Search results for "Ileu"

showing 10 items of 244 documents

A1 receptor-mediated modulatory effects of adenosine on the contractility in mouse ileum: characterization of signal transduction pathway

2008

AdenosineMouse ileumMechanical activityAdenosine A1 receptorSettore BIO/09 - FisiologiaP1 purinoceptorPotassium channels
researchProduct

"A1 receptors mediate the inhibitory effects of adenosine on the contractility in mouse ileum.”

2008

AdenosineMouse ileumMechanical activitySettore BIO/09 - FisiologiaP1 purinoceptor
researchProduct

Goldmann Tonometry After Hyperopic Laser In Situ Keratomileusis

2004

PURPOSE To identify differences in applanation tonometry between retreated and nonretreated eyes (primary LASIK eyes) 6 months after hyperopic laser in situ keratomileusis. METHODS In a prospective study 100 eyes (100 patients) underwent conventional hyperopic laser in situ keratomileusis under a 160-microm flap. Central Goldmann applanation tonometry was determined before and 6 months after surgery in 78 (78%) primary LASIK eyes and before surgery and 6 months after the retreatment date in 22 (22%) retreated eyes. RESULTS Preoperative mean tonometry was 14.96 +/- 1.96 mm Hg and 15.30 +/- 1.95 mm Hg in primary LASIK and retreated eyes, respectively. Six months after surgery it was 12.99 +/-…

AdultApplanation tonometrymedicine.medical_specialtyIntraocular pressureTime Factorsgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SitueducationKeratomileusisGoldmann applanation tonometryTonometry OcularmedicineHumansPostoperative PeriodProspective StudiesIntraocular Pressurebusiness.industrySignificant differenceLASIKhumanitieseye diseasesSurgeryGoldmann tonometryOphthalmologyHyperopiaTreatment OutcomeRetreatmentsense organsbusinessCornea
researchProduct

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses

2011

PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…

AdultCorneal Wavefront AberrationDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityArtificial Lens Implant MigrationRefraction OcularYoung AdultPostoperative ComplicationsHumansMedicineContrast (vision)media_commonLenses Intraocularbusiness.industryLASIKeye diseasesOphthalmologySpherical aberrationHyperopiaTilt (optics)Intraocular lensesDecreased Visual AcuityOftalmologíaOptometryLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK

2018

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…

AdultCorneal surgery laserIntraocular pressuremedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPaquimetria corneanagenetic structuresIntraocular pressuremedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityLentes de contatoKeratomileusisCorneal endothelial cell losslaw.invention03 medical and health sciencesCorneal pachymetry0302 clinical medicinePerda de células endoteliais da córneaPressão intraocularlcsh:OphthalmologylawOphthalmologyMyopiaHumansMedicineContact lensesCorneal pachymetryCirurgia da córnea a laserRetrospective Studiesmedicine.diagnostic_testbusiness.industryCorneal TopographyLASIKGeneral MedicineContact Lenses HydrophilicCorneal topographyeye diseasesLens (optics)Contact lensOphthalmologylcsh:RE1-994030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

Randomized placebo-controlled trial comparing desloratadine and montelukast in monotherapy and desloratadine plus montelukast in combined therapy for…

2004

BACKGROUND: H 1 -receptor antagonists are considered to be particularly effective in reducing pruritus, and they are therefore recommended as first-line treatment in patients with chronic idiopathic urticaria (CIU). Recently, antileukotriene receptors have been used in patients with CIU, either administered as monotherapy or combined with H 1 -receptor antagonists. OBJECTIVE: We compared the clinical efficacy of 5 mg of desloratadine administered once daily either as monotherapy or combined with a leukotriene antagonist, 10 mg of montelukast daily, and 10 mg of montelukast administered daily as monotherapy for the treatment of patients affected by CIU with placebo. METHODS: One hundred sixt…

AdultCyclopropanesMalemedicine.medical_specialtyHistamine H1 Antagonists Non-SedatingSettore MED/09 - Medicina InternaAdolescentUrticariamedicine.medical_treatmentImmunologyPlacebo-controlled studyRandomized placebo-controlled trial; desloratadine; montelukast; chronic idiopathic urticariaAcetatesSulfidesPlaceboGastroenterologylaw.inventionchemistry.chemical_compoundRandomized controlled trialDouble-Blind MethodlawInternal medicinemedicineImmunology and AllergyHumansMontelukastAgedDesloratadineLeukotriene E4Leukotriene receptorbusiness.industrydesloratadineRandomized placebo-controlled trialLoratadineMiddle AgedAntileukotrieneTreatment OutcomechemistryAnesthesiachronic idiopathic urticariaChronic DiseasemontelukastQuinolinesLeukotriene AntagonistsFemalebusinessmedicine.drug
researchProduct

Diagnosis and grading of acute graft-versus-host disease in endoscopic biopsy series throughout the upper and lower intestine in patients after allog…

2019

Intestinal graft-versus-host disease (GvHD) is a potentially life-threatening condition after allogenic hematological stem cell transplantation (alloHSCT). Although efforts have been made to determine the best sites for endoscopic biopsies, an approach involving all accessible anatomical regions is lacking. We investigated 22 complete biopsy series, each comprising biopsies from 10 different sites of the upper and lower intestine from 21 patients. The majority of biopsies investigated revealed histological signs of acute GvHD. The highest incidence and most advanced grades of acute GvHD were found in the right colon and terminal ileum. We detected significant correlations between crypt or g…

AdultMaleCancer Researchmedicine.medical_specialtymedicine.medical_treatmentBiopsyGraft vs Host DiseaseIleumApoptosisHematopoietic stem cell transplantationDiseaseGastroenterologySeverity of Illness Index03 medical and health sciences0302 clinical medicineInternal medicineMedicineHumansTransplantation HomologousGrading (tumors)Agedbusiness.industryStomachHematopoietic Stem Cell TransplantationEndoscopyHematologyMiddle Agedmedicine.diseaseTransplantationPatient Outcome Assessmentsurgical procedures operativemedicine.anatomical_structureGraft-versus-host diseaseOncology030220 oncology & carcinogenesisHematologic NeoplasmsFemaleStem cellbusinessImmunosuppressive Agents030215 immunologyLeukemialymphoma
researchProduct

Intraocular pressure after excimer laser myopic refractive surgery

2001

The aim of this study was to determine whether intraocular pressure (IOP), as measured by Goldmann applanation or non-contact tonometry, shows systematic changes in patients who have undergone photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK). IOP was measured by central Goldmann and non-contact tonometry in 54 patients pre and post-PRK, and in 43 patients pre- and post-LASIK. An interval of 12 months was allowed after surgery. Patients were selected to have one of four specific initial values of refractive error (-2.5, -5.0, -7.5 and -10.0 D). Fellow unoperated eyes were used as controls. A paired Student's t-test and a one-way ANOVA test were used for statistical a…

AdultMaleIntraocular pressuremedicine.medical_specialtyRefractive errorgenetic structuresmedicine.medical_treatmentEye diseaseKeratomileusis Laser In SituContext (language use)KeratomileusisPhotorefractive KeratectomySensitivity and SpecificityTonometry OcularRefractive surgeryOphthalmologyMyopiamedicineHumansIntraocular PressureAnalysis of Variancebusiness.industryLASIKmedicine.diseaseeye diseasesSensory SystemsPhotorefractive keratectomySurgeryOphthalmologyFemaleLasers Excimersense organsbusinessOptometryOphthalmic and Physiological Optics
researchProduct

Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery

2013

To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…

AdultMaleOptics and PhotonicsPhakic Intraocular Lensesmedicine.medical_specialtyCorneal Wavefront AberrationAdolescentgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisPhakic intraocular lensContrast SensitivityYoung AdultLens Implantation IntraocularAberrometryMyopiamedicineHumansIn patientPostoperative PeriodImplantable collamer lensbusiness.industryAberrometryLASIKGeneral Medicineeye diseasesSurgeryOphthalmologySpherical aberrationOptometryFemaleLasers ExcimerbusinessEuropean Journal of Ophthalmology
researchProduct