Measurements on partial discharge in on‐site operating power transformer: a case study
2018
This study presents the case study of a substation in-service power transformer referred to the on-site partial discharge (PD) detection and evaluation methods. An original methodology for simultaneous application of three methods is proposed: electrical, acoustic and ultra-high frequency. Transformer is powered by the power grid and no external generator is required according to the proposed methodology. Furthermore, several possibilities of applying these concurrent measurements and benefits of such solution in terms of result interpretation, interference resistance and on-site measurement applicability are indicated. The proposed methodology allows for a fast, accurate and secure PD diag…
Modeling Stator Winding Inter-Turn Short Circuit Faults in PMSMs including Cross Effects
2020
Author's accepted manuscript. © 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. This paper presents a detailed analysis of stator winding inter-turn Short Circuit (ITSC) faults, taking the cross effects in the three phases of a permanent magnet synchronous motor (PMSM) into account by considering insulation degradation resistances. A PMSM with series coils in eac…
A General Mathematical Formulation for the Determination of Differential Leakage Factors in Electrical Machines with Symmetrical and Asymmetrical Ful…
2018
This paper presents a simple and general mathematical formulation for the determination of the differential leakage factor for both symmetrical and asymmetrical full and dead-coil windings of electrical machines. The method can be applied to all multiphase windings and considers Gorges polygons in conjunction with masses geometry in order to find an easy and affordable way to compute the differential leakage factor, avoiding the adoption of traditional methods that refer to the Ossanna's infinite series, which has to be obviously truncated under the bound of a predetermined accuracy. Moreover, the method described in this paper allows the easy determination of both the minimum and maximum v…
Piecewise Affine (PWA) Modeling and Switched Damping Control of Two-Inertia Systems with Backlash
2018
Backlash degrades positioning accuracy and can induce mechanical wear and breakage by collisions. Therefore, a lot of studies have been conducted on backlash compensation. The simplest control method for the impact attenuation is torsional damping addition by feedback of torsional velocity. This paper reveals the advantages and disadvantages of the torsional damping addition. Based on the analyses, a novel switched damping control is proposed to realize the responses with smaller overshoot while attenuating the impact. The mechanical system and the proposed controller are described as piecewise affine systems for analyses. The performance of the proposed method is compared with a linear dam…
Maximum Torque Per Ampere control algorithm for low saliency ratio interior permanent magnet synchronous motors
2017
This paper presents an investigation on the comparison between the Maximum Torque Per Ampere (MTPA) and the Field Orientation Control (FOC) algorithms for interior permanent magnet synchronous machines (IPMSMs). In particular, this study was carried out on a small-power IPMSM with low salience ratio. Both control algorithms have been implemented in the Matlab/Simulink environment, obtaining promising results.
Pulsed Electro-Acoustic Method for specimens and cables employed in HVDC systems: Some feasibility considerations
2018
Recent experiments on the use of the PEA method for testing dielectric materials in specimens and comparison with a detailed model provide an insight of the phenomenon and suggest the need of adopting similar models also for cables. What is said is even more important considering the possible future adoption of the PEA methodology to test DC cables for Pre-Qualification and Type Tests. The use of an accurate model of the PEA cell used for testing specimens and related experiments prove that the thickness of the different parts composing the PEA setup is a basic element for providing accurate charge reading and interpretation of the phenomenon. Both simulation and experimental results, carri…
Flexible and efficient computer-aided design tool for advanced comb-line rectangular waveguide filters
2015
A very flexible and efficient computer-aided design CAD tool, specifically suited for advanced comb-line rectangular waveguide filters, is presented in this work. The developed software tool, which makes use of a full-wave analysis technique based on the Boundary Integral-Resonant Mode Expansion method, allows loading the considered comb-line resonators with any number of radially symmetrical partial-height metallic posts. The implemented CAD tool also allows dealing with coupling windows of arbitrary cross-section, thus drastically enhancing the flexibility of the CAD process. The excitation of the analyzed components, which is performed using generalized coaxial probes, has also been inte…
Early detection and classification of bearing faults using support vector machine algorithm
2017
Bearings are one of the most critical elements in rotating machinery systems. Bearing faults are the main reason for failures in electrical motors and generators. Therefore, early bearing fault detection is very important to prevent critical system failures in the industry. In this paper, the support vector machine algorithm is used for early detection and classification of bearing faults. Both time and frequency domain features are used for training the support vector machine learning algorithm. The trained classier can be employed for real-time bearing fault detection and classification. By using the proposed method, the bearing faults can be detected at early stages, and the machine oper…
Investigation and reduction of losses on inverter-fed induction motors
2017
An electric motor is more effective and flexible when supplied by a frequency converter. The frequency converter not only produces the fundamental voltage but also a set of higher harmonics which cause additional losses in the motor. Losses in the frequency converter are normally neglected in the drive dimensioning due to insufficient data available from manufacturers. Motor's losses can be reduced by increasing the switching frequency of frequency converters. An increase of the switching frequency may result in higher losses in the frequency converter. This work investigates analytically and experimentally the dependence of the losses of modern motor and frequency converter on a switching …
An exact method for the determination of differential leakage factors in electrical machines with non-symmetrical windings
2016
An exact and simple method for the determination of differential leakage factors in polyphase ac electrical machines with non-symmetrical windings is presented in this paper. The method relies on the properties of Gorges polygons that are used to transform an infinite series expressing the differential leakage factor into a finite sum in order to significantly simplify the calculations. Some examples are shown and discussed in order to practically demonstrate the effectiveness of the proposed method.