Search results for "IMPLANTATION"
showing 10 items of 733 documents
Tricuspid valve repair with the Cardioband system: two-year outcomes of the multicentre, prospective TRI-REPAIR study
2021
AIMS: Tricuspid regurgitation (TR) is associated with high morbidity and mortality rates with limited treatment options. We report one- and two-year outcomes of the Cardioband tricuspid valve reconstruction system in the treatment of ≥moderate functional TR in the TRI-REPAIR study. METHODS AND RESULTS: Thirty patients were enrolled in this single-arm, multicentre, prospective study. Patients were evaluated as having ≥moderate, symptomatic functional TR and deemed inoperable due to unacceptable surgical risk. Clinical, functional, and echocardiographic data were prospectively collected up to two years (mean duration 604±227 days). At baseline, 83% were in NYHA Class III-IV, and the mean LVEF…
Prognostic role of endothelial dysfunction and carotid intima-media thickness in patients undergoing coronary stent implantation
2009
Aim. Impaired endothelial function and increased carotid intima-media thickness are key events in the atherosclerotic process and predict future cardiovascular events in subjects with and without coronary artery disease. The purpose of this study was to investigate whether the vasodilator response to increased flow in the brachial artery and the presence of carotid lesions may have a prognostic significance for in-stent restenosis in patients undergoing coronary angioplasty. Methods. The study population included 58 patients undergoing percutaneous coronary intervention (PCI) with stenting and at least 10 months of follow-up. All patients underwent ultrasound detection of brachial artery re…
External stenting with a new polyester mesh reduces neointimal hyperplasia of vein grafts in a sheep model.
2007
Objective External stents placed around vein grafts have demonstrated effectiveness in reducing neointimal hyperplasia by preventing distension of the thin-walled vein grafts when exposed to arterial pressure. However, the ideal stent material has yet to be defined. The following study investigates the short- and long-term effects of an innovative polyester mesh stent designed with optimized adaptation of circumferential compliance. Methods Following in vitro definition of the ideal macro-porous polyester stent material, a total of 12 sheep underwent implantation of bilateral carotid artery vein graft bypasses. In six sheep, the short-term outcome (four weeks of implantation) was investigat…
Biological responses to individualized small titanium implants for the treatment of focal full-thickness knee cartilage defects in a sheep model.
2019
Abstract Background The present study aimed to evaluate the functional, radiological and histological outcome of a customized focal implant for the treatment of focal full-thickness cartilage defects in sheep. Methods The study used magnetic resonance imaging data as the basis for construction of the titanium implant using a three-dimensional printing technique. This was then placed on the medial condyle of the knee joint in eight sheep and left in place in vivo over a period of six months. Following euthanasia, the local biological response was analyzed using micro-computed tomography, light microscopy and histological evaluation (International Cartilage Repair Society (ICRS) score). The v…
Selection of high potential embryos using time-lapse imaging: the era of morphokinetics.
2013
Incorporation of time-lapse imaging in the field of IVF has provided much information about embryo development. The combination of the embryo appearance (morphology) and the importance of when and how the cellular processes that lead to this appearance occur (kinetics) are now integrated into the unique concept of morphokinetics. At present, efforts are focused on using this information to improve embryo selection and existing success rates without losing sight of the ever-present objective of implementing a single ET strategy to avoid multiple gestations. Several investigative groups have identified predictive morphokinetic variables for embryo viability and implantation potential. Promisi…
The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent…
2012
The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…
Alternative and complementary therapies in osteoarthritis and cartilage repair
2020
Osteoarthritis (OA) is the most common joint condition and, with a burgeoning ageing population, is due to increase in prevalence. Beyond conventional medical and surgical interventions, there are an increasing number of ‘alternative’ therapies. These alternative therapies may have a limited evidence base and, for this reason, are often only afforded brief reference (or completely excluded) from current OA guidelines. Thus, the aim of this review was to synthesize the current evidence regarding autologous chondrocyte implantation (ACI), mesenchymal stem cell (MSC) therapy, platelet-rich plasma (PRP), vitamin D and other alternative therapies. The majority of studies were in knee OA or chond…
Dynamic and static computer-guided surgery using the double-factor technique for completely edentulous patients: A dental technique.
2021
A novel computer-assisted surgery (CAS) technique that merges dynamic and static CAS approaches to treat completely edentulous patients with dental implants is described. Radiographic and surgical stents are designed with specific fiducial markers that are recognized by the static and dynamic CAS software program. During the surgical procedure, implants are placed following the static surgical guide and the indications from the dynamic navigation system. This technique combines the advantages of static and dynamic CAS approaches to allow accurate and predictable minimally invasive implant placement.
Accuracy and the role of experience in dynamic computer guided dental implant surgery: an in-vitro study
2019
Background To compare the accuracy of implant placement using the conventional freehand method and a dynamic navigation system; to assess the role of the surgeon’s experience in implant placement using these two methods. Material and Methods A randomized in-vitrostudy was conducted. Six resin mandible models and 36 implants were used. Two researchers with differing clinical experience (novice and experienced) placed implants using either the Navident dynamic navigation system (navigation group) or the conventional freehand method (freehand group). Accuracy was measured by overlaying the real position in the postoperative CBCT on the virtual presurgical placement of the implant in a CBCT ima…
Ultrastructure of preimplantation genetic diagnosis-derived human blastocysts grown in a coculture system after vitrification
2006
Objective To evaluate ultrastructural features of preimplantation genetic diagnosis (PGD) blastocysts before and after vitrification. Design Descriptive study of both vitrified and fresh hatching blastocysts. Setting PGD program at the Instituto Universitario, Instituto Valenciano de Infertilidad. Patient(s) Patients undergoing PGD donated their abnormal embryos for research (n = 26). Intervention(s) Biopsied embryos were cultured in the presence of human endometrial cells until day 6. Sixteen blastocysts were vitrified. A total of 11 high-scored hatching blastocysts, 6 warmed and 5 fresh, were fixed for ultrastructure. Main Outcome Measure(s) The cytoskeleton structure, type of intercellul…