Clinical evaluation of piezoelectric ear surgery

2008

We evaluated the use of piezoelectric surgery (Piezosurgery; Mectron Medical Technology; Carasco, Genoa, Italy) as a means of avoiding some complications of osteotomy and osteoplasty in otologic surgery, particularly in classic canal-wall-up mastoidectomy. Piezoelectric surgery is a recently developed system for cutting bone with microvibrations created by the piezoelectric effect. This effect occurs when an electric current is passed through certain ceramics and crystals, causing them to oscillate at ultrasonic frequencies. Our study population was made up of 20 adults with unilateral chronic otitis media. In all patients, piezoelectric surgery allowed for effective, precise, safe, easy, …

AdultMaleOsteoplastymedicine.medical_specialtymedicine.medical_treatmentOsteotomy03 medical and health sciences0302 clinical medicineHumansMedicine030223 otorhinolaryngologyPiezosurgeryPiezoelectric surgerybusiness.industryEarEquipment DesignMiddle AgedSurgeryPiezosurgery otologic surgery canal-wall-up mastoidectomySettore MED/31 - OtorinolaringoiatriaOtorhinolaryngology030220 oncology & carcinogenesisFemaleOtologic Surgical ProceduresbusinessClinical evaluation
researchProduct

Diffusion weighted magnetic resonance imaging in the diagnosis of reversible ischaemic deficits of the brainstem

2002

Objectives: To evaluate the sensitivity of diffusion weighted magnetic resonance imaging (MRI) for the diagnosis of clinically suspected reversible ischaemic deficits of the brainstem. Methods: A total of 158 consecutive patients presenting with acute signs of brainstem dysfunction were investigated using EPI diffusion weighted MRI within 24 hours of the onset of symptoms. High resolution T1 and T2 weighted imaging was performed as a follow up after a median of six days Results: Fourteen of the 158 patients had a complete clinical recovery within 24 hours (transitory ischaemic attack (TIA)), and 19 patients recovered in less than one week (prolonged reversible neurological deficit (RIND)). …

AdultMalePapermedicine.medical_specialtyIschemiaSensitivity and SpecificityCentral nervous system diseaseDiagnosis DifferentialRisk FactorsInternal medicinemedicineHumansProspective StudiesStrokeAgedAged 80 and overNeurologic ExaminationVascular diseasebusiness.industryMiddle Agedmedicine.diseaseequipment and suppliesMagnetic Resonance ImagingDiffusion-Weighted Magnetic Resonance ImagingSurgeryStrokePsychiatry and Mental healthEditorial CommentaryIschemic Attack TransientAcute DiseaseCardiologySurgeryFemaleNeurology (clinical)BrainstemT2 weightedbusinesshuman activitiesDiffusion MRIBrain Stem
researchProduct

On-eye optical quality of daily disposable contact lenses for different wearing times

2012

Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…

AdultMalePoint spread functionOptics and PhotonicsCorneal Wavefront AberrationTime Factorsgenetic structuresZernike polynomialsVisual AcuityPupillaw.inventionYoung Adultsymbols.namesakeOpticslawOptical transfer functionAberrometryMyopiaHumansDisposable EquipmentMathematicsWavefrontbusiness.industryAberrometryContact Lenses Hydrophiliceye diseasesSensory SystemsLens (optics)OphthalmologysymbolsFemalesense organsSpatial frequencybusinessOptometryOphthalmic and Physiological Optics
researchProduct

An alternative clinical routine for subjective refraction based on power vectors with trial frames.

2016

PURPOSE Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. METHODS An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented …

AdultMaleRefractive errorCorrelation coefficientAdolescentVisual AcuityAstigmatismRefraction Ocular01 natural sciences010309 optics03 medical and health sciencesYoung Adult0302 clinical medicineOptics0103 physical sciencesmedicineHumansPhoropterMathematicsMonocularbusiness.industryOrientation (computer vision)Vision TestsEquipment Designmedicine.diseaseRefractive ErrorsSubjective refractionRefractionSensory SystemsOphthalmologyEyeglasses030221 ophthalmology & optometryFemalebusinessAlgorithmOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation

2003

Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…

AdultMaleRefractive errorVisual acuityRotationgenetic structuresmedicine.medical_treatmentEmmetropiaIntraocular lensPhakic intraocular lensLens Implantation IntraocularmedicineHumansPostoperative PeriodProspective StudiesDioptreLenses Intraocularbusiness.industryAstigmatismEquipment DesignMiddle AgedRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresToric lensOphthalmologyMeridian (perimetry visual field)OptometryFemaleSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Prevention of ventricular catheter obstruction and slit ventricle syndrome by the prophylactic use of the Integra antisiphon device in shunt therapy …

2010

Object This 25-year follow-up study was performed on 120 children with hypertensive hydrocephalus to evaluate the influence of the early prophylactic implantation of the Integra antisiphon device (ASD, Integra Neurosciences Ltd.) on the rate of proximal shunt obstructions and the frequency of symptomatic slit ventricle syndrome (SVS). The adaptability of the ASD to growth, proper positioning of the ASD as a necessity for its successful performance, and the 3 phases of SVS development are discussed. Method Since 1978, the ASD has consistently been implanted either at the time of primary shunt insertion (66 neonates, mean follow-up 11 years) or during revisions of preexisting shunts (54 chil…

AdultMaleReoperationmedicine.medical_specialtyAdolescentIntracranial PressureHydrostatic pressureInfant Premature DiseasesSlit Ventricle SyndromeCentral nervous system diseaseYoung AdultPostoperative ComplicationsRisk FactorsHydrostatic PressuremedicineHumansYoung adultChildbusiness.industryInfant NewbornInfantEquipment DesignGeneral Medicinemedicine.diseaseSlit Ventricle SyndromeCerebrospinal Fluid ShuntsHydrocephalusSurgeryEquipment Failure AnalysisCatheterEl NiñoChild PreschoolFemaleIntracranial HypertensionbusinessShunt (electrical)Follow-Up StudiesHydrocephalusJournal of Neurosurgery: Pediatrics
researchProduct

A dangerous design for a mountain bike.

2001

The case of a man’s death as a consequence of an accident with a mountain bike was examined. Despite only slight external injuries, a general examination revealed the existence of a rupture of the diaphragm which was the ultimate cause of death. The discussion reconstructs the way the accident occurred and briefly analyses the consequences of safety design in two-wheeled vehicles.

AdultMaleRuptureEngineeringbusiness.industrySafety designDiaphragmDiaphragm (mechanical device)Equipment DesignPathology and Forensic MedicineBicyclingCause of DeathForensic engineeringHumansbusinesshuman activitiesCause of deathInternational journal of legal medicine
researchProduct

Towards Improved Healthcare Performance: Examining Technological Possibilities and Patient Satisfaction with Wireless Body Area Networks

2009

Published version of an article from the journal: Journal of Medical Systems. he original publication is available at Springerlink. http://dx.doi.org/10.1007/s10916-009-9291-8 This paper investigates the benefits of using less intrusive wireless technologies for heart monitoring. By replacing well established heart monitoring devices (i.e. Holter) with wireless ECG based Body Area Networks (BAN), improved healthcare performance can be achieved, reflected in (1) high quality ECG recordings during physical activities and (2) increased patient satisfaction. A small scale clinical trial was conducted to compare both technologies and the results illustrate that the wireless ECG monitor was able …

AdultMaleTelemedicineAdolescentComputer scienceRemote patient monitoringmedicine.medical_treatmentmedia_common.quotation_subjecteducationMedicine (miscellaneous)Health InformaticsHealth informaticsYoung AdultPatient satisfactionHealth Information ManagementmedicineHumansWirelessVDP::Medical disciplines: 700::Health sciences: 800::Health service and health administration research: 806ComputerSystemsOrganization_SPECIAL-PURPOSEANDAPPLICATION-BASEDSYSTEMSQuality (business)cardiovascular diseasesChildAgedmedia_commonbusiness.industryLocal area networkArrhythmias CardiacVDP::Technology: 500::Information and communication technology: 550Middle AgedLocal Area Networksequipment and suppliesTelemedicineRisk analysis (engineering)Patient SatisfactionElectrocardiography AmbulatoryFemaleCardiac monitoringbusinessTelecommunicationsInformation Systems
researchProduct

Local Gingival Blood Flow at Healthy and Inflamed Sites Measured by Laser Doppler Flowmetry

2006

This investigation aimed to: 1) develop a method to obtain reproducible laser Doppler flow readings (LDFRs) at the gingiva of the maxillary front teeth; 2) evaluate regional gingival blood flow (GBF) in healthy gingiva by laser Doppler flowmetry; 3) compare hand-held LDFR (H-LDFR) with splint LDFR (S-LDFR); and 4) monitor changes in GBF in experimental gingivitis (EG) and chronic gingivitis (CG).The LDFR, gingival index (GI), and plaque index (PI) were measured at 13 gingival sites (teeth #6 to #11) in 10 healthy volunteers (five males and five females), 23 to 34 years of age, over a period of 12.5 +/- 3.27 days employing a partial-mouth EG model and in 11 patients (three males and eight fe…

AdultMaleToothbrushingCuspidPlaque indexGingivaDentistryGingivitisHealthy volunteersLaser-Doppler FlowmetryMaxillaHumansMedicineLaser doppler flowbusiness.industryDental Plaque IndexReproducibility of ResultsEquipment DesignBlood flowMiddle AgedLaser Doppler velocimetryGingivitisIncisorGingival indexRegional Blood FlowChronic DiseasePeriodonticsFemalePeriodontal Indexmedicine.symptombusinessChronic gingivitisJournal of Periodontology
researchProduct

Plaque removal efficacy of power and manual toothbrushes: a comparative study

2009

The aim of this study was to compare the plaque removal efficacy of a new oscillating/rotating/pulsating toothbrush [Oral-B® Professional Care® 8500 (PC 8500)] with two manual toothbrushes [Oral-B® CrossAction™ Vitalizer (CAV) and Oral-B® Indicator™ (IND), respectively]. The safety of the PC 8500 was also assessed. The study was a single-use, observer-masked, randomised 3×3 Latin square crossover design balanced for carryover effects. The enrolled subjects (n=66) refrained from brushing for 23–25 h before each clinical examination. Plaque scores were recorded before and after brushing with the allocated toothbrush using the Turesky et al. modification of the Quigley and Hein plaque index. T…

AdultMaleToothbrushingPlaque indexAdolescentPlaque removalPlaque removalDental PlaqueDentistryManual toothbrushPlaque controlStatistics Nonparametriclaw.inventionDental Devices Home CareRandomised crossover single-use studyPower toothbrushYoung AdultElectricitylawSettore MED/28 - Malattie OdontostomatologicheMedicineHumansSingle-Blind MethodManual toothbrushGeneral DentistryAnalysis of VarianceChi-Square DistributionCross-Over StudiesEquipment Safetybusiness.industryDental Plaque IndexMiddle AgedCrossover studyDental Plaque IndexSafety EquipmentPlaque indexFemaleToothbrushSafetybusiness