Search results for "IMPLANTATION"

showing 10 items of 733 documents

Intraocular pressure after small incision cataract surgery: temporal sclerocorneal versus clear corneal incision.

2001

To compare intraocular pressure (IOP) after phacoemulsification and foldable intraocular lens (IOL) implantation using a temporal sclerocorneal or clear corneal incision.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.One hundred patients (100 eyes) with cataract having phacoemulsification with posterior chamber IOL implantation were randomly assigned to receive a temporal sclerocorneal or clear corneal tunnel incision. Intraocular pressure was measured preoperatively and 6 hours, 1, 2, and 3 days, and 5 months postoperatively. Statistical significance was determined by nonparametric group comparisons using 2-sample random Wilcoxon tests.Six hours postoperatively,…

AdultMaleIntraocular pressuremedicine.medical_specialtygenetic structuresmedicine.medical_treatmentIntraocular lensCataractCorneaLens Implantation IntraocularCorneaOphthalmologymedicineHumansMinimally Invasive Surgical ProceduresProspective StudiesSclerocorneaIntraocular PressureAgedAged 80 and overPhacoemulsificationbusiness.industryPhacoemulsificationCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryScleraOphthalmologymedicine.anatomical_structureSurgeryFemalesense organsbusinessSurgical incisionScleraJournal of cataract and refractive surgery
researchProduct

Comparison of peri-implant bone loss between conventional drilling with irrigation versus low-speed drilling without irrigation

2016

Background To compare the technique of high speed drilling with irrigation and low speed drilling without irrigation in order to evaluate the success rate and peri-implant bone loss at 12 months of follow-up. Material and Methods A randomized, controlled, parallel-group clinical trial was carried out in patients requiring dental implants to rehabilitate their unitary edentulism. Patients were recruited from the Oral Surgery Unit of the University of Valencia (Spain) between September 2014 and August 2015. Patients who met the inclusion criteria were randomized to two groups: group A (high-speed drilling with irrigation) and group B (low-speed drilling without irrigation). The success rate a…

AdultMaleIrrigationTime FactorsAlveolar Bone LossDentistryTherapeutic irrigation02 engineering and technologylaw.invention03 medical and health sciencesPostoperative Complications0302 clinical medicineRandomized controlled triallawHumansMedicineTherapeutic IrrigationGeneral DentistryAgedAged 80 and overEdentulismbusiness.industryResearchDental Implantation EndosseousDrilling030206 dentistryMiddle Aged021001 nanoscience & nanotechnologymedicine.disease:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologyLow speedMaxillaUNESCO::CIENCIAS MÉDICASFemaleSurgeryImplantOral Surgery0210 nano-technologybusinessFollow-Up Studies
researchProduct

Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes

2019

Objective To analyze the changes in corneal biomechanical parameters of keratoconic eyes with and without intracorneal ring segment (ICRS) implants after 1 year of corneoscleral contact lens (CScL) wear. Methods Seventy-four eyes of 74 patients were divided into three groups: healthy subjects (29 eyes, control group), and 2 groups of subjects with keratoconic eyes (one group of 20 eyes with ICRS implants and one of 25 eyes without them), which were fitted with CScL. Corneal hysteresis (CH), corneal resistance factor (CRF), and corneal-compensated intraocular pressure (IOPcc) were evaluated before fitting CScL and after 1 year of CScL wear. In addition, endothelial cell count (ECC) and centr…

AdultMaleKeratoconusIntraocular pressuremedicine.medical_specialtygenetic structuresContact LensesCorneal StromaKeratoconusEndothelial cell countCorneaProsthesis ImplantationCorneoscleral contact lensCorneal hysteresisTonometry OcularYoung Adult03 medical and health sciences0302 clinical medicineProsthesis FittingCorneaOphthalmologyHumansMedicineProspective StudiesIntracorneal ring segmentIntraocular Pressurebusiness.industryHealthy subjectsProstheses and Implantsmedicine.diseaseElasticityeye diseasesBiomechanical PhenomenaOphthalmologyCross-Sectional Studiesmedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsbusiness030217 neurology & neurosurgeryEye & Contact Lens: Science & Clinical Practice
researchProduct

Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis.

2012

To evaluate the efficacy, predictability, and safety of implantation of Ferrara-type intrastromal corneal ring segments (ICRS) for refractive correction of paracentral keratoconus.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Snellen uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation for keratoconus. The tunnels for ICRS implantation were created with a femtosecond laser. The power vector and the Alpins method were used to analyze postoperative refractive outcomes.The study evaluated 56 eyes of 49 patients. The mean UDVA was 0.17 ± 0.14 (SD) preoperatively and 0.41 …

AdultMaleKeratoconusmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentCorneal StromaVision DisordersVisual AcuityComa (optics)Power vectorKeratoconusRefraction OcularCohort StudiesProsthesis ImplantationYoung AdultOphthalmologymedicineHumansPolymethyl MethacrylateProspective StudiesAlpins methodAgedIntrastromal corneal ring segmentbusiness.industryCorneal TopographyProstheses and ImplantsMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryOphthalmologySurgeryFemalesense organsLaser TherapyCorneal ringbusinessJournal of cataract and refractive surgery
researchProduct

Reconstruction of large mandibular and surrounding soft-tissue defects using distraction with bone transport.

2012

Reconstruction of large bone and soft-tissue defects of the inferior third of the face is possible using various surgical techniques. Patients who require these procedures need to be in good general health, may have sequelae linked to donor sites, and require several interventions to achieve good aesthetic and functional results. The aim of this study was to report outcomes in patients with large mandibular and soft-tissue defects treated using osteogenic distraction with bone transport. Between 2001 and 2008, 14 patients had distraction with bone transport. Most patients were men (92.1%). The mean age was 43.1 years. The average mandibular bone reconstruction was 13.6 cm. The mean duration…

AdultMaleMandibular ProsthesisOsteogenesis DistractionDentistryMandibleYoung AdultDistractionBone plateMedicineHumansBone transportFacial InjuriesAgedBone Transplantationbusiness.industryDental prosthesisDental Implantation EndosseousMandibleSoft tissueMandibular ProsthesisMiddle AgedPlastic Surgery ProceduresMandibular InjuriesOtorhinolaryngologySurgeryFemaleWounds GunshotGeneral healthDental Prosthesis Implant-SupportedOral SurgerybusinessBone PlatesInternational journal of oral and maxillofacial surgery
researchProduct

Biaxial Microincision versus Coaxial Small-Incision Clear Cornea Cataract Surgery

2005

Objective To compare clinical outcomes of biaxial microincision (1.5 mm) and coaxial small-incision (2.75 mm) clear cornea cataract surgery. Design Randomized controlled clinical trial. Participants Seventy eyes of 70 patients were examined at a German university eye hospital. Intervention The 70 patients (70 eyes) were assigned randomly (1:1) to a biaxial or conventional coaxial incision group. Both groups underwent phacoemulsification using pulsed ultrasound energy with variable duty cycles, followed by microincision intraocular lens implantation. Main Outcome Measures Best-corrected visual acuity (BCVA), astigmatism, laser flare photometry value, effective phacoemulsification time (EPT),…

AdultMaleMicrosurgerymedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityCell CountIntraocular lensAstigmatismCorneaLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedAged 80 and overPhacoemulsificationbusiness.industryEndothelium CornealAstigmatismPhacoemulsificationMiddle AgedCataract surgerymedicine.diseaseOphthalmologyFemalemedicine.symptomCoaxialbusinessSurgical incisionOphthalmology
researchProduct

Incidence of posterior vitreous detachment after cataract surgery

2009

Purpose To report the incidence of posterior vitreous detachment (PVD) after uneventful state-of-the-art small-incision phacoemulsification with implantation of a posterior chamber intraocular lens (PC IOL). Setting Department of Ophthalmology, Ludwigshafen Hospital, Ludwigshafen, Germany. Methods This prospective study evaluated the vitreous status of eyes by biomicroscopic examination, indirect binocular ophthalmoscopy, and B-scan ultrasonography before planned cataract surgery. Patients with the posterior vitreous attached were included for follow-up and examined 1 week, 1 month, and 1 year after uneventful phacoemulsification with PC IOL implantation. The preoperative prevalence and pos…

AdultMaleMicrosurgerymedicine.medical_specialtygenetic structuresEye diseasemedicine.medical_treatmentVitreous DetachmentPosterior vitreous detachmentOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularGermanyOphthalmologymedicineHumansProspective StudiesDioptreAgedUltrasonographyAged 80 and overPhacoemulsificationmedicine.diagnostic_testbusiness.industryIncidencePhacoemulsificationMiddle AgedMicrosurgeryCataract surgerymedicine.diseaseeye diseasesSensory SystemsSurgeryVitreous DetachmentOphthalmologyFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Immediate Implant Placement in Fresh Mandibular Molar Extraction Socket: 8-Year Results. A Case Report

2010

Abstract Recently, successful implant placement in fresh extraction sockets has been reported. In this case report, we present the results of an immediate implant placement in a fresh extraction socket of a mandibular molar with simultaneous bone regeneration using a nonresorbable membrane and no other graft materials. Clinical and radiographic findings acquired 8 years after implant placement demonstrated a stable peri-implant situation and confirmed a satisfactory treatment result.

AdultMaleMolarAlveolar Bone LossDentistryMandibleTreatment resultsTooth FracturesDental Implants Single-ToothHumansMedicineTooth SocketBone regenerationPolytetrafluoroethyleneOrthodonticsSocket preservationCrownsbusiness.industryDental Implantation EndosseousDental prosthesisExtraction (chemistry)Membranes ArtificialImmediate implantMolarTooth ExtractionGuided Tissue Regeneration PeriodontalDental Prosthesis Implant-SupportedOral SurgerybusinessMandibular molarFollow-Up StudiesJournal of Oral Implantology
researchProduct

Maintenance of Class III Trifurcated Molars Versus Implant Placement in Regenerated Extraction Sockets: Long-Term Results of 2 Cases

2011

Studies to date have reached differing conclusions regarding the long-term prognosis of teeth with class III furcation involvement. Replacement of such teeth with implants could be an alternative. This report compares the treatment outcomes of 2 cases with similar disease progression: 1 treated by implant therapy and 1 maintained with nonsurgical periodontal treatment. Two patients with advanced chronic periodontitis and class III furcation involvement of all molars were treated. Case 1 received a conservative periodontal and antibiotic treatment, followed by 15 years of maintenance. In case 2, the molars were extracted and replaced with implants, and the implants were observed for 7 years.…

AdultMaleMolarDentistryMandibleClass iiiFurcation InvolvementTooth LossMaxillaHumansMedicineTooth SocketDental ImplantsOrthodonticsSocket preservationbusiness.industryFurcation DefectsDental Implantation EndosseousDental Plaque IndexMandibleAlveolar Ridge AugmentationLong term resultsMolarSurvival AnalysisImplant placementTreatment OutcomeMaxillaChronic PeriodontitisTooth ExtractionGuided Tissue Regeneration PeriodontalDental ScalingFemaleOral SurgerybusinessFollow-Up StudiesJournal of Oral Implantology
researchProduct

Mandibular Molar Root Resection Versus Implant Therapy: A Retrospective Nonrandomized Study

2009

AbstractSuccess rates for both periodontal and implant therapy are often dependent on site and tooth type. For periodontally involved mandibular molars, the decision to hemisect or to extract and place an implant is often complicated. The purpose of the present study was to evaluate the outcomes of the aforementioned treatment modalities for mandibular molars in a private practice setting. A retrospective chart review was performed. In one group of patients (n = 32), 56 mandibular first or first and second molars were treated by hemisection (Group H). A second group (n = 28) received 36 implants in the mandible to replace periodontally involved first or first and second molars (Group I). Al…

AdultMaleMolarmedicine.medical_treatmentDentistryMandibleStatistics NonparametricDental Implants Single-ToothPostoperative Complicationsstomatognathic systemPeriodontal Attachment LossHumansMedicineDental Restoration FailureLongitudinal StudiesTooth RootDental Restoration PermanentDental implantAgedRetrospective StudiesTooth NonvitalOrthodonticsbusiness.industryFurcation DefectsDental Implantation EndosseousMandibleFurcation defectRetrospective cohort studyMiddle AgedMolarClinical trialTreatment OutcomeTooth ExtractionFemaleImplantOral SurgerybusinessDental restorationJournal of Oral Implantology
researchProduct