Search results for "Illumination"
showing 10 items of 57 documents
Vertical Root Fracture initiation in curved roots after root canal preparation : a dentinal micro-crack analysis with LED transillumination
2017
Background One of the causative factors of root defects is the increased friction produced by rotary instrumentation. A high canal curvature may increase stress, making the tooth more susceptible to dentinal cracks. The purpose of this study was to evaluate dentinal micro-crack formation with the ProTaper NEXT and ProTaper Universal systems using LED transillumination, and to analyze the micro-crack generated at the point of maximum canal curvature. Material and Methods 60 human mandibular premolars with curvatures between 30–49° and radii between 2–4 mm were used. The root canals were instrumented using the Protaper Universal® and Protaper NEXT® systems, with the aid of the Proglider® syst…
Tunable-frequency three-dimensional structured illumination microscopy with reduced data-acquisition
2018
The performance of a tunable three-dimensional (3D) structured illumination microscope (SIM) system and its ability to provide simultaneously super-resolution (SR) and optical-sectioning (OS) capabilities are investigated. Numerical results show that the performance of our 3D-SIM system is comparable with the one provided by a three-wave interference SIM, while requiring 40% fewer images for the reconstruction and providing frequency tunability in a cost-effective implementation. The performance of the system has been validated experimentally with images from test samples, which were also imaged with a commercial SIM based on incoherent-grid projection for comparison. Restored images from d…
4D (x-y-z-t) imaging of thick biological samples by means of Two-Photon inverted Selective Plane Illumination Microscopy (2PE-iSPIM)
2015
AbstractIn the last decade light sheet fluorescence microscopy techniques, such as selective plane illumination microscopy (SPIM), has become a well established method for developmental biology. However, conventional SPIM architectures hardly permit imaging of certain tissues since the common sample mounting procedure, based on gel embedding, could interfere with the sample morphology. In this work we propose an inverted selective plane microscopy system (iSPIM), based on non-linear excitation, suitable for 3D tissue imaging. First, the iSPIM architecture provides flexibility on the sample mounting, getting rid of the gel-based mounting typical of conventional SPIM, permitting 3D imaging of…
Enhanced field-of-view integral imaging display using multi-Köhler illumination.
2014
A common drawback in 3D integral imaging displays is the appearance of pseudoimages beyond the viewing angle. These pseudoimages appear when the light rays coming from each elemental image are not passing through the corresponding microlens, and a set of barriers must be used to avoid this flipping effect. We present a pure optical arrangement based on Köhler illumination to generate these barriers thus avoiding the pseudoimages. The proposed system does not use additional lenses to project the elemental images, so no optical aberrations are introduced. As an added benefit, Köhler illumination provides a higher contrast 3D display. This work was supported in part by the Plan Nacional I + D …
Live imaging of developmental processes in a living meristem of Davidia involucrata (Nyssaceae)
2014
Morphogenesis in plants is usually reconstructed by scanning electron microscopy and histology of meristematic structures. These techniques are destructive and require many samples to obtain a consecutive series of states. Unfortunately, using this methodology the absolute timing of growth and complete relative initiation of organs remain obscure. To overcome this limitation, an in vivo observational method based on Epi-Illumination Light Microscopy (ELM) was developed and tested with a male inflorescence meristem (floral unit) of the handkerchief tree Davidia involucrata Baill. (Nyssaceae). We asked whether the most basal flowers of this floral unit arise in a basipetal sequence or, altern…
Lattice Corneal Dystrophy Type 1
2014
PURPOSE To evaluate the question whether lattice corneal dystrophy type 1 (LCD1) is of epithelial or stromal origin. METHODS The landmark of advanced LCD1 shows central superficial haze and paracentral stromal lattice lines. In 16 eyes of 8 affected individuals of 2 families, a penetrating keratoplasty was performed. The follow-up was 8 to 16 years after penetrating keratoplasty. Slit-lamp documentation of the patients was evaluated in direct and indirect illumination with dilated pupil to assess the horizontal and vertical pattern of new deposits on the corneal graft. Three affected patients of 2 families are demonstrated in detail. A DNA analysis was performed. RESULTS Gene identification…
Illumination Correction on MR Images
2006
Objective. An important artifact corrupting Magnetic Resonance Images is the rf inhomogeneity, also called bias artifact. This anomaly produces an abnormal illumination fluctuation on the image, due to variations of the device magnetic field. This artifact is particularly strong on images acquired with a device specialized on upper and lower limbs due to their coil configuration. A method based on homomorphic filtering aimed to suppress this artifact was proposed by Guillemaud. This filter has two faults: it doesnt provide an indication about the cutoff frequency (cf) and introduces another illumination artifact on the edges of the foreground. This work is an improvement to this method because i…
Die Transilluminationstechnik
1996
The technique of light-guided intubation is based on the principle that a source of light brought into the trachea results in clearly visible and defined transcutaneous illumination, while no illumination can be observed with the light source in the oesophagus (Fig. 1-7). The Trachlight is a reintroduced instrument for this alternative intubation technique. The essential developments are: a length-adjustable stylet with a removable internal metal wire, a brighter light source, a stable handle with tight fixation of the endotracheal tube, and a time-dependent warning device to avoid extended intubations. One hundred twenty patients (Mallampati I. ASA I-III) were included in the study (conven…
A new selective fluorogenic probe for trivalent cations.
2012
[EN] A new selective chromo-fluorogenic probe for Fe 3+, Cr 3+ and Al 3+ is reported. Detection limits are in the ¿M range and the fluorogenic sensing ability could be observed by the naked eye when illuminated with UV-light. No response is observed with divalent cations. © 2012 The Royal Society of Chemistry.
Express RGB mapping of three to five skin chromophores
2017
Skin melanin, oxy- and deoxy-hemoglobin were snapshot-mapped under simultaneous 448-532-659 nm laser illumination by a smartphone RGB camera. Experimental prototypes for double-snapshot RGB mapping of four (melanin, bilirubin, oxy- and deoxy-hemoglobin) and five (melanin, bilirubin, lipids, oxy- and deoxy-hemoglobin) skin chromophores with reduced laser speckle artefacts have been developed and tested. A set of 405-448-532-659 nm lasers were used for four chromophores mapping, and a set of 405-448-532-659-842 nm lasers for five chromophores mapping. Clinical tests confirmed functionality of the developed devices.