Search results for "IMPLANTATION"
showing 10 items of 733 documents
Vertical osteoconductivity and early bone formation of titanium-zirconium and titanium implants in a subperiosteal rabbit animal model.
2013
Objectives The aim of this pilot study was to evaluate the vertical osteoconductive and osteointegrative dynamics around titanium–zirconium (TiZr) implants compared to titanium (Ti) implants. Materials and methods In a split-leg design, 12 TiZr-SLActive and 12 Ti-SLActive implants were inserted 3 mm above bone level in the proximal tibia of 12 rabbits. Full periosteal flaps were repositioned to cover the site. Specimens were obtained after 10, 20 and 30 days (each n = 4 per group). Histomorphometric measurements included percentage of linear bone fill (PLF; %), new marginal vertical bone height (VBH; mm) and vertical bone-to-implant contact (vBIC; %). Statistical analysis was performed with…
The effects of surgical preparation techniques and implant macro-geometry on primary stability : an in vitro study
2016
Background The attainment of a good primary stability is a necessary condition to ensure the success of osseointegration in implantology. In type IV cancellous bone, however, it is possible that a reduced primary stability can lead to an increased rate of failure. The aim of this study was therefore to determine, with the help of the resonance frequency (Osstell mentor), which technique of implant site preparation (piezo surgery, conventional, under-preparation, bone compaction, osteodistraction) and macro-geometry is able to improve implant stability in type IV cancellous bone. Material and Methods 10 pig ribs were prepared with a surgical pre-drilled guide, calibrated for a correct implan…
Amorphous and crystalline polyetheretherketone: Mechanical properties and tissue reactions during a 3-year follow-up.
2007
The study was aimed to test the mechanical strength, structural stability, and tissue reactions of optically amorphous and crystalline polyetheretherketone (PEEK) plates during a 3-year follow-up in vivo and in vitro. The injection-moulded PEEK plates were implanted to the dorsal subcutis of 12 sheep, which were sacrificed at 6-156 weeks. Thereafter, the plates were subjected to tensile tests, and levels of crystallinity were assessed by differential scanning calorimetry (DSC). Histological evaluation was carried out using the paraffin technique. In vitro properties were examined with the tensile test and DSC at 0-156 weeks. Tissue reactions were mild and fairly similar for the amorphous an…
Soft Tissue Healing at One-Piece Zirconia Implants Compared to Titanium and PEEK Implants of Identical Design: A Histomorphometric Study in the Dog
2013
This study aimed to histomorphometrically evaluate the soft tissue reactions of one-piece zirconia implants versus titanium implants in regard to their insertion depth. Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: an uncoated zirconia implant, a zirconia implant coated with a calcium liberating titanium oxide, a titanium implant, and an experimental implant made of a synthetic material. Using a split-mouth design, they were inserted in both submerged and nonsubmerged healing modes. After 4 months, dissected blocks were stained with toluidine blue to histologically assess the marginal portion of the implant mucosa, apical extension of the barr…
Critical temperature modification of low dimensional superconductors by spin doping
2007
Ion implantation of Fe and Mn into Al thin films was used for effective modification of Al superconductive properties. Critical temperature of the transition to superconducting state was found to decrease gradually with implanted Fe concentration. it was found that suppression by Mn implantation much stronger compared to Fe. At low concentrations of implanted ions, suppression of the critical temperature can be described with reasonable accuracy by existing models, while at concentrations above 0.1 at.% a pronounced discrepancy between the models and experiments is observed.
Osteogenic parameters surrounding trabecular tantalum metal implants in osteotomies prepared via osseodensification drilling
2019
Background Surgical fixation of implants into bone for the correction of bone deformities or defects is a traditional approach for skeletal stabilization. Important measures of efficacy of implants include implant stability and osseointegration—the direct interaction between living bone and an implant. Osseointegration depends on successful implant placement and subsequent bone remodeling. This study utilized osseodensification drilling (OD) in a low bone density model using trabecular metal (TM) implants. Material and Methods Three osteotomy sites, Regular, OD-CW (clockwise), and OD-CCW (counterclockwise), were prepared in each ilium of three female sheep. Drilling was performed at 1100rpm…
Histological and histomorphometric study using an ultrasonic crestal sinus grafting procedure: a multicenter case study
2016
Background: The aim of this study was to evaluate the efficacy of a hydrodynamic ultrasonic driven transcrestal sinus grafting procedure (Intralift ®, Acteon Company, Bordeaux, France) and the use of a bovine high temperature sintered grafting material in sinus sites with less than 5 mm remaining bone height with no additional autogenous bone in order to create a sufficient recipient site for implants. Material and Methods: 12 patients (16 sinus) in this multicenter case study were included. Using a crestal approach, bone under the sinus was prepared with ultrasonic tips until the Schneiderian membrane was reached. With a trumpet shaped instrument, the Schneiderian membrane was elevated. In…
Accidental displacement and migration of endosseous implants into adjacent craniofacial structures: A review and update
2011
Objectives: Accidental displacement of endosseous implants into the maxillary sinus is an unusual but potential complication in implantology procedures due to the special features of the posterior aspect of the maxillary bone; there is also a possibility of migration throughout the upper paranasal sinuses and adjacent structures. The aim of this paper is to review the published literature about accidental displacement and migration of dental implants into the maxillary sinus and other adjacent structures. Study Design: A review has been done based on a search in the main on-line medical databases looking for papers about migration of dental implants published in major oral surgery, periodon…
Anterior Capsule Opening Contraction and Late Intraocular Lens Dislocation after Cataract Surgery in Patients with Weak or Partially Absent Zonular S…
2021
Background and Objectives: To evaluate anterior capsule opening (ACO) contraction and late intraocular lens (IOL) dislocation after cataract surgery in patients with weak or partially absent zonular support and assess methods of reducing these complications. Materials and Methods: For this prospective study, we enlisted cataract surgery patients in our hospital with preoperative diagnoses of weak zonules. All patients received phacoemulsification surgery with implantation of a hydrophobic acrylic IOL and capsular tension ring (CTR). ACO reductions were measured for six months after enrolment. Data on late IOL dislocations were collected five years after enrolment of the last patient. Result…
Determinants of endometrial receptivity.
2005
Understanding the molecular changes that occur during the window of implantation is fundamental to our knowledge of human reproduction. Lately, the development of microarray technology has allowed this process to be studied from a global molecular perspective. In the last 2 years, researchers have focused their efforts on throwing light on the gene expression profile of the receptive endometrium. The genes hold the key to the development of the endometrium at any stage, and we have focused our work on the window of implantation. The four most recently published works in this field have revealed a long list of genes that are up- or downregulated at the time of implantation. Although these st…