Search results for "IMPLANTATION"
showing 10 items of 733 documents
A Randomized Trial of a Schlemm's Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma
2014
Purpose To assess the safety and effectiveness of the Hydrus Microstent (Ivantis, Inc, Irvine, CA) with concurrent cataract surgery (CS) for reducing intraocular pressure (IOP) in open-angle glaucoma (OAG). Design Prospective, multicenter, randomized, single-masked, controlled clinical trial. Participants One hundred eyes from 100 patients 21 to 80 years of age with OAG and cataract with IOP of 24 mmHg or less with 4 or fewer hypotensive medications and a washed-out diurnal IOP (DIOP) of 21 to 36 mmHg. Methods On the day of surgery, patients were randomized 1:1 to undergo CS with the microstent or CS alone. Postoperative follow-up was at 1 day, 1 week, and 1, 3, 6, 12, 18, and 24 months. Wa…
European study of the efficacy of a cross-linked gel stent for the treatment of glaucoma
2020
indexation en cours.; PURPOSE: This study investigated the efficacy and safety of a cross-linked collagen stent (XEN 45) with or without cataract surgery in the treatment of glaucoma. SETTING: Real-life setting. DESIGN: Prospective, open-label, multicenter clinical trial. METHODS: Eligible patients with glaucoma inadequately controlled by treatment, or poor compliance or intolerance to topical therapy were included. Patients were divided into those with implant only (solo group; phakic and pseudophakic patients) and implant combined with cataract surgery (combo group). Differences in average intraocular pressure (IOP) and number of medications between baseline and study end (12 months), and…
Posterior‐chamber phakic implantable collamer lenses with a central port: a review
2020
Abstract We aimed to summarize the outcomes reported following the implantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc) for myopia correction. A literature search in PubMed, Web of Science and Scopus was carried out to identify publications reporting clinical outcomes of patients who were implanted with the V4c ICL model and had a follow‐up period of at least 6 months. A total of 35 clinical studies published between 2012 and 2020 were included in the present review. A comprehensive analysis of the available data was performed, focusing on visual and refractive outcomes at different time‐points post‐surgery. In addition, adverse events and other pa…
Long-Term Results After Repair of Type A Acute Aortic Dissection According to False Lumen Patency
2009
Background Late survival and freedom from retreatment on the descending aorta was evaluated after ascending aortic repair for type A acute aortic dissection (TAAAD). Methods Between March 1992 and January 2006, 189 TAAAD patients (mean age, 52 ± 11; range, 17 to 83 years) were included; of these, 58 had a patent false lumen, and 49 had Marfan syndrome. The descending aorta was evaluated postoperatively with computed tomography (CT). Late outcomes were assessed by Cox regression analysis and actuarial survival and freedom from retreatment by the Kaplan-Meier method. Mean follow-up was 88 ± 44 months. Results There were 38 (20%) late deaths. At 10 years, survival was 89.8% ± 2.1% for patients…
Surface characterization and in vivo evaluation of laser sintered and machined implants followed by resorbable-blasting media process: A study in she…
2015
Background This study aimed to compare the histomorphometric and histological bone response to laser-sintered implants followed by resorbable-blasting media (RBM) process relative to standard machined/RBM surface treated implants. Material and Methods Six male sheep (n=6) received 2 Ti-6Al-4V implants (1 per surface) in each side of the mandible for 6 weeks in vivo. The histomorphometric parameters bone-implant contact (BIC) and bone area fraction occupancy (BAFO) were evaluated. Results Optical interferometry revealed higher Sa and Sq values for the laser-sintered/RBM surface in relation to standard/RBM implants. No significant differences in BIC were observed between the two groups (p>0.2…
A novel trephine design for sinus lift lateral approach. Case report
2010
Various techniques are described in the literature, either by crestal or lateral approach. Sinus augmentation has a high percentage of success, but presents a number of intraoperative and postoperative complications. The most frequent complication is the Schneiderian membrane perforation with a percentage of perforations between 11% and 56% according to authors. The aim of this study is to describe another membrane approach technique for the sinus lateral wall osteotomy that minimizes the risk of Schneiderian membrane perforation. We present a case of a 50 year old patient attended the University Dental Clinic (UDC) of International University of Catalonia for implant and crown treatment du…
A Comparison of 2 Mitral Annuloplasty Rings for Severe Ischemic Mitral Regurgitation: Clinical and Echocardiographic Outcomes.
2016
Controversies regarding the choice of annuloplasty rings for treatment of ischemic mitral regurgitation still exist. Aim of the study is to compare early performance of 2 different rings in terms of rest and exercise echocardiographic parameters (transmitral gradient, systolic pulmonary artery pressure, and mitral valve area), clinical outcomes, and recurrence of mitral regurgitation. From January 2008 till December 2013, prospectively collected data of patients who underwent coronary artery bypass grafting and undersizing mitral valve annuloplasty for severe chronic ischemic mitral regurgitation at our Institution were reviewed. A total of 93 patients were identified; among them 44 had sem…
Patient-Specific Rehearsal Feasibility Before Endovascular Repair of Ruptured Abdominal Aortic Aneurysm.
2019
Purpose: To evaluate the feasibility of a patient-specific rehearsal (PsR) before emergency endovascular aneurysm repairs (eEVAR) and its influence on the operation. Materials and Methods: From February 2016 to October 2016, 10 consecutive patients (mean age 75 +/- 7.4 years; 9 men) presenting with a ruptured abdominal aortic aneurysm (rAAA) suitable for standard EVAR were enrolled in the study. A 3-dimensional (3D) model of the abdominal aorta was generated on a virtual reality simulator based on the patient's computed tomography (CT) images. Following the patient-specific simulation setup, PsR was conducted during patient admission or in parallel with the preoperative eEVAR workup. Measur…
Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve
2019
Bicuspid aortic valve (BAV) anatomy has routinely been considered an exclusion in the setting of transcatheter aortic valve implantation (TAVI) because of the large dimension of the aortic annulus having a more calcified, bulky, and irregular shape. The study aims to develop a patient-specific computational framework to virtually simulate TAVI in stenotic BAV patients using the Edwards SAPIEN 3 valve (S3) and its improved version SAPIEN 3 Ultra and quantify stent frame deformity as well as the severity of paravalvular leakage (PVL). Specifically, the aortic root anatomy of n.9 BAV patients who underwent TAVI was reconstructed from pre-operative CT imaging. Crimping and deployment of S3 fram…
Neomyogenesis in 3D Dynamic Responsive Prosthesis for Inguinal Hernia Repair
2018
Despite undisputed improvements, prosthetics hernia repair continues to be affected by unacceptable rates of complications. Postoperative adverse events such as discomfort and chronic pain represent a subject of increasing concern among the surgical community. Poor quality biologic response, stiff scar plates, and mesh shrinkage, a typical effect of conventional static meshes and plugs, are all indicated as the main reasons for many of the complications related to inguinal hernia repair. Even the conventional concept of treatment based upon a supposed reinforcement of the groin consequent to the fibrotic incorporation of meshes, would appear to be inadequate in the light of the latest scien…