Search results for "IPM"

showing 10 items of 1361 documents

Mechanical rotational thrombectomy in long femoropopliteal artery and stent occlusion in COVID-19 patient: Case report

2021

Abstract Introduction Coronavirus disease-19 (COVID-19) has been increasingly associated with thromboembolic complications. COVID-19 infection has a thrombogenic potential for stents. Herein, we report a case of stent thrombosis in diabetic obese patient COVID-19 positive where was previously released a Multilayer Flow Modulator stent (MFM) for large popliteal aneurysm. Case report A 78-year-old male was referred to our hospital for fever and acute pain in the left leg. At history, the same patient had endovascular procedure for a large symptomatic popliteal aneurysm, treated through release of three MFM. The pulmonary CT scan showed COVID-19 infection with confirm of rhino-laryngeal swab. …

medicine.medical_specialtymedicine.medical_treatmentCase ReportRevascularizationSettore MED/22 - Chirurgia VascolarePopliteal aneurysm03 medical and health sciences0302 clinical medicinemedicineMultilayer Flow Modulator stentAcute limb ischemiacardiovascular diseasesbusiness.industryCOVID-19Stentequipment and suppliesDebulkingmedicine.diseaseArterial occlusionThrombosisSurgeryCathetersurgical procedures operativemedicine.anatomical_structure030220 oncology & carcinogenesisRotarex030211 gastroenterology & hepatologySurgeryMechanical thrombectomybusinessArteryInternational Journal of Surgery Case Reports
researchProduct

“Unlucky punch”: unexpected annular rupture during TAVR and successful treatment

2021

Although rare, annular rupture in TAVR is a feared and often unpredictable complication with relevant impact on in-hospital prognosis. Severe annular calcification is a common risk factor for annular rupture. We report on a case of annular rupture during TAVR with a balloon-expanded prosthesis in the absence of any annular calcification in the planning CT scan and illustrate the proposed pathomechanism as well as its successful immediate surgical management.

medicine.medical_specialtymedicine.medical_treatmentComputed tomographyProsthesis DesignProsthesisTranscatheter Aortic Valve ReplacementHumansMedicineRadiology Nuclear Medicine and imagingcardiovascular diseasesRisk factorHeart Valve Prosthesis Implantationmedicine.diagnostic_testbusiness.industryCalcinosisAortic Valve Stenosisequipment and suppliesmedicine.diseaseTreatment OutcomeAortic ValveHeart Valve Prosthesiscardiovascular systemsense organsRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicineComplicationbusinessCalcificationEchocardiography
researchProduct

Endovascular Repair of Contained Abdominal Aortic Aneurysm Rupture Using a Bilateral D-Shaped Stent System

2017

To report the first case of the treatment of a contained aortic aneurysm rupture using a bilateral D-shaped endovascular stent graft system.

medicine.medical_specialtymedicine.medical_treatmentcontained ruptured aneurysm030204 cardiovascular system & hematologySystem a03 medical and health sciences0302 clinical medicineAneurysmAortic aneurysm rupturemedicineEVARcardiovascular diseasesAAAbusiness.industryStent030229 sport sciencesGeneral Medicineequipment and suppliesmedicine.diseaseAbdominal aortic aneurysmSurgerysurgical procedures operativeaneurysmcardiovascular systemSurgeryCardiology and Cardiovascular MedicinebusinessVascular and Endovascular Surgery
researchProduct

Evaluation of the predictive value of the bleeding prediction score VTE‐BLEED for recurrent venous thromboembolism

2019

Abstract Introduction VTE‐BLEED is a validated score for identification of patients at increased risk of major bleeding during extended anticoagulation for venous thromboembolism (VTE). It is unknown whether VTE‐BLEED high‐risk patients also have an increased risk for recurrent VTE, which would limit the potential usefulness of the score. Methods This was a post hoc analysis of the randomized, double‐blind, placebo‐controlled PADIS‐PE trial that randomized patients with a first unprovoked pulmonary embolism (PE) initially treated during 6 months to receive an additional 18‐month of warfarin vs. placebo. The primary outcome of this analysis was recurrent VTE during 2‐year follow‐up after ant…

medicine.medical_specialtyrecurrencemedicine.drug_classvenous thromboembolismInternal medicinemedicineCumulative incidencecardiovascular diseasesanticoagulation therapylcsh:RC633-647.5business.industryAnticoagulantHazard ratioWarfarinlcsh:Diseases of the blood and blood-forming organsprediction scoreHematologyBleedbleedingequipment and suppliesmedicine.diseaseConfidence intervalPulmonary embolismDiscontinuationOriginal ArticlebusinessOriginal Articles: Thrombosismedicine.drugResearch and Practice in Thrombosis and Haemostasis
researchProduct

Increased sulfate availability in saline water promotes hydrogen sulfide production in fish organic waste

2020

The risk of hydrogen sulfide (H2S) production can be a challenge in marine land-based recirculating aquaculture systems (RAS). Hydrogen sulfide is a toxic gas that can cause massive fish mortality even at low concentrations, and in addition, serious odour problems in the surroundings. It is a bacterial by-product originating from the degradation of organic matter in sulfur-rich waters such as marine waters. In order to hinder H2S production in marine land-based RAS, more information on the H2S production conditions and the associated microbiology is needed. In this study, the production of H2S from rainbow trout (Oncorhynchus mykiss) organic waste was examined using a novel H2S measurement …

merivesisulfate reducing bacteriasulfaatitrikkivetyhydrogen sulfidesulfateorgaaninen ainesequipment and suppliesorganic matterseawater
researchProduct

An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study.

2019

Background and Objectives: Within the clinical evaluation of multiple pathologies of the lower limb, the measurement of range of motion (ROM) of its joints is fundamental. To this end, there are various tools, from the goniometer as a reference to more recent devices such as inclinometry-based applications, photo capture applications, or motion capture systems. This study aimed to assess the validity, intra-rater, and inter-rater reliability of the VeloFlex system (VS), which is a new camera-based tool designed for tracking joint trajectories and measuring joint ROM. Materials and Methods: Thirty-five healthy volunteers (16 females

musculoskeletal diseasesAdultMaleMedicine (General)AdolescentCross-sectional studyConcurrent validityeducationMesurament -- InstrumentsArticlerange of motionsymbols.namesakeYoung AdultR5-920articular goniometryHealthy volunteersMedicineHumanslower extremity; range of motion; reproducibility of results; articular goniometryRange of Motion ArticularReliability (statistics)Leg -- DiseasesOrthodonticsObserver VariationArthrometry Articularbusiness.industryOrthopedic EquipmentReproducibility of ResultsGeneral MedicineMiddle AgedPearson product-moment correlation coefficientHealthy VolunteersStandard errorCross-Sectional StudiesLower ExtremityCames -- MalaltiesGoniometersymbolsMeasuring instrumentsFemaleRange of motionbusinessMedicina (Kaunas, Lithuania)
researchProduct

A ten-year follow-up of the Reflection cementless acetabular component.

2008

We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…

musculoskeletal diseasesAdultmedicine.medical_specialtyAcetabulum; Adult; Aged; Aged 80 and over; Arthroplasty Replacement Hip; Bone Cements; Equipment Failure Analysis; Follow-Up Studies; Hip Joint; Humans; Middle Aged; Osteoarthritis Hip; Prosthesis Design; Prosthesis Failure; Statistics as Topic; Time Factors; Hip ProsthesisTime FactorsArthroplasty Replacement HipStatistics as TopicProsthesis DesignOsteoarthritis HipmedicineHumansOrthopedics and Sports MedicineSurvival analysisPelvisFixation (histology)AgedAged 80 and overbusiness.industryBone CementsAcetabulumMiddle AgedConfidence intervalSurgeryProsthesis FailureEquipment Failure AnalysisReflection acetabular component hipmedicine.anatomical_structureAcetabular componentRadiological weaponCohortOrthopedic surgerySurgeryHip JointHip ProsthesisbusinessFollow-Up StudiesThe Journal of bone and joint surgery. British volume
researchProduct

In vitro comparison of the efficacy of two fractured implant-prosthesis screw extraction methods: Conventional versus mechanical.

2019

Abstract Statement of problem Implant-supported prostheses may be subject to esthetic, biological, or mechanical complications. Protocols for dealing with these mechanical problems are sparse. Purpose The purpose of this in vitro study was to compare the efficacy of a mechanical system for extracting fractured implant-prosthesis screws with the conventional method. Material and methods A total of 60 screws were divided into 2 groups according to their morphology (flat screws with a smooth shaft and threaded apical area and screws with a completely threaded body) and subjected to fatiguing and static load testing until fracture. The specimens were assigned to 3 operators with varying levels …

musculoskeletal diseasesDental ImplantsUltrasound deviceMaterials scienceImplant prosthesisBone Screws030206 dentistryThread (computing)Esthetics Dentalmusculoskeletal systemequipment and suppliescomputer.software_genreExtractor03 medical and health sciencesLoad testingsurgical procedures operative0302 clinical medicineCoronal planeExtraction methodsOral SurgerycomputerFracture typeBiomedical engineeringThe Journal of prosthetic dentistry
researchProduct

Biomechanical effectiveness of a distraction-rotation knee brace in medial knee osteoarthritis: preliminary results.

2013

Abstract Background Non-pharmacological therapies are recommended for the care of knee osteoarthritis patients. Unloader knee braces provide an interesting functional approach, which aims to modulate mechanical stress on the symptomatic joint compartment. We aimed to confirm the biomechanical effects and evaluate functional benefits of a new knee brace that combines a valgus effect with knee and tibial external rotation during gait in medial osteoarthritis patients. Methods Twenty patients with unilateral symptomatic medial knee osteoarthritis were included and they performed two test sessions of 3D gait analysis with and without the brace at the initial evaluation (W0) and after 5weeks (W5…

musculoskeletal diseasesMalemedicine.medical_specialtyWOMACVisual Analog ScaleOsteoarthritisPhysical medicine and rehabilitationmedicineHumansOrthopedics and Sports MedicineProspective StudiesGaitBracesbiologybusiness.industryEquipment DesignMiddle AgedOsteoarthritis Kneemusculoskeletal systembiology.organism_classificationmedicine.diseaseGaitBraceBiomechanical PhenomenaPreferred walking speedValgusmedicine.anatomical_structurePatient SatisfactionGait analysisFemaleAnklebusinesshuman activitiesLocomotionThe Knee
researchProduct

Cemented and screw-retained implant-supported single-tooth restorations in the molar mandibular region: A retrospective comparison study after an obs…

2015

Objectives: The aim of this study was to evaluate the survival and compare the appearance of different mechanical and biological complications, in screw-retained and cemented-retained single-tooth implant-supported restorations localized in the molar mandibular region, over a period of 1 to 4 years. Material and Methods: A retrospective study was carried out with a total of eighty implant-supported restorations, which were placed in eighty patients for prosthetic rehabilitation of a mandibular molar. Forty patients were rehabilitated with a cemented-retained restoration and the other forty with a screw-retained restoration. The presence of the following complications was recorded for both t…

musculoskeletal diseasesMolarDentistryOdontologíaMucositisMedicineGeneral DentistryProsthetic DentistryImplantes dentalesbusiness.industryResearchMandibular regionSoft tissueRetrospective cohort studySingle tooth:CIENCIAS MÉDICAS [UNESCO]musculoskeletal systemequipment and suppliesmedicine.diseaseCiencias de la saludsurgical procedures operativeUNESCO::CIENCIAS MÉDICASComparison studybusinessComplication
researchProduct