Search results for "IMPLANTATION"
showing 10 items of 733 documents
Prosthetic strap system for simplified ventral hernia repair. Its results in a porcine experimental model.
2010
Abstract: Introduction Aiming to achieve a simplified ventral hernia repair, a proprietary shaped mesh was experimentally tested in the porcine model. The mesh is structured with a large central body and radiating straps. The friction of the straps passing through the tissues are hypothesized to be adequate to maintain the mesh in place during tissue ingrowth, avoiding classic point fixation while ensuring a wide coverage of the abdomen. Methods The mesh, having 6 radial straps, was placed using a sublay preperitoneal technique in 4 pigs. All straps were passed laterally through the abdominal wall and exteriorized from the skin. The straps were trimmed at the level of the skin, allowing the…
Hemosuccus pancreaticus--a rare cause of gastrointestinal bleeding: diagnosis and interventional radiological therapy.
2000
Hemorrhage from the pancreatic duct, i.e. hemosuccus pancreaticus (HP), is a rare cause of gastrointestinal bleeding. Pancreatic hemosuccus is usually due to the rupture of an aneurysm of a visceral artery, most likely the splenic artery, in chronic pancreatitis. Other causes of HP are rare. We present a case of HP in a female patient with no history but with positive findings of chronic calcifying pancreatitis upon ultrasonographic investigation, computed tomography scan, and endoscopic retrograde cholangiopancreatography. With detectable fresh blood in the descending duodenum, angiography of the celiac artery revealed an aneurysm of the splenic artery as the suspected cause of intermitten…
Acute inflammatory response after inguinal and incisional hernia repair with implantation of polypropylene mesh of different size.
2005
The purpose of this study was to assess the modifications of interleukin (IL)-6, C-reactive protein (CRP), leukocytes and fibrinogen after implantation of polypropylene mesh.Thirty-six patients were included in this study and divided into two groups. To the first group were allocated patients affected by inguinal hernia and undergoing conventional repair (subgroup Ia) or hernioplasty with 40-cm(2) polypropylene mesh (subgroup Ib). To the second group were allocated patients affected by incisional hernia and undergoing conventional repair (subgroup IIa) or incisional hernia repair with 400-cm(2) polypropylene mesh (subgroup IIb). Peripheral venous blood samples were collected 24 h before sur…
Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ®
2012
Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method. Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor ® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive m…
Histopathologic Findings in Early Encapsulated Blebs of Young Patients Treated With the Ahmed Glaucoma Valve
2010
Objective/aim Uncontrolled glaucoma presents a challenge for the ophthalmic surgeon especially in children and juvenile patients. For many patients who have undergone failed surgical procedures before, episcleral implants remain the last choice. Encapsulated blebs forming over antiglaucoma devices present a complication leading to malfunctioning or even failure with reincrease in intraocular pressure. We report our histopathologic findings of such blebs developing around the Ahmed glaucoma valve (AGV) after a short time period in young patients. Materials and methods Nine young patients (2 to 17 y of age) with otherwise uncontrollable glaucoma were treated with AGV (models FP-7 and FP-8, si…
Implantation of a custom intraocular lens with a 30-diopter torus for the correction of high astigmatism after penetrating keratoplasty.
2003
Abstract We present a 62-year-old woman who had implantation of an intraocular lens (IOL) with a torus of 30.0 diopters (D) in an eye after penetrating keratoplasty. The patient presented with cataract and a best corrected visual acuity of 20/400. Penetrating keratoplasty was performed in 1975 because of decompensated keratoconus. With a clear but inferiorly decentered corneal graft, visual acuity was limited because of keratoplasty-related high corneal astigmatism of 22.5@156 that could not be successfully treated with spectacles or contact lenses. A custom toric IOL with –30.0 D of cylindrical power was implanted in the capsular bag via a sclerocorneal tunnel incision. Additionally, a sph…
Tapering of the Megaureter
2012
Neo-nervegenesis in 3D dynamic responsive implant for inguinal hernia repair. Qualitative study.
2020
Abstract Background Prosthetic repair of inguinal hernias is one of the most performed surgical procedures. Nevertheless, high rates of complications affect the surgical treatment. Implant fixation, poor-quality tissue ingrowth and mesh shrinkage seem to be involved in postoperative complications, discomfort and chronic pain following inguinal hernia repair. To address these issues a multilamellar shaped 3D dynamic responsive prosthesis has been developed. This new implant, positioned fixation-free to obliterate the hernia opening, thanks its inherent dynamic compliance during inguinal movements, has demonstrated to induce an enhanced biological response. The ingrowth of newly formed muscle…
Optical analysis to predict outcomes after implantation of a double intraocular lens magnification device.
2007
Purpose To analyze the effect of different optical parameters of the eye on the outcomes of implantation of a double intraocular lens (IOL) magnification device in patients with low vision. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The eye's refraction and magnification before and after surgery were evaluated using a theoretical eye model based on paraxial optics approximation. Four parameters on which refraction and magnification are dependent were evaluated: anterior chamber depth (ACD), axial length (AL), mean keratometry (Km), and the distance between the 2 implanted IOLs. The 4 variables were analyzed separately in the first stage. Next, different combi…
Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts
2020
Abstract Introduction Spontaneous acute aortic syndrome (IAAS) is rarely localized in the infrarenal aorta. The endovascular approach is preferred over conventional open surgery with fewer complications. However, dedicated endovascular devices for IAAS treatment are unavailable. The aim was to report a large single-center experience using unibody stent-grafts to address IAAS. Methods From April 2016 to March 2019, a retrospective analysis of patients presenting spontaneous and isolated IAAS was performed. Patients addressed with the unibody stent-graft (AFX endovascular AAA system; Endologix Inc., Irvine, CA) were included in the study. Indications to IAAS treatment were persistent symptoms…