Search results for "Image Enhancement"

showing 10 items of 215 documents

Controlling diffusion of 3He by buffer gases: a structural contrast agent in lung MRI.

2006

Purpose: To study the influence of admixing inert buffer gases to laser-polarized 3 He in terms of resulting diffusion coefficients and the consequences for image contrast and resolution. Materials and Methods: The diffusion coefficient of 3 He was altered by admixing buffer gases of various molecular weights ( 4 He, N2, and SF6). The influence of the pulse sequence and the diffusion coefficient on the appearance of MRI of (laserpolarized) gases was analyzed by comparison of basic theoretical concepts with demonstrative experiments. Results: Excellent agreement between theoretical description and observed signal in simple gradient echoes was observed. A maximum signal gain can be predicted …

InertMaterials sciencePhantoms ImagingDiffusionPhysics::Medical PhysicsBuffer gasResolution (electron density)Contrast MediaReproducibility of ResultsPulse sequenceImage EnhancementSignalMolecular physicsHeliumSensitivity and SpecificityDiffusion Magnetic Resonance ImagingIsotopesRestricted DiffusionEffective diffusion coefficientHumansRadiology Nuclear Medicine and imagingGasesLungJournal of magnetic resonance imaging : JMRI
researchProduct

3D integral imaging display by smart pseudoscopic-to-orthoscopic conversion (SPOC).

2010

Previously, we reported a digital technique for formation of real, non-distorted, orthoscopic integral images by direct pickup. However the technique was constrained to the case of symmetric image capture and display systems. Here, we report a more general algorithm which allows the pseudoscopic to orthoscopic transformation with full control over the display parameters so that one can generate a set of synthetic elemental images that suits the characteristics of the Integral-Imaging monitor and permits control over the depth and size of the reconstructed 3D scene.

Integral imagingbusiness.industryComputer scienceAperture synthesisComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONReproducibility of ResultsImage EnhancementSensitivity and SpecificityAtomic and Molecular Physics and OpticsTransformation (function)OpticsImaging Three-DimensionalImage Interpretation Computer-AssistedComputer visionArtificial intelligenceImage sensorbusinessImage resolutionAlgorithmsOptics express
researchProduct

Dynamic laser speckle analyzed considering inhomogeneities in the biological sample

2017

Dynamic laser speckle phenomenon allows a contactless and nondestructive way to monitor biological changes that are quantified by second-order statistics applied in the images in time using a secondary matrix known as time history of the speckle pattern (THSP). To avoid being time consuming, the traditional way to build the THSP restricts the data to a line or column. Our hypothesis is that the spatial restriction of the information could compromise the results, particularly when undesirable and unexpected optical inhomogeneities occur, such as in cell culture media. It tested a spatial random approach to collect the points to form a THSP. Cells in a culture medium and in drying paint, repr…

LightSurface PropertiesComputer scienceGaussianNormal DistributionBiomedical EngineeringCoffeaSample (statistics)01 natural sciencesPattern Recognition Automated010309 opticsBiomaterialsMicesymbols.namesakeSpeckle patternOpticsPosition (vector)NeoplasmsElectronic speckle pattern interferometry0103 physical sciencesImage Processing Computer-AssistedAnimalsbusiness.industryLasersQuantization (signal processing)Speckle noise04 agricultural and veterinary sciencesImage EnhancementAtomic and Molecular Physics and OpticsCulture MediaElectronic Optical and Magnetic MaterialsRAW 264.7 CellsSeedsLine (geometry)Cats040103 agronomy & agriculturesymbols0401 agriculture forestry and fisheriesbusinessBiological systemAlgorithmsJournal of Biomedical Optics
researchProduct

Contrast ultrasound LI-RADS LR-5 identifies hepatocellular carcinoma in cirrhosis in a multicenter restropective study of 1,006 nodules

2018

Background & Aims The use of contrast enhanced ultrasound (CEUS) for the diagnosis of hepatocellular carcinoma (HCC) in cirrhosis was questioned because of the risk of a false positive diagnosis in cases of cholangiocarcinoma. The American College of Radiology has recently released a scheme (CEUS Liver Imaging Reporting and Data System [LI-RADS®]) to classify lesions at risk of HCC investigated by CEUS. The aim of the present study was to validate this LI-RADS scheme for the diagnosis of HCC. Methods A total of 1,006 nodules from 848 patients with chronic liver disease at risk of HCC were collected in five Italian centers and retrospectively analyzed. Nodules were classified as LR-5, (HCC) …

Liver CirrhosisMaleCirrhosisContrast enhanced ultrasoundContrast MediaChronic liver diseaseGastroenterology030218 nuclear medicine & medical imagingCholangiocarcinoma0302 clinical medicineDiagnosisMedicineTomographyWashoutUltrasonographyUltrasoundLiver NeoplasmsMiddle AgedMagnetic Resonance ImagingX-Ray ComputedLiverHepatocellular carcinoma030211 gastroenterology & hepatologyFemaleRadiologymedicine.symptomAlgorithmsContrast-enhanced ultrasoundAdultmedicine.medical_specialtyCarcinoma HepatocellularDiagnosis Differential03 medical and health sciencesInternal medicineHumansDiagnostic ErrorsneoplasmsAgedLiver Imaging Reporting And Data System (LI-RADS)Hepatologybusiness.industryCarcinomaSettore MED/09 - MEDICINA INTERNAReproducibility of ResultsHepatocellularRetrospective cohort studyHistologyNodule (medicine)medicine.diseaseImage Enhancementdigestive system diseasesArterial hyperenhancementDifferentialbusinessTomography X-Ray Computed
researchProduct

MRI of the pulmonary parenchyma.

1999

Imaging of the pulmonary parenchyma represents a unique challenge for MRI. Limited signal is caused by low proton density, susceptibility artifacts, and physiological motion (cardiac pulsation, respiration). Recently, further improvements in MRI techniques have widened the potential for investigations of pulmonary parenchymal disease. These include very short echo times, ultrafast turbo-spin-echo acquisitions, projection reconstruction technique, breathhold imaging, ECG triggering, contrast agents (perfusion imaging, aerosols), sodium imaging, hyperpolarized noble gas imaging, and oxygen enhancement. By using widely available techniques, MRI is helpful in the assessment of (a) acute alveoli…

Lung DiseasesChronic bronchitismedicine.medical_specialtyPulmonary FibrosisContrast MediaAtelectasisPerfusion scanningPulmonary EdemaSensitivity and SpecificityDiagnosis DifferentialMedicineHumansRadiology Nuclear Medicine and imagingLungNeuroradiologyBronchiectasisLungbusiness.industryGeneral MedicinePneumoniamedicine.diseasePulmonary edemaImage EnhancementMagnetic Resonance ImagingPneumoniamedicine.anatomical_structureInjections IntravenousRadiologybusinessPulmonary EmbolismEuropean radiology
researchProduct

Prevalence of coronary artery intramyocardial course in a large population of clinical patients detected by multislice computed tomography coronary a…

2008

Background: Intramyocardial course, an inborn coronary anomaly, is defined as a segment of a major epicardial coronary artery that runs intramurally through the myocardium; in particular, we distinguish myocardial bridging, in which the vessel returns to an epicardial position after the muscle bridge, and intramyocardial course, which is described as a vessel running and ending in the myocardium. Purpose: To evaluate the prevalence of myocardial bridging and intramyocardial course of coronary arteries as defined by multidetector computed tomography (MDCT) angiography. Material and Methods: The study population consisted of 242 consecutive patients (211 men, 31 women; mean age 59±6 years) w…

MaleChest Painmedicine.medical_specialtyCoronary Vessel AnomaliesContrast MediaCoronary AngiographyChest painCoronary artery diseaseElectrocardiographyImaging Three-DimensionalInternal medicineHeart ratePrevalencemedicineHumansRadiology Nuclear Medicine and imagingMultisliceObserver VariationRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryGeneral MedicineMiddle AgedAtenololmedicine.diseaseIopamidolRadiographic Image EnhancementCoronary arteriesmedicine.anatomical_structurecoronary arteryCTCardiologyFemaleRadiologymedicine.symptomTomography X-Ray ComputedbusinessElectrocardiographymedicine.drugArtery
researchProduct

EEG-related Functional MRI in Benign Childhood Epilepsy with Centrotemporal Spikes

2003

The localization of epileptic foci is an important issue in children with extratemporal epilepsies. However, the value of noninvasive methods such as the EEG-assisted functional magnetic resonance imaging (fMRI) has not been sufficiently investigated in children. As a model of extratemporal epilepsies, we studied 7 patients aged 5 to 12 (median 10) years with benign childhood epilepsy and centrotemporal (rolandic) spikes. Interictal spikes were recorded during the fMRI acquisition on a MR-compatible battery-powered digital EEG system with 16 channels. The fMRI sequences were correlated off-line with the EEG spikes and analyzed with the software Statistical Parametrical Mapping SPM99. The fM…

MaleChildhood epilepsyElectroencephalographyEEG-fMRICentral nervous system diseaseEpilepsyOxygen ConsumptionImage Processing Computer-AssistedmedicineHumansIctalChildEvoked PotentialsMathematical ComputingBrain Mappingmedicine.diagnostic_testElectroencephalographySignal Processing Computer-AssistedImage Enhancementmedicine.diseaseEpilepsy RolandicMagnetic Resonance ImagingTemporal LobeFunctional imagingNeurologyChild PreschoolFemaleNeurology (clinical)Functional magnetic resonance imagingPsychologyNeuroscienceEpilepsia
researchProduct

A supervised learning framework of statistical shape and probability priors for automatic prostate segmentation in ultrasound images

2013

Prostate segmentation aids in prostate volume estimation, multi-modal image registration, and to create patient specific anatomical models for surgical planning and image guided biopsies. However, manual segmentation is time consuming and suffers from inter-and intra-observer variabilities. Low contrast images of trans rectal ultrasound and presence of imaging artifacts like speckle, micro-calcifications, and shadow regions hinder computer aided automatic or semi-automatic prostate segmentation. In this paper, we propose a prostate segmentation approach based on building multiple mean parametric models derived from principal component analysis of shape and posterior probabilities in a multi…

MaleComputer sciencePosterior probabilityScale-space segmentationImage registrationHealth InformaticsSensitivity and SpecificityPattern Recognition AutomatedArtificial IntelligenceImage Interpretation Computer-AssistedHumansRadiology Nuclear Medicine and imagingComputer visionSegmentationUltrasonographyRadiological and Ultrasound TechnologySegmentation-based object categorizationbusiness.industryProstateProstatic NeoplasmsReproducibility of ResultsPattern recognitionImage segmentationImage EnhancementComputer Graphics and Computer-Aided DesignSpectral clusteringActive appearance modelData Interpretation StatisticalComputer Vision and Pattern RecognitionArtificial intelligencebusinessAlgorithmsMedical Image Analysis
researchProduct

Evaluation of intraindividual contrast enhancement variability for determining the maximum achievable consistency in CT

2019

OBJECTIVE. The purpose of this study was to quantify temporal variability in vascular and parenchymal enhancement within the same patient and to determine technique-related factors contributing to this variability. MATERIALS AND METHODS. We identified 100 patients who underwent four CT scans within 12 months with identical acquisition and contrast injection parameters. Enhancement was recorded in the abdominal aorta, main portal vein, liver parenchyma, and subcutaneous fat. Patient demographic and body habitus data were recorded. Injection-related factors were recorded including delay time from contrast injection to image acquisition. All pairwise differences in enhancement within each pati…

MaleContrast enhancementTime Factors030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineConsistency (statistics)MedicineHumansRadiology Nuclear Medicine and imagingAorta AbdominalVariabilityAgedRetrospective StudiesObserver Variationbusiness.industryPortal VeinEnhancementContrast mediaGeneral MedicineMiddle AgedSubcutaneous Fat AbdominalRadiographic Image EnhancementLiver030220 oncology & carcinogenesisFemalebusinessNuclear medicineTomography X-Ray ComputedCT
researchProduct

Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography

2006

OBJECTIVE: The purpose of this study was to investigate whether the amount of intracoronary attenuation influences the diagnostic accuracy of MDCT coronary angiography in the detection of clinically significant stenosis. MATERIALS AND METHODS: One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent MDCT of the heart and conventional coronary angiography were retrospectively selected. The population was divided into two groups depending on median (326 H) coronary vascular enhancement (i.e., low attenuation and high attenuation). The diagnostic accuracy of MDCT for the detection of clinically significant coronary artery lesions (> or = 50% lumen reduct…

MaleCoronary angiographymedicine.medical_specialtycardiac imaging cardiovascular disease contrast media CT coronary arteriographyPopulationLumen (anatomy)Coronary AngiographySensitivity and SpecificityAngina PectorisCoronary artery diseasePredictive Value of TestsmedicineHumansRadiology Nuclear Medicine and imagingSinus rhythmeducationCardiac imagingeducation.field_of_studybusiness.industryAttenuationCoronary StenosisGeneral MedicineMiddle Agedmedicine.diseaseRadiographic Image Enhancementmedicine.anatomical_structureFemaleRadiologyTomography X-Ray ComputedbusinessArteryAmerican Journal of Roentgenology
researchProduct