Search results for "IMPLANTATION"
showing 10 items of 733 documents
Clinical retrospective study of dental implant removal : do patients who require implant removal desire implant prosthesis again?
2020
Background This study investigated the causes of dental implant removal due to complications, and examined whether patients who had dental implant removal desired re-implant prosthesis treatments. Material and Methods A retrospective case–control study was conducted on patients who had their dental implants removed. We investigated whether the removed dental implant was replaced with other implant prostheses. Age, sex, diabetes, smoking, implant site distribution, reason for implant removal, and blade and root-form implants were categorized as predictive variables. The outcome variable was desire for re-implantation or use of other prosthetic methods after implant removal. A logistic regres…
Segmental sandwich osteotomy of the posterior mandible in pre-implant surgery - A systematic review
2017
Background The rehabilitation of the atrophic posterior mandible with dental implants often requires bone augmentation procedures. The aim of the present study is the systematic review of the literature concerning the success rate of Segmental Sandwich Osteotomy (SSO) of the posterior mandible in pre-implant surgery. Material and Methods Systematic review of all clinical cases and clinical studies of SSO of the posterior mandible in pre-implant surgery with a minimum follow-up of 6 months after implant loading was performed, based on specific inclusion and exclusion criteria. The search strategy involved searching the electronic databases of MEDLINE, EMBASE, COCHRANE LIBRARY, Clinical Trial…
Predictability of short implants ( < 10 mm) as a treatment option for the rehabilitation of atrophic maxillae: a systematic review
2016
Background Short implants (< 10 mm) are one of the treatment options available in cases of limited vertical bone. A purpose of this paper is to evaluate the predictability of short implants as an alternative to technically molthough such implants are now widely used, there is controversy regarding their clinical reliability. There complex treatments in patients with atrophic maxillae, based on a systematic review of the literature and the analysis of the implant survival rates, changes in peri-implant bone level, and associated complications. It is postulated that short implants offer clinical results similar to those of longer implants. Material and Methods A Medline-PubMed search was made…
Quality assessment of systematic reviews regarding the effectiveness of zygomatic implants: an overview of systematic reviews
2020
Background Oral rehabilitation of atrophic maxillae features high complexity, for which there are several therapeutic modalities reported on scientific literature. Zygomatic implant placement is a viable option that features low morbidity and allows immediate prosthetic loading. The purpose of the present study was to determine the methodological quality of systematic reviews that assessed the effectiveness of zygomatic implants placed in atrophic maxillae. Material and Methods Searches were conducted on Medline via Pubmed, LILACS, Dare Cochrane, Scopus, and Sigle via Open Grey up to June 2019. Results Seven systematic reviews were eligible for Overview and comprised a total of 2313 patient…
Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes
2018
The following article: Jung, R.E., Al-Nawas, B., Araujo, M., Avila-Ortiz, G., Barter, S., Brodala, N., ... Windisch, P. (2018). Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes. Clinical Oral Implants Research, 29(S16), 69-77, can be accessed at https://doi.org/10.1111/clr.13342. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. Objectives: The aim of Working Group 1 was to address the influence of different local (implant length, diameter, and design) and systemic (medications) factors on clinical, radiographic, and patient‐re…
Acute heart failure due to giant left atrium: remote ECLS implantation for interhospital transfer and bridging to decision
2018
AbstractBackgroundRemote extracorporeal life support (ECLS) implantation and mobile ECLS are increasingly applied to enable the treatment of patients with refractory heart failure at specialized care centers. Giant left atrium (GLA) is a rare cause but may lead to acute and devastating heart failure.Case reportAcute heart failure that gave rise to a prolonged period of out-of-hospital cardiopulmonary resuscitation in a patient who underwent remote ECLS implantation was found to have resulted from a GLA of impressive dimensions. There having no reasonable option for immediate surgical therapy, the patient was successfully bridged to recovery with a view to subsequent heart transplantation.Co…
Funktionsangiographie der kniegelenknahen Arterien: Konsequenzen für die Stentimplantation?
1990
Angiographic studies of the arteries adjoining the knee in 25 patients show extensive kinking and stenoses of the popliteal artery and less frequently of the distal femoral artery during flexion of the knee joint. This is due to the loss of elasticity with increasing age forcing the vessel into a tortuous course during shortening of the pathway of the popliteal artery with knee flexion. Independent of the principle of the different stents available they probably will not increase the contractility of the stented vessel in the longitudinal axis. It is to expect that after implantation of stents into the popliteal artery kinking will occur predominantly in the original segments of the vessel …
Precise Determination of the Unperturbed 8B Neutrino Spectrum
2012
The measurement was performed at the Kernfysisch Versneller Instituut (KVI) at the University of Groningen, The Netherlands.; A measurement of the final state distribution of the 8B $\beta$ decay, obtained by implanting a 8B beam in a double-sided silicon strip detector, is reported here. The present spectrum is consistent with a recent independent precise measurement performed by our collaboration at the IGISOL facility, Jyvâskylä [O. S. Kirsebom et al., Phys. Rev. C 83, 065802 (2011)]. It shows discrepancies with previously measured spectra, leading to differences in the derived neutrino spectrum. Thanks to a low detection threshold, the neutrino spectrum is for the first time directly ex…
Appropriateness of surgery performed for abdominal aortic aneurysm at tertiary hospitals in Spain
2021
Background: The aim of this study was to analyze the appropriateness of the type of repair (open or endovascular) performed for abdominal aortic aneurysm (AAA) in five university hospitals in Spain, according to evidence-based recommendations. Methods: A multicenter, retrospective cross-sectional study of patients with AAA who underwent elective open surgical repair (OSR) or endovascular aneurysm repair (EVAR). Data were collected on demographic and clinical variables and type of surgical repair. A pair of vascular surgeons from each participating hospital performed a blinded assessment based on GRADE recommendations. The concordance between the two evaluators and the agreement between thei…
Effects of Excimer Laser Irradiation on the Morphological, Structural, and Electrical Properties of Aluminum-Implanted Silicon Carbide (4H-SiC)
2022
This paper reports on the effects of excimer laser irradiation on an aluminum (Al)-doped silicon carbide (4H-SiC) layer. Specifically, high-concentration (1 × 1020at/cm3) Al-implanted 4H-SiC samples were exposed to a few pulses of 308 nm laser radiation (pulse duration of 160 ns), with fluence varying from 1.0 to 2.8 J/cm2. As a starting point, the laser-induced modifications of the morphological, microstructural, and nanoelectrical properties of the exposed 4H-SiC surface were monitored by combining different techniques. From these investigations, an evolution of the surface morphology was observed that can be ascribed to a conversion during irradiation of the uppermost part of the 4H-SiC …