Innovative barriers for peritoneal adhesion prevention: liquid or solid? A rat uterine horn model.
2005
Objective To compare the effects of solid barriers (PDLA membrane and foil, Interceed), innovative barrier solutions (Adept and Hyalobarrier Gel, phospholipid emulsion), and Ringer’s lactate solution in preventing postsurgical peritoneal adhesions in the rat. Design Prospective, randomized experimental study. Setting Rat model in an academic research environment. Animal(s) Female, nonpregnant Wistar rats. Intervention(s) Standardized surgical injuries were applied to the parietal and visceral peritoneum and the uterine horns. The barrier agents were applied and the wound was closed. A second-look laparoscopy was performed 31 days after surgery to assess adhesion formation. Main Outcome Meas…
Meta-analytic study of implant survival following sinus augmentation
2011
Objectives: To evaluate graft types used for maxillary sinus augmentation and review success rates of dental implants inserted in these areas, analyzing the graft materials used, implant surface types and the moment of implant placement. Study Design: A meta-analytic study reviewing articles on sinus augmentation published during the last ten years. Results: 3,975 implants placed in sinus augmentations (with bony windows) were registered, of which 3,749 implants survived, a survival rate of 94.3%. Conclusions: When performing sinus augmentation, bone substitute materials are just as effective as autologous bone, whether used alone or in combination with autologous bone. Implant surface trea…
Translational development and pre-clinical evaluation of prototype gastrointestinal mock-up devices: only robotic placement of plastic?
2020
Background: The aim of this study was to address the vision of wireless theranostic devices distributed along the gastrointestinal (GI) tract by defining design requirements, developing prototype mock-ups, and establishing a minimally invasive surgical approach for the implantation process. Methods: Questionnaires for contextual analysis and use case scenarios addressing the technical issues of an implantable GI device, a possible scenario for implantation, preparation and calibration of a device, and therapeutic usage by professionals and patients were completed and discussed by an interdisciplinary team of surgeons, engineers, and product designers. Two acute porcine experiments were cond…
Indications and contraindications of dental implants in medically compromised patients: update.
2013
The aim of this study was to review the current scientific literature in order to analyse the indications and contraindications of dental implants in medically compromised patients. A reference research was carried out on PubMed using the key words “implant” AND (oral OR dental) AND (systemic disease OR medically compromised), in articles published between 1993 and 2013. The inclusion criteria were the following: clinical studies in which, at least, 10 patients were treated, consensus articles, reviewed articles and meta-analysis performed in humans treated with dental implants, and which included the disease diagnosis. A total of 64 articles were found, from which 16 met the inclusion crit…
Three-Year Results of Hydrus Microstent with Phacoemulsification
2019
Abstract We report the 3-year IOP efficacy of the implantation of the Schlemm’s canal Hydrus® Microstent (Ivantis®) combined with phacoemulsification versus phacoemulsification alone
Bacterial inactivation/sterilization by argon plasma treatment on contaminated titanium implant surfaces: in vitro study
2015
Background: Surface treatment by argon plasma is widely used as the last step of the manufacturing process of ti- tanium implant fixtures before their sterilization by gamma rays. The possibility of using such a technology in the daily clinical practice is particularly fascinating. The aim of the present study was to assess the effects of the argon plasma treatment on different titanium implant surfaces previously exposed in vitro to bacterial contamination. Material and Methods: Sterile c.p. titanium implant discs with turned (T, Sa: 0.8μm), sandblasted/acid-etched (SAE, Sa: 1.3μm) and titanium plasma sprayed (TPS, Sa: 3.0μm) surface were used in this study. A strain of Ag- gregatibacter a…
Intravitreal dexamethasone implant for cystoid macular edema and inflammation after scleral buckling
2015
Purpose Cystoid macular edema may occur following scleral buckling and therefore deteriorate the visual outcome. Inflammation may be the major causative factor in the development of postoperative cystoid macular edema. This case demonstrates the effectiveness of a dexamethasone implant as a treatment after the onset of choroidal inflammation and cystoid macular edema 6 months following scleral buckling and having visual acuity restored. Methods A 59-year-old phakic woman treated with scleral buckling for macula-off retinal detachment presented 2 months after surgery with cystoid macular edema with choroidal inflammation. Optical coherence tomography and fluorescein angiography were performe…
Implant-specific follow-up imaging of treated intracranial aneurysms: TOF-MRA vs. metal artifact reduced intravenous flat panel computed tomography a…
2017
Aim To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. Methods The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n= 20; clipping: n= 15; coiling + stenting: n= 9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-ima…
Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants.
1997
In the present multi-center study. non-submerged ITI implants were prospectively followed to evaluate their long-term prognosis in fully and partially edentulous patients. In a total of 1003 patients, 2359 implants were consecutively inserted. Following a healing period of 3–6 months, the successfully integrated implants were restored with 393 removable and 758 fixed restorations. Subsequently, all consecutive implants were documented annually up to 8 years. At each examination, the clinical status of all implants was evaluated according to predefined criteria of success. Therefore, the data base allowed the evaluation of 8-year cumulative survival and success rates for 2359 implants. In ad…