Search results for "IPM"
showing 10 items of 1361 documents
Ischemic stroke risk during long-term follow up in patients with successful catheter ablation for atrial fibrillation in Korea
2018
The interruption of oral anticoagulation therapy (OAC) after CA of atrial fibrillation (AF) is controversial. The purpose of this study was to evaluate the relationship between successful long-term outcomes of catheter resection and SR maintenance and ischemic stroke risk in Korea. We studied 1,548 consecutive patients who were followed up for more than 2 years after CA of AF. We investigated the incidence of ischemic stroke during long-term follow-up. Compared to the AF recurrence group (n = 619), the sinus rhythm (SR) maintenance group (n = 929) had more paroxysmal AF (74.6% versus 44.4%, p<0.001), smaller LA size (39.9±5.7mm versus 42.3±6.0mm, p<0.001), and younger age (54.2±10.9 years v…
Neuromodulation of the superior hypogastric plexus: a new option to treat bladder atonia secondary to radical pelvic surgery?
2009
Abstract Background The aim of this study is to report on the impact of neuromodulation to the superior hypogastric plexus in patients with bladder atonia secondary to pelvic surgery. Methods In 4 consecutive patients with bladder atonia secondary to pelvic surgery, we performed a laparoscopic implantation of a neurostimulator—LION procedure—to the entire superior hypogastric plexus. Results Of the 4 reported patients, 3 are able to partially void or empty their bladder. Conclusions If the presented results could be obtained in further patients and maintained in long-term follow-up, the LION procedure to the superior hypogastric plexus could change the management of bladder function in pati…
Three dimensional reconstruction to visualize atrial fibrillation activation patterns on curved atrial geometry
2021
BackgroundThe rotational activation created by spiral waves may be a mechanism for atrial fibrillation (AF), yet it is unclear how activation patterns obtained from endocardial baskets are influenced by the 3D geometric curvature of the atrium or ‘unfolding’ into 2D maps. We develop algorithms that can visualize spiral waves and their tip locations on curved atrial geometries. We use these algorithms to quantify differences in AF maps and spiral tip locations between 3D basket reconstructions, projection onto 3D anatomical shells and unfolded 2D surfaces.MethodsWe tested our algorithms in N = 20 patients in whom AF was recorded from 64-pole baskets (Abbott, CA). Phase maps were generated by…
Locking plates for corrective osteotomy of malunited dorsally tilted distal radial fractures: a biomechanical study.
2005
The purpose of the study was to compare the biomechanical properties of five different palmar fixation plate designs in a distal radius osteotomy cadaver model. A 1 cm metaphyseal osteotomy gap was made to simulate a corrective osteotomy and the osteotomy plated. Axial load was applied to the distal end of each construct by a material testing machine under control of a motion analysis video system. The specimens were arranged into five implant groups of eight specimens each. No test group developed deformity and movement of the fracture gap greater than 2 mm with a load of 100 N. Increasing the load to 250 N revealed statistically significant differences in stiffness and failure load betwe…
Number and Locations of Screw Fixation for Volar Fixed-Angle Plating of Distal Radius Fractures: Biomechanical Study
2010
Purpose To compare the biomechanical properties of different numbers and locations of screws in a multidirectional volar fixed-angle plate in a distal radius osteotomy cadaver model. Methods We created an extra-articular fracture in 16 pairs of fresh-frozen human cadaver radiuses. The 32 specimens were randomized into 4 groups. All fractures were fixated with a multidirectional volar fixed-angle plate. We tested 4 different screw-placement options in the distal fragment. The distal fragment was fixed with 4 locking screws in the distal row of the plate in group a, and with 4 locking screws alternately in the distal and proximal rows in group b. In group c, 3 locking screws were used in the …
Is there a role for percutaneous pelvic and acetabular reconstruction?
2007
The primary goal in the treatment of pelvic fractures is the restoration of haemodynamic stability. The secondary goal is the reconstruction of stability and symmetry of the pelvic ring. Percutaneous reconstruction can only be accepted if these goals are met. The type of definitive surgery is dependent of the degree of instability of the anterior and posterior pelvic ring. Retrograde transpubic screw fixation of pubic rami fractures is a good alternative to external fixation or plate and screw osteosynthesis. The technique of screw placement and image intensifier control is explained. Internal fixation of pure sacroiliac dislocations, fracture-dislocations of the sacroiliac joint and sacral…
Secondary Osseous Integration of Cementless Unicompartmental Knee Arthroplasty After Internal Fixation of a Felix Type IIIB Fracture
2021
Case A 76-year-old man presented with periprosthetic tibial plateau fracture (TPF), with a completely loosened tibial component 3 weeks after cementless unicompartmental knee arthroplasty (UKA). Internal fixation by buttress plating was performed, and the tibial component was retained and left in situ primarily as a spacer. Revision was planned after fracture consolidation, but at 3 months, the patient was able to walk without support, without pain, and with full range of motion. At 1 year, he is free of complaints. The initial loosened tibial component reintegrated. Conclusion Internal fixation combined with preserving the loosened tibial component may be a treatment option for TPF involvi…
Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements
2008
PURPOSE: To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. METHODS: Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens made of the same material (Optima 38, Bausch & Lomb). Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred. RESULTS: The subjects' mean straylight values were 0.90 +/- 0.09 at baseline and 0.95 +/- …
Changes in performance and poling kinetics during cross-country sprint skiing competition using the double-poling technique
2013
In this study, changes in skiing performance and poling kinetics during a simulated cross-country sprint skiing competition were investigated. Twelve elite male cross-country skiers performed simulated sprint competition (4 x 1,150 m heat with 20 min recovery between the heats) using the double-poling technique. Vertical and horizontal pole forces and cycle characteristics were measured using a force plate system (20-m long) during the starting spurt, racing speed, and finishing spurt of each heat. Moreover, heat and 20-m phase velocities were determined. Vertical and horizontal pole impulses as well as mean cycle length were calculated. The velocities of heats decreased by 2.7 +/- 1.7% (p …
Sprint Time Differences Between Single- and Dual-Beam Timing Systems
2014
Valid and reliable measures of sprint times are necessary to detect genuine changes in sprinting performance. It is currently difficult for practitioners to assess which timing system meets this demand within the constraints of a proper cost-benefit analysis. The purpose of this investigation was to quantify sprint time differences between single-beam (SB) and dual-beam (DB) timing systems. Single-beam and DB photocells were placed at 0, 20, and 40 m to compare 0-20 and 20-40 m sprint times. To control for the influence of swinging limbs between devices, 2 recreationally active participants cycled as fast as possible through the track 25 times with a 160-cm tube (18 cm diameter) vertically …