoeckli-Evans, S.Janssen|2004|Inorg.Chem.|43|5053|doi:10.1021/ic049600f
CCDC 225461: Experimental Crystal Structure Determination
2004
Related Article: M.G.Basallote, F.Estevan, M.Feliz, M.J.Fernandez-Trujillo, D.A.Hoyos, R.Llusar, S.Uriel, C.Vicent|2004|Dalton Trans.||530|doi:10.1039/b315841a
CCDC 711358: Experimental Crystal Structure Determination
2010
Related Article: E.Pardo, D.Cangussu, R.Lescouezec, Y.Journaux, J.Pasan, F.S.Delgado, C.Ruiz-Perez, R.Ruiz-Garcia, J.Cano, M.Julve, F.Lloret|2009|Inorg.Chem.|48|4661|doi:10.1021/ic900055d
Hard cap espresso extraction and liquid chromatography determination of bioactive compounds in vegetables and spices
2017
Abstract A new analytical procedure, based on liquid chromatography with diode array and fluorescence detection, has been proposed for the determination of bioactive compounds in vegetables and spices after hard cap espresso extraction. This novel extraction system has been tested for the determination of capsaicin and dihydrocapsaicin from fresh chilli and sweet pepper, piperine from ground pepper, curcumin from turmeric and curry, and myristicin from nutmeg. Extraction efficiency was evaluated by using acetonitrile:water and ethanol:water mixtures. The proposed method allows the extraction of samples with 100 mL of 60% (v/v) ethanol in water. The obtained limits of quantification for the …
A study of the optical effect of plasma sheath in a negative ion source using IBSIMU code
2020
A plasma sheath inside an ion source has a strong focusing effect on the formation of an ion beam from the plasma. Properties of the beam depend on the shape and location of the plasma sheath inside the source. The most accessible experimental data dependent on the plasma sheath are the beam phase space distribution. Variation of beam emittance is a reflection of the properties of the plasma sheath, with minimum emittance for the optimal shape of the plasma sheath. The location and shape of the plasma sheath are governed by complex physics and can be understood by simulations using plasma models in particle tracking codes like IBSimu. In the current study, a model of the D-Pace’s TRIUMF lic…
A new 18 GHz room temperature electron cyclotron resonance ion source for highly charged ion beams
2020
An innovative 18 GHz HIISI (Heavy Ion Ion Source Injector) room temperature Electron Cyclotron Resonance (ECR) ion source (ECRIS) has been designed and constructed at the Department of Physics, University of Jyväskylä (JYFL), for the nuclear physics program of the JYFL Accelerator Laboratory. The primary objective of HIISI is to increase the intensities of medium charge states (M/Q ≅ 5) by a factor of 10 in comparison with the JYFL 14 GHz ECRIS and to increase the maximum usable xenon charge state from 35+ to 44+ to serve the space electronics irradiation testing program. HIISI is equipped with a refrigerated permanent magnet hexapole and a noncylindrical plasma chamber to achieve very stro…
Nanoporous characterization of modified humidity-sensitive MgO-Al 2 O 3 ceramics by positron annihilation lifetime spectroscopy method
2019
The work was supported by the Ukrainian Ministry of Education and Science. H. Klym thanks Prof. O. Shpotyuk for the fruitful discussion.
Mechanisms of Electron-Induced Single-Event Upsets in Medical and Experimental Linacs
2018
In this paper, we perform an in-depth analysis of the single-event effects observed during testing at medical electron linacs and an experimental high-energy electron linac. For electron irradiations, the medical linacs are most commonly used due to their availability and flexibility. Whereas previous efforts were made to characterize the cross sections at higher energies, where the nuclear interaction cross section is higher, the focus of this paper is on the complete overview of relevant electron energies. Irradiations at an electron linac were made with two different devices, with a large difference in feature size. The irradiations at an experimental linac were performed with varying en…
Accumulation of positrons from a LINAC based source
2020
International audience; The GBAR experiment aims to measure the gravitational acceleration of antihydrogen H̅. It will use H̅+ ions formed by the interaction of antiprotons with a dense positronium cloud, which will require about 1010 positrons to produce one H̅+. We present the first results on the positron accumulation, reaching 3.8±0.4×108 e+ collected in 560 s.
Measurements of the energy distribution of electrons lost from the minimum B-field -- the effect of instabilities and two-frequency heating
2020
Further progress in the development of ECR ion sources (ECRIS) requires deeper understanding of the underlying physics. One of the topics that remains obscure, though being crucial for the performance of the ECRIS, is the electron energy distribution (EED). A well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS was used for the study of EED in unstable mode of plasma confinement, i.e. in the presence of kinetic instabilities. The experimental data were recorded for pulsed and CW discharges with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The measurements were focused on observing differences bet…