Search results for "INTEGRAL"
showing 10 items of 902 documents
The mapping properties of the radiosity operator along an edge
2002
In this article we study the radiosity operator along an edge between two adjacent half-planes. First we show that the radiosity operator is invertible in a whole scale of anisotropic Sobolev spaces. In the absence of any shadows we are able to derive regularity properties of the solution, which depend only on the angle between the half-planes, the reflectivity coefficients and the right-hand side. This work can be considered as a supplement to the article of Rathsfeld (Mathematical Methods in the Applied Sciences 1999; 22: 217–241). Copyright © 2002 John Wiley & Sons, Ltd.
Sciacca Michele Federico
2010
Voce di dizionario. Ampia descrizione dell'opera e della posizione filosofica di Sciacca attraverso la ricostruzione dei diversi momenti del loro sviluppo, con appendice bio-bibliografica.
Membrane protein integration into the endoplasmic reticulum
2011
Most integral membrane proteins are targeted, inserted and assembled in the endoplasmic reticulum membrane. The sequential and potentially overlapping events necessary for membrane protein integration take place at sites termed translocons, which comprise a specific set of membrane proteins acting in concert with ribosomes and, probably, molecular chaperones to ensure the success of the whole process. In this minireview, we summarize our current understanding of helical membrane protein integration at the endoplasmic reticulum, and highlight specific characteristics that affect the biogenesis of multispanning membrane proteins.
Targeting and membrane insertion into the endoplasmic reticulum membrane of Saccharomyces cerevisiae essential protein Rot1
2010
Rot1 is an essential yeast protein that has been related to cell wall biosynthesis, actin cytoskeleton dynamics and protein folding. Rot1 is an N -glycosylated protein anchored to the nuclear envelope–endoplasmic reticulum (ER) membrane by a transmembrane domain at its C-terminal end. Rot1 is translocated to the ER by a post-translational mechanism. Here, we investigate the protein domain required to target and translocate Rot1 to the ER membrane. We found that several deletions of the N-terminal region of Rot1 prevented neither membrane targeting nor the insertion of this protein. Interestingly, we obtained the same results when different truncated forms in the C-terminal transmembrane dom…
On essential maximality of linear pseudo-differential operators
1989
Display of travelling 3D scenes from single integral-imaging capture
2016
Integral imaging (InI) is a 3D auto-stereoscopic technique that captures and displays 3D images. We present a method for easily projecting the information recorded with this technique by transforming the integral image into a plenoptic image, as well as choosing, at will, the field of view (FOV) and the focused plane of the displayed plenoptic image. Furthermore, with this method we can generate a sequence of images that simulates a camera travelling through the scene from a single integral image. The application of this method permits to improve the quality of 3D display images and videos.
Algorithms for transforming an integral photography into a plenoptic picture
2013
We report a simple algorithm for transforming the set of elemental images captured with an integral-photography set up, into the set of micro-images ready to be projected into an integral-imaging monitor. The method is based in the transposing relation between an integral photography and a plenoptic picture. The reported technique permits to adapt the integral images to the resolution and size of the monitor.
Formation of real, orthoscopic integral images by smart pixel mapping.
2005
Integral imaging systems are imaging devices that provide 3D images of 3D objects. When integral imaging systems work in their standard configuration the provided reconstructed images are pseudoscopic; that is, are reversed in depth. In this paper we present, for the first time we believe, a technique for formation of real, undistorted, orthoscopic integral images by direct pickup. The technique is based on a smart mapping of pixels of an elemental-images set. Simulated imaging experiments are presented to support our proposal.
Fully programmable display parameters in integral imaging by smart pseudoscopic-to-orthoscopic conversion
2011
Previously, we reported a digital technique for formation of real, non-distorted, orthoscopic integral images by direct pickup. However the technique was constrained to the case of symmetric image capture and display systems. Here, we report a more general algorithm which allows the pseudoscopic to orthoscopic transformation with full control over the display parameters so that one can generates a set of synthetic elemental images that suits the characteristics of the Integral-Imaging monitor and permits control over the depth and size of the reconstructed 3D scene.
A nicely behaved singular integral on a purely unrectifiable set
2001
We construct an example of a purely 1-unrectifiable AD-regular set E in the plane such that the limit