Visual Comparison of an Artificial Pupil Contact Lens to Monovision
2012
PURPOSE To assess and compare the effects of contact-lens based artificial pupil design and monovision correction on visual performance. METHODS In a cross-over study design, 22 presbyopic patients (age range 50 to 64 years) were evaluated using artificial pupil contact lens on the non-dominant eye and monovision. After 1 month, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2), in each patient after contact lens fitting. Moreover, BDVA and binocular distance contrast sensitivity were examined under meso…
Visual Performance of a Multifocal Toric Soft Contact Lens
2012
PURPOSE To evaluate the visual performance of the Proclear multifocal toric contact lens (CL; CooperVision, US) for both presbyopia and astigmatism correction. METHODS In this crossover study design, 20 presbyopic subjects with astigmatism were fitted in a random order with either Proclear multifocal toric CL or Proclear toric single vision distance CL (DCL) combined with reading spectacles. After 1 month, high-contrast distance visual acuity, near high-contrast visual acuity, distance contrast sensitivity (CS) under photopic and mesopic conditions without and with glare, near CS, defocus curve, and stereopsis were measured. Subjects were then refitted with the alternative correction, and t…
Comparison of the influence of corneo-scleral and scleral lenses on ocular surface and tear film metrics in a presbyopic population
2018
PURPOSE: To assess and compare the effect of the corneo-scleral lenses (C-ScL) and scleral lenses (ScL) on tear film parameters and central corneal thickness (CCT) in healthy presbyopic subjects. METHODS: Thirty subjects wore two contact lenses (CLs), randomly assigned, of neutral power, but of different diameters, 12.7mm (C-ScL) and 18mm (ScL) and being equal in the others parameters: material (HS100) and centre thickness (0.29mm). At baseline, 20min after insertion and at 8h, the tear meniscus area (TMA) and CCT was measured (with optical coherence tomography) as well as tear osmolarity. RESULTS: TMA revealed statistical differences for both lenses at 20min (p<0.001), and also at 8h (p=0.…
Local and systemic risk factors influencing the long-term success of angular stable alloplastic reconstruction plates of the mandible
2013
Introduction: After ablative surgery of the mandible, angular stable alloplastic reconstruction plates are commonly employed. The aim of the study was a long-term evaluation of local anatomical, as looking at systemic factors influencing specific complications and the failure rate of such plates. Materials and methods: In a retrospective study covering an 11-year period, we reviewed the outcomes of angular stable plates of patients who had a segmental resection of the mandible and subsequent alloplastic reconstruction. Complications and failure rates were assessed and local (anatomical size and localization of resection) as well as systemic risk factors (age, sex, radiation therapy, smoking…
High-speed rotational angioplasty-induced echo contrast in vivo and in vitro optical analysis
1992
High-speed rotational angioplasty is being evaluated as an alternative interventional device for the endovascular treatment of chronic coronary occlusions. It has been postulated that this type of angioplasty device may produce particulate debris or cavitations that induce myocardial ischemia. To determine the clinical presence of myocardial ischemia during rotational angioplasty, echocardiographic monitoring for wall motion abnormalities was performed in 9 patients undergoing rotational atheroablation using the Auth Rotablator for 10-sec intervals at 150,000 and 170,000 rpm. No wall motion abnormalities were detected in 5 patients evaluated with transesophageal echocardiography or in 4 pat…
Usefulness of multislice computed tomography to assess patency of coronary artery stents versus conventional coronary angiography
2008
BACKGROUND: The aim of the present study was to assess the in-stent restenosis and occlusion of coronary artery stents by multislice computed tomography (MSCT) compared with conventional coronary angiography in patients with atypical chest pain and not practicable/non-conclusive stress test. METHODS: Between December 2004 and March 2006, 81 patients were scheduled and of these 72 (65 men, mean age 61 years) with 90 stents underwent MSCT angiography using a 16-slice scanner, Toshiba Aquilion 16, 8-12 months after stent placement. RESULTS: Of the 90 stents, 71 (79%) could be assessed and 19 (21%) were excluded because the image quality at the stent level was incompatible with diagnostic asses…
Results of intracoronary stents for management of coronary dissection after balloon angioplasty.
1991
Dissections after coronary balloon angioplasty are risk factors for acute or subacute vessel closures. Intracoronary stenting was developed to avoid these complications by pressing the intimal and medial flaps against the vessel wall, thus reducing the risk of acute thrombosis. A total of 22 stents were implanted into the coronary arteries of 15 patients with dissections after balloon angioplasty causing angina pectoris or ischemic electrocardiographic changes. Stent delivery was successful in all cases. In 1 patient acute stent thrombosis was documented and treated successfully by thrombolytic therapy. Another patient underwent coronary artery bypass surgery 24 hours later because of persi…
Is It Possible to Create a “Mechanical” Arteriovenous Fistula in Hemodialysis Patients?
2010
Manual suturing still remains the best technique for the creation of vascular anastomoses on uremic patients with excellent results, despite being time consuming, difficult to perform with small vessels, and associated with a significant learning curve. We created a full mechanical arteriovenous fistula on a 65-year-old uremic patient with a new device already used in cardiac bypass surgery. The fistula was created automatically and rapidly, without the need for temporary occlusion of the artery, reducing the risk of blood clotting. We believe that mechanical devices may be useful to produce precise and fast anastomoses requiring minimal training for the surgeon.
Prospective, randomized, single-center trial comparing 3 different 10F plastic stents in malignant mid and distal bile duct strictures.
2003
Abstract Background: The aim of this study was to determine whether patency rates differ with respect to the material, design, and surface texture of 3 different plastic stents. Methods: A total of 120 patients (median age 70.5 years; interquartile range 62-78 years) with malignant mid or distal bile duct strictures, seen between March 1996 and May 1999, were prospectively randomized to receive a 10F polyurethane stent, a Teflon Tannenbaum stent, or a hydrophilic hydromer-coated polyurethane stent. The primary study outcome measure was the interval between stent insertion and the first episode of clogging (or the presence of jaundice at death without stent exchange). All 3 types of stent we…
[Penile Flexiflate® Surgitek prosthesis explant and simultaneous three-component hydraulic Titan® Alpha 1 prosthesis implantation, with double incisi…
2010
Introduction and Objectives We treated a 45 years old patient, suffering from diabetes mellitus since childhood, with retinal, neurovascular and kidney complications. In 1988, for erectile dysfunction (ED) resistant to medical injective treatment, the patient underwent ligation of the dorsal vein of the penis without any result. In 1989 a Flexiflate® hydraulic prosthesis was implanted with resolution of ED. In 2005 the patient underwent simultaneous kidney and pancreas transplant with a trans-laparotomic approach for end stage renal disease and diabetes mellitus. In 2009, because of the Flexiflate® Surgitek malfunction, the patient underwent explantation of the Flexiflate® prosthesis and si…