Search results for "IPM"
showing 10 items of 1361 documents
Multi-laboratory experiment PME11 for the standardization of phosphoproteome analysis
2022
6 p.-2 fig.-2 tab.
A New Configuration for Helmet Continuous Positive Airway Pressure Allowing Tidal Volume Monitoring
2020
We performed a bench and human study to test the hypothesis that a ventilator can accurately estimate Vt when a helmet is used in CPAP mode in a single limb configuration with an intentional leak port placed at the helmet expiratory port. We have recently demonstrated the effectiveness of this setup in bilevel mode
Secondary Carina and Lobar Bronchi Stenting in Patients with Advanced Lung Cancer: Is It Worth the Effort? A Clinical Experience
2020
Background: The lobar airway stenting remains an endoscopic procedure not well standardized in patients with locally advanced lung cancer disease. The goal of this study was to evaluate technical feasibility, clinical outcome, and complications of different stents in patients with malignant lesions involving lobar bronchi, primary and secondary carina. Methods: Between November 2008 and October 2013, we retrospectively analyzed 146 patients with benign and malignant tracheobronchial stenosis who underwent airway stent insertion below main carina and main bronchi. Results: In all, 170 airway stenting procedures were performed on 146 patients. In all, 51 of them with malignant peripheral airw…
Evaluation of VTE-BLEED for predicting intracranial or fatal bleeding in stable anticoagulated patients with venous thromboembolism.
2018
VTE-BLEED predicts fatal and/or intracranial bleeding in patients with venous thromboembolism treated with long-term anticoagulants http://ow.ly/3hqg30iXK5a
Low-energy epicardial pacing in children: the benefit of autocapture.
1999
Abstract Background . Permanent cardiac pacing in children results commonly in augmented energy consumption because of the high pacing rates and the ample stimulation safety margin applied in children. Cardiovascular anatomy and limited venous access sometimes preclude the otherwise preferred endocardial approach. In this multicenter patient series, we studied the feasibility, safety, and energy saving obtained by a combination of steroid-eluting epicardial leads with autocapture devices capable of ongoing adjustment of the stimulation output to the prevailing threshold. Methods . Autocapture devices (Pacesetter Microny SR+ and Regency SR+; Pacesetter, Solna, Sweden) and steroid-eluting epi…
Intraoperative cryoablation of atrial fibrillation with the old-fashioned cryode tips: a simple, effective, and inexpensive method.
2006
Nowadays atrial fibrillation is usually treated simultaneously with cardiac procedures, and new cryo-systems have been developed for performing easier and faster intraoperative ablation. However, the old cryode designs can still be useful in surgical practice and represent a more cost-effective method. In this article we present a technique using old-fashioned cryodes for intraoperative treatment of atrial fibrillation and comment on its advantages and limitations.
Material and Technology: Back to the Future for the Choice of Interface for Non-Invasive Ventilation – A Concise Review
2020
Non-invasive ventilation (NIV) has dramatically changed the treatment of both acute and chronic respiratory failure in the last 2 decades. The success of NIV is correlated to the application of the “best ingredients” of a patient’s “tailored recipe,” including the appropriate choice of the selected candidate, the ventilator setting, the interface, the expertise of the team, and the education of the caregiver. The choice of the interface is crucial for the success of NIV. Type (oral, nasal, nasal pillows, oronasal, hybrid mask, helmet), size, design, material and headgears may affect the patient’s comfort with respect to many aspects, such as air leaks, claustrophobia, skin erythema, eye irr…
The da Vinci Xi Robotic Four-Arm Approach for Robotic-Assisted Minimally Invasive Esophagectomy
2018
AbstractRobotic surgery is gaining importance in complex thoracoscopic surgery, such as robotic-assisted minimally invasive esophagectomy (RAMIE). The RAMIE procedure was designed using the first generation of the robotic system. The latest da Vinci Xi system has substantially increased the dexterity, especially designed for multiquadrant surgery. The original three-arm RAMIE approach was modified including the robotic four-arm use for the thoracoscopic and laparoscopic part of the operation. This extended approach (four-arm RAMIE approach) provides more flexibility and raises the independence of the surgeon.
Near-normal aerobic capacity in long-term survivors after lung transplantation
2021
The clinical course of lung transplantation (LT) is diverse: some patients present chronic lung allograft dysfunction (CLAD) and progressive decline in pulmonary function, but others maintain normal spirometric values and active lives. Objectives The aim of this study was to elucidate whether long-term LT survivors with normal spirometry achieve normal exercise capacity, and to identify predictive factors of exercise capacity. Methods This was a cross-sectional multicentre study, where bilateral LT recipients who survived at least 10 years after LT, with normal spirometry, no diagnosis of CLAD and modified Medical Research Council dyspnoea degree ≤2 underwent cardiopulmonary exercise testin…
Ventilator Settings to Avoid Nuisance Alarms During Mouthpiece Ventilation
2016
BACKGROUND: A recent study found that activation of disconnection and low-pressure alarms is common during mouthpiece ventilation and may represent a major limitation to its use. The aim of this bench study was: (1) to investigate the technical aspects that can influence the setting of the ventilator during mouthpiece ventilation and (2) to provide a practical setting strategy to avoid the alarm activation. METHODS: Eight life-support ventilators able to deliver volume controlled ventilation were tested in a bench study using a single-limb non-vented circuit configuration connected to a standard mouthpiece. Disconnection and apnea alarm were turned off or set at the least sensitive setting.…