Search results for "IPM"
showing 10 items of 1361 documents
Comparisons of Musculoskeletal Complaints and Data Entry Between a Sitting and a Sit-Stand Workstation Paradigm
2009
Background: Seated working positions are often regarded as a cause for discomfort in the musculoskeletal system. Performing work in different working positions—that is, alternating between sitting and standing (sit-stand workstation paradigm)—could help reduce physical complaints. Objective: The questions were whether performing office work partly in a standing position leads to reduced complaints and whether standing would change the efficiency of data entry office work. Method: We investigated the effect of a sit-stand workstation paradigmd during experimental data entry office work on physical and psychological complaints and data entry efficiency by conducting a randomized controlled t…
Double-balloon enteroscopy (push-and-pull enteroscopy) of the small bowel: feasibility and diagnostic and therapeutic yield in patients with suspecte…
2005
Background Double-balloon enteroscopy (push-and-pull enteroscopy) is a new method that allows complete visualization, biopsy, and treatment in the small bowel. This study evaluated the feasibility and the diagnostic and the therapeutic yield of double-balloon enteroscopy (push-and-pull enteroscopy) in comparison with current imaging methods. Methods Between March 2003 and November 2004, 248 consecutive double-balloon enteroscopies (push-and-pull enteroscopies) were performed in a prospective study in 137 patients with suspected small-bowel disease (60 women, 77 men; mean age 56.6 ± 17.8 years), most with chronic GI bleeding (66%). The examinations were carried out after negative evaluations…
Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers
2005
Background/aim: TGDc-01 is a new, portable, transpalpebral tonometry device. The aim of this study was to evaluate the reproducibility of this method, including intraobserver and interobserver deviations, and to compare the results with those of Goldmann applanation tonometry and palpation of intraocular pressure (IOP). Methods: A total of 40 eyes of 20 healthy volunteers were included. Two independent parallel observers (1 and 2) performed three replicate measurements per eye, respectively, both using TGDc01 tonometry, one observer (3) performed three replicate measurements using Goldmann applanation tonometry, and one observer (4) measured the IOP via palpation. Intraindividual deviations…
Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
2013
Purpose To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and methods Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Saf…
Endoluminal therapy of GERD with a new endoscopic suturing device
2005
Background Endoscopic, endoluminal therapy might be an alternative treatment option in light of the costs of proton pump inhibitor therapy and possible complications after laparoscopic surgery. The aim of the current study was to assess the efficacy and the safety of a new endoluminal suture device (ESD) in pig models and humans. Secondly, 3 and 6 months' follow-ups were performed, and possible complications and their management were evaluated. Methods In the preclinical phase of the study, suturing procedures were practiced and evaluated in 8 pig models (Erlanger Endo Trainer). In the clinical phase, 20 patients with mild esophagitis, small or no hiatal hernia, and signs of abnormal acid e…
Tidal Volume Estimation during Helmet Noninvasive Ventilation: an Experimental Feasibility Study
2019
AbstractWe performed a bench (BS) and human (HS) study to test the hypothesis that estimation of tidal volume (VT) during noninvasive helmet pressure support ventilation (nHPSV) would be possible using a turbine driven ventilator (TDV) coupled with an intentional leak single-limb vented circuit. During the BS a mannequin was connected to a lung simulator (LS) and at different conditions of respiratory mechanics, positive end expiratory pressure (PEEP) levels and leaks (30, 50 and 80 L/min). All differences were within the 95% limits of agreement (LoA) in all conditions in the Bland-Altman plot. The overall bias (difference between VT measured by TDV and LS) was 35 ml (95% LoA 10 to 57 ml), …
Light distortion of soft multifocal contact lenses with different pupil size and shape
2020
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…
Measurement of EMG activity with textile electrodes embedded into clothing.
2007
Novel textile electrodes that can be embedded into sports clothing to measure averaged rectified electromyography (EMG) have been developed for easy use in field tests and in clinical settings. The purpose of this study was to evaluate the validity, reliability and feasibility of this new product to measure averaged rectified EMG. The validity was tested by comparing the signals from bipolar textile electrodes (42 cm(2)) and traditional bipolar surface electrodes (1.32 cm(2)) during bilateral isometric knee extension exercise with two electrode locations (A: both electrodes located in the same place, B: traditional electrodes placed on the individual muscles according to SENIAM, n=10 person…
Determining the location of the body׳s center of mass for different groups of physically active people
2013
The purpose of the present study was to compare the location of the body center of mass (CoM) determined by using a high accuracy reaction board (RB) and two different segment parameter models for motion analysis (Dempster, 1955, DEM and de Leva, 1996 adjusted from Zatsiorsky and Seluyanov, ZAT). The body CoM (expressed as percentage of the total body height) was determined from several subjects including athletes as well as physically active students and sedentary people. Some significant differences were found in the location of the body CoM between the used segment models and the reaction board method for all male subjects (n=58, 57.03±0.79%, 56.20±0.76% and 57.60±0.76% for RB, ZAT and D…
Effects of the Breathe Right Nasal Strips on Nasal Ventilation
1997
The Breathe Right nasal strips are more and more commonly used, mainly by athletes, who hope to enhance their physical performance in competition and training. The effect of the device in such situations is uncertain and perhaps somewhat controversial. To investigate the effects of the nasal strips on nasal ventilation, 20 Caucasian individuals were objectively assessed using anterior rhinomanometry and acoustic rhinometry. The results showed a significant increase in all subjects of transnasal airflow and in the average cross-sectional area of the nasal cavity that quantifies objectively the subjective impression of improved nasal breathing. In such patients where an improvement in nasal …