Search results for "INDUCTION"
showing 10 items of 769 documents
Torque peak reduction and overload monitoring of induction motors in offshore drilling operations
2015
Current drivetrain design procedures for electric actuation systems operating in offshore conditions typically consider two major requirements: to provide sufficient steady-state and maximum motor torques. As a result of this, no information regarding the transient state (e.g. during motor acceleration) is utilized when selecting drivetrain components. This leads to potentially dangerous situations when motors undergo saturation in these regions due to too high dynamic loads. A common reason for this (apart from lack of information about transient state when designing a drivetrain) is applying trapezoidal reference motion profiles that cause discontinuities in system acceleration and infini…
A Two-Stage Fault Detection and Classification Scheme for Electrical Pitch Drives in Offshore Wind Farms Using Support Vector Machine
2019
Pitch systems are one of the components with the most frequent failure in wind turbines. This paper presents a two-stage fault detection and classification scheme for electric motor drives in wind turbine pitch systems. The presented approach is suitable for application in offshore wind farms with electric pitch systems driven by induction motors as well as permanent magnet synchronous motors. The adopted strategy utilizes three-phase motor current sensing at the pitch drives for fault detection and only when a fault condition is detected at this stage, features extracted from the current signals are transmitted to a support vector machine classifier located centrally to the wind farm. The …
Automatic detection of thermal anomalies in induction motors
2021
The paper proposes a methodology based on Artificial Intelligence techniques for the automatic detection of abnormal thermal distributions in electric motors, to rapidly identify pre-faults or fault conditions. The proposed approach, applied to induction motors of different sizes, installed in waterworks plants, is based on the execution of Thermographic Non-Destructive Tests, which allow identifying abnormal operating conditions without interrupting the ordinary working conditions of the system. Thermographic images of induction motors are acquired at the installation site and with perspectives visible to the operator, which are sometimes partially obstructed. These thermographic images ar…
Dynamical Compensation of the Load Torque in a High-Performance Electrical Drive with an Induction Motor
2018
This paper describes a new method for dynamical estimation of load disturbance in induction motors by using Nonlinear Unknown Input Observers (NUIO). This estimation is then used to compensate dynamically the load torque in a Field Oriented Control (FOC) induction motor drive to increase its load-rejection capability. The method has been verified both in simulation and experimentally on a experimental rig.
Intracranial measurement of current densities induced by transcranial magnetic stimulation in the human brain
2003
Transcranial magnetic stimulation (TMS) is a non-invasive technique that uses the principle of electromagnetic induction to generate currents in the brain via pulsed magnetic fields. The magnitude of such induced currents is unknown. In this study we measured the TMS induced current densities in a patient with implanted depth electrodes for epilepsy monitoring. A maximum current density of 12 microA/cm2 was recorded at a depth of 1 cm from scalp surface with the optimum stimulation orientation used in the experiment and an intensity of 7% of the maximal stimulator output. During TMS we recorded relative current variations under different stimulating coil orientations and at different points…
Comparative Determinations of Magnetic Induction in AC and DC Circuits
2019
The influence of the electromagnetic field on the human body, although still heavily studied, can have long-term negative effects. The static electromagnetic field is generated by a continuous current source and has a current flow characteristic conventionally set + from -. The variable electromagnetic field is produced by the alternating current and has the ability to change its direction over time with a frequency of 50 or 60 Hz. It is considered that the non-hazardous limit value for the magnetic field (according to Federal Office for Radiation Security in Germany) is 100 microT for 50 Hz and 83 microT for 60 Hz. For the electric field, the exposure limit value is 5kV/m. Electromagnetic …
Sensorless variable speed single-phase induction motor drive system based on direct rotor flux orientation
2012
The single-phase induction motor (SPIM) is one of the electrical machines more used in the World, and can be found in several fractional and sub-fractional horsepower applications in houses, offices, shoppings, farms, and industries. The introduction of more sophisticated applications has required the use of variable speed drives for SPIM, where the adoption of sensorless techniques is the more reasonable option for speed control due to the low cost of this electrical machine. A proposal for sensorless variable speed SPIM drive based on direct rotor field orientation techniques is presented in this paper. None transformation is used in order to eliminate the asymmetry of the stator windings…
Robust Active Disturbance Rejection Control of Induction Motor Systems Based on Additional Sliding-Mode Component
2017
This paper deals with motion control systems with induction motor, subject to severe requirements on both dynamics and steady-state behavior. The proposed control methodology could be viewed as an advancement of the standard field oriented control. It consists of two control loops, i.e., the rotor flux and the speed control loops, designed using the active disturbance rejection control method, with the aim to cope with both exogenous and endogenous disturbances, which are estimated by means of two linear extended state observers and then compensated. Moreover, with the aim of achieving total robustness, a sliding-mode based component is designed, in order to take into account disturbance es…
Sensorless variable speed single-phase induction motor drive system
2012
It is usual find single-phase induction motor (SPIM) in several house, office, shopping, farm, and industry applications, which are become each time more sophisticated and requiring variable speed drives. Considering the low cost of this machine, the adoption of sensorless speed control is the more reasonable option for SPIM drives. This paper presents a proposal for sensorless variable speed SPIM drive based on direct rotor field orientation techniques. An observer based on two independent linear close-loop control systems provides the estimation of the rotor flux and speed from the measurements of the stator currents and voltages. These estimatives are used by close-loop systems for speed…
Speed control of tubular linear induction motors for industrial automated applications
2016
The Tubular Linear Induction Machine (TLIM) has acquired great relevance over the past years for industrial automated applications. For this purpose, the complete modeling, simulation and determination of the parameters of a TLIM is presented in this paper. In addition, the TLIM speed control for this specific application is here described. In order to verify the performances of the proposed system, a test bench has been setup and good agreement is shown from the comparison between measured and simulated results.