Search results for "IPM"
showing 10 items of 1361 documents
The Khorana Score in Predicting Venous Thromboembolism for Patients With Metastatic Urothelial Carcinoma and Variant Histology Treated With Chemother…
2017
Background: The Khorana score is a predictive risk model for venous thromboembolism (VTE) in patients with cancer planning to receive chemotherapy. Urothelial carcinoma and variant histologies (UC/VH) were underrepresented in the model. We sought to evaluate whether the Khorana score predicts for VTE in a retrospective multinational data set of patients with metastatic UC/VH. Methods: Patients diagnosed with metastatic UC/VH who received chemotherapy were eligible. Those with incomplete or miscoded data were excluded. Khorana scores were calculated based on the pretreatment data and categorized into high (≥3) or intermediate (1-2) VTE risk. Other patient-, tumor-, and therapy-related factor…
Obesity Triples the Radiation Dose of Stone Protocol Computerized Tomography
2013
Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults.We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation dose…
Differences in kinematic and match-play demands between elite winning and losing wheelchair padel players
2020
We aimed to compare the match-play and kinematic demands of the translation and rotation movements of elite wheelchair padel players as a function of match results. Twenty-two elite male players were video-analysed with a two-dimensional direct linear transformation (DLT) -corrected video system across seven matches of a professional tournament. Distance, turns, changes of direction, linear and angular speed, acceleration and the players’ heart rate (HR) were recorded. Losing couples in wheelchair padel covered greater distances than winners (P <0.001; r = 0.024) and did so at a higher speed (P <0.001; r = 0.06), while making greater efforts by accelerating (P <0.001; ∅ = -0.021), braking (…
Sociodemographic Factors and Clinical Conditions Associated to Hospitalization in Influenza A (H1N1) 2009 Virus Infected Patients in Spain, 2009–2010
2012
The emergence and pandemic spread of a new strain of influenza A (H1N1) virus in 2009 resulted in a serious alarm in clinical and public health services all over the world. One distinguishing feature of this new influenza pandemic was the different profile of hospitalized patients compared to those from traditional seasonal influenza infections. Our goal was to analyze sociodemographic and clinical factors associated to hospitalization following infection by influenza A(H1N1) virus. We report the results of a Spanish nationwide study with laboratory confirmed infection by the new pandemic virus in a case-control design based on hospitalized patients. The main risk factors for hospitalizatio…
Stereoacuity with balanced presbyopic contact lenses.
2010
Our aim was to evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus…
Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.
2011
Background The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens. Methods In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2). In addition, binocular distance vis…
Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.
2014
Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …
Stereoacuity with simultaneous vision multifocal contact lenses.
2010
Our purpose was to evaluate near stereoacuity (SA) with Focus Progressives and PureVision Multifocal simultaneous vision contact lenses. In a cross-over study design, 20 presbyopic subjects were fitted with either the Focus Progressives or PureVision Multifocal lenses. After 1 month, SA was measured with the vectographic Titmus, Random dot stereotests, and the Howard-Dolman apparatus under photopic conditions (85 lux) at 40 cm. Binocular high-contrast visual acuity at distance and near was examined. Subjects were then refitted with the alternative correction and the procedure was repeated. Mean SA with the Focus Progressive was 21 +/- 7 sec arc, 54 +/- 17 sec arc, and 51 +/- 21 sec arc, wit…
Impact of Visual Biofeedback of Trunk Sway Smoothness on Motor Learning during Unipedal Stance.
2020
The assessment of trunk sway smoothness using an accelerometer sensor embedded in a smartphone could be a biomarker for tracking motor learning. This study aimed to determine the reliability of trunk sway smoothness and the effect of visual biofeedback of sway smoothness on motor learning in healthy people during unipedal stance training using an iPhone 5 measurement system. In the first experiment, trunk sway smoothness in the reliability group (n = 11) was assessed on two days, separated by one week. In the second, the biofeedback group (n = 12) and no-biofeedback group (n = 12) were compared during 7 days of unipedal stance test training and one more day of retention (without biofeedback…
Perioperative pupil size in low-energy femtosecond laser-assisted cataract surgery
2020
Purpose To assess potential changes in pupil size during femtosecond laser-assisted cataract surgery (FLACS) using a low-energy laser system. Methods The pupil sizes of eyes undergoing FLACS were measured using the Ziemer LDV Z8 by extracting images from the laser software after each of the following steps: application of suction, lens fragmentation, and capsulotomy. Furthermore, the pupil diameters were measured based on preoperative surgical microscope images and after releasing the suction. Paired t-test and the two one-sided tests (TOST) procedure were used for statistical analyses. The horizontal and vertical pupil diameters were compared in each of the steps with preoperative values.…