Placement of endosseous implants in patients with oral epidermolysis bullosa.
2000
Abstract Objective: To evaluate the feasibility of placing endosseous implants in patients with recessive dystrophic epidermolysis bullosa. This article reports on 4 patients subjected to follow-up. Study Design: Implants were placed in 4 cases. All patients have marked oral involvement, with devastating alterations in the soft and hard tissues in all cases. Results: A total of 15 implants (7 maxillary, 8 mandibular) were placed. All implants integrated successfully and have been restored. The average follow-up from implant placement was 2.5 years (range, 1-4). Conclusions: Our preliminary findings suggest that endosseous implants can be successfully placed and can provide support for prost…
New mesh shape and improved implantation procedure to simplify and standardize open ventral hernia repair: a preliminary report.
2010
Introduction Issues in ventral hernia repair are represented by the need for mesh fixation and how to assure a sufficient mesh overlap of the defect. Aiming to resolve these problems, this study describes a modified technique for ventral and incisional hernia repair based upon a newly developed mesh with a special design. This new type of implant allows broader coverage of the abdominal wall and results in tension- and fixation-free repair. Materials and methods A unique geometrically shaped mesh consisting of a large central body and radiating arms was used to repair ventral or incisional hernia. The mesh was intended not to be point-fixated. The friction of the straps passing through the …
Tentacle-shaped mesh for fixation-free repair of umbilical hernias
2019
Purpose: Mesh fixation and broad overlap represent an open issue in umbilical hernia repair. A proprietary-designed implant with tentacle straps at its boundary has been developed to ensure a suture-free repair and a broader coverage of the abdominal wall. The study describes the results of umbilical hernia procedures carried out with the tentacle-shaped implant and the related surgical technique. Methods: A proprietary tentacle-shaped flat mesh having a central body with integrated radiating arms at its edge was used to repair large umbilical hernias in 62 patients. The implant was placed in preperitoneal sublay. The friction of the straps, crossing the abdominal wall thanks to a special n…
Refractive lens exchange with an array multifocal intraocular lens.
2002
ABSTRACT PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO). RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 ± 3.25 D (-1.75 to -15.50 D), and group B (n=…
Iris-fixated toric phakic intraocular lens: Three-year follow-up
2006
Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…
Coronary embolism in a young patient with nonbacterial thrombotic endocarditis related to antiphospholipid syndrome
2020
myocardial infarction
Are mucous retention cysts and pseudocysts in the maxillary sinus a risk factor for dental implants? A systematic review
2020
Background Mucous retention cysts and pseudocysts of the maxillary sinus are benign lesions present in up to 13% of adult patients. Different surgical approaches for sinus lift and dental implant placement in the presence of these lesions have been proposed. Material and Methods A systematic review was performed following the PRISMA statement recommendations to answer the PICO question: Does the aspiration or removal of mucous retention cysts/pseudocysts before or during sinus lifting and dental implant placing, affect the survival of the implants? The study was pre-registered in PROSPERO (CRD42020185528). Included articles quality was assessed using the “NIH quality assessment tool” and “T…
Inflammatory implant periapical lesion: etiology, diagnosis, and treatment--presentation of 7 cases.
2008
Purpose To investigate implant periapical lesions, and to describe their treatment. The hypothesis of this evaluation is that implant periapical lesions are disorders of the area surrounding the apex of a dental implant, and that their etiology can be multifactorial (ie, vascular impairment, vascular ischemia, overheating of bone during drilling, and implant surface contamination). The diagnosis is based on the clinical manifestations and x-ray findings. The x-ray findings usually involve a periapical radiotransparency. Materials and Methods Seven patients with implant periapical lesions (3 in the upper jaw, and 4 in the mandible) after implant placement are described. All patients reported…
Retinal Imaging through Phakic Iris-Claw IOL.
2014
AbstractBackground: Phakic anterior chamber iris-fixated IOL (PIOL) are established for the correction of high myopia. These patients require attention to macular pathologies. This study was to evaluate the quality of imaging through the PIOLs. Methods: 54 eyes of 31 myopic and hyperopic patients with Verisyse®, Verisyse toric®, and Veriflex® phakic iris-fixated IOL were included. Mean preoperative refraction was −11.0 D and +5.7 D, respectively; mean follow-up time was 7.4 years (5–11 years). A matched control group was formed without PIOL implantation. OCT scans were performed and evaluated qualitatively and quantitatively. Results: In 52 eyes of 31 patients (96%), a 3D-OCT image and fund…
Improvements achieved in an oocyte donation program over a 10-year period: sequential increase in implantation and pregnancy rates and decrease in hi…
2006
Objective To compare outcome parameters and cumulative pregnancy rates (PRs) in oocyte donation cycles over a period of 10 years. Design Retrospective study. Setting University-affiliated assisted reproductive technology program. Patient(s) Women undergoing oocyte donation (10,537 cycles) between 1995 and 2005. Intervention(s) Ovarian stimulation and oocyte retrieval in donors. Embryo transfer performed in recipients after endometrial preparation. Main Outcome Measure(s) Outcome parameters and cumulative PRs were calculated and compared in relation to indication, age, and origin of sperm used. Result(s) Overall PR, implantation rate, clinical PR, and miscarriage rate per embryo transfer per…