Comparison of two artificial tear formulations for dry eye through high‐resolution optical coherence tomography

2011

Purpose:  The aim was to determine the efficacy of two artificial eye-drop formulations by analysing the lower tear film meniscus volume through a commercial high-resolution spectral-domain optical coherence tomographer. Methods:  Twenty dry eye patients (12 men, eight women, aged 57.5 ± 8.4 years) with refractive errors from -2.50 to +0.75 D (mean -1.34 ± 1.02 D) and cylinders lower than 1.00 D were examined. Tear meniscus volume was measured before, immediately after and 10, 30 and 60 minutes after instillation using the Copernicus high-resolution spectral-domain optical coherence tomographer (Optopol Tech SA, Zawiercie, Poland). Volume was calculated from the local area obtained from tom…

Malemedicine.medical_specialtyDrug Compoundingmedicine.medical_treatmentDry Eye SyndromesHigh resolutionMeniscus (anatomy)Young AdultOptical coherence tomographyReference ValuesOphthalmologymedicineHumansSurface Tensionmedicine.diagnostic_testbusiness.industryImage Enhancementeye diseasesSurgeryOphthalmologyArtificial tearsmedicine.anatomical_structureVolume (thermodynamics)TearsTearsDry Eye SyndromesFemalesense organsEyelidOphthalmic SolutionsbusinessTomography Optical CoherenceFollow-Up StudiesOptometryClinical and Experimental Optometry
researchProduct

Chromoendoscopy and narrow-band imaging compared with high-resolution magnification endoscopy in Barrett's esophagus.

2008

Background & Aims: The aim of this study was to compare magnified still images obtained with high-resolution white light endoscopy, indigo carmine chromoendoscopy, acetic acid chromoendoscopy, and narrow-band imaging to determine the best technique for use in Barrett's esophagus. Methods: We obtained magnified images from 22 areas with the 4 aforementioned techniques. Seven endoscopists with no specific expertise in Barretes esophagus or advanced imaging techniques and 5 international experts in this field evaluated these 22 areas for overall image quality, mucosal image quality, and vascular image quality. In addition, the regularity of mucosal and vascular patterns and the presence of abn…

Malemedicine.medical_specialtyEsophageal NeoplasmsHigh resolutionIndigo CarmineGastroenterologyChromoendoscopychemistry.chemical_compoundBarrett EsophagusEsophagusInternal medicinemedicineHumansEsophagusColoring AgentsAcetic AcidAgedAged 80 and overObserver VariationNarrow-band imagingMucous MembraneHepatologybusiness.industryGastroenterologyReproducibility of ResultsMiddle Agedmedicine.diseaseImage EnhancementMagnification endoscopymedicine.anatomical_structureIndigo carminechemistryBarrett's esophagusHigh Grade Intraepithelial NeoplasiaFemaleEsophagoscopyNuclear medicinebusinessPrecancerous ConditionsGastroenterology
researchProduct

Fatal venous air embolism: proof and volumetry by helical CT

1995

Malemedicine.medical_specialtyHeart Diseasesbusiness.industryMediastinumGeneral MedicineCranial SinusesIntracranial Embolism and ThrombosisMiddle AgedVenous air embolismHelical ctVeinsRadiographic Image EnhancementSuicideFatal OutcomeEmbolism AirHumansMedicineWounds GunshotRadiology Nuclear Medicine and imagingRadiologyPulmonary EmbolismTomography X-Ray ComputedbusinessNeckEuropean Journal of Radiology
researchProduct

Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary…

2007

Attenuation variability ( measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/infinity) and a 1/50 solution of contrast material ( 400 mgI/ml iomeprol). Scan parameters were: slices/ collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques …

Malemedicine.medical_specialtyMultislice computed tomographyConvolutions KernelsCoronary angiographyIomeprolMyocardial IschemiaContrast MediaCoronary Artery DiseaseIn Vitro TechniquesCoronary AngiographySensitivity and SpecificityIopamidolCoronary artery diseasechemistry.chemical_compoundHounsfield scaleMedicine and Health SciencesmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingAgedConvolutions kernelsCoronary Plaquebusiness.industryAttenuationUltrasoundMultislice computed tomography Coronary angiography Coronary plaque Convolutions kernelsModels CardiovascularGeneral MedicineMiddle Agedmedicine.diseaseImage EnhancementIopamidolCoronary arteriesmedicine.anatomical_structurechemistryRadiology Nuclear Medicine and imagingFemaleRadiologybusinessNuclear medicineTomography Spiral ComputedCardiacCoronary plaqueEx vivoMultislice Computed Tomographymedicine.drug
researchProduct

Digital Tomosynthesis: A New Technique for Imaging Nephrolithiasis. Specific Organ Doses and Effective Doses Compared With Renal Stone Protocol Nonco…

2014

Objective To determine organ-specific doses (ODs) and effective dose (ED) for digital tomosynthesis (DT) and compare it with our institutional renal stone protocol noncontrast computed tomography (NCCT). Methods A validated anthropomorphic male phantom was placed supine on a digital GE Definium 8000 radiological scanner. Thermoluminescent dosimeters were placed in 256 locations and used to measure OD. A routine DT study was performed consisting of 2 scout images and 1 tomographic sweep in a 14.2-degree arc over the phantom. Software is used to recreate a series of coronal images from the sweep. ODs were determined as the sum of the doses for the study. Equivalent doses were calculated by mu…

Malemedicine.medical_specialtyRenal stoneSupine positionDosimetermedicine.diagnostic_testPhantoms Imagingbusiness.industryUrologyComputed tomographyNephrolithiasisRadiation DosageEffective dose (radiation)Imaging phantomTomosynthesisRadiographic Image EnhancementmedicineHumansTomographyRadiologyTomography X-Ray ComputedNuclear medicinebusinessUrology
researchProduct

Improving pediatric radiation dose management using Agfa digital radiography DICOM header information

2007

Dose reduction in pediatric explorations is especially important because of children radiation sensitivity. According to this, with the aim of saving radiation exposure in future clinical practice, we have developed a technique to control delivered dose in pediatric radiographic exams. To that, a computer science program has been developed to calculate entrance skin dose (ESD) provided by AGFA radiology digital system, using the "lgM" parameter exported from Dicom files. ESD values are compared with dose limits established in regulations to detect if children are being exposed to excessive amounts of radiation during their explorations.

Malemedicine.medical_specialtybusiness.industryRadiographyRadiation DosageRadiographic Image EnhancementRadiation exposureDICOMEntrance skin doseChild PreschoolHeaderHumansMedicineDosimetryFemaleDose reductionMedical physicsChildbusinessNuclear medicineSoftwareDigital radiography2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
researchProduct

Polarized multiplex coherent anti-Stokes Raman scattering using a picosecond laser and a fiber supercontinuum

2011

International audience; We perform multiplex coherent anti-Stokes Raman scattering (CARS) micro-spectroscopy with a picosecond pulsed laser and a broadband supercontinuum (SC) generated in photonic crystal fiber. CARS signal stability is achieved using an active fiber coupler that avoids thermal and mechanical drifts. We obtain multiplex CARS spectra for test liquids in the 600–2000 cm−1 spectral range. In addition we investigate the polarization dependence of the CARS spectra when rotating the pump beam linear polarization state relative to the linearly polarized broad stokes SC. From these polarization measurements we deduce the Raman depolarization ratio, the resonant versus nonresonant …

Materials scienceBiomedical EngineeringPhysics::Optics02 engineering and technologySpectrum Analysis Raman01 natural sciencesPattern Recognition Automated010309 opticsBiomaterialssymbols.namesakeLaser linewidthOptics87.64.kp 87.63.ltFiber laser0103 physical sciencesDepolarization ratioFiber Optic TechnologyCoherent anti-Stokes Raman spectroscopy[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]business.industryLasersEquipment Design021001 nanoscience & nanotechnologyImage EnhancementAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsSupercontinuumEquipment Failure AnalysissymbolsOptoelectronicsMicroscopy Polarization0210 nano-technologybusinessRaman spectroscopyRaman scatteringPhotonic-crystal fiber
researchProduct

The effects of linearly increasing flip angles on 3D inflow MR angiography

1994

As recently demonstrated, spin saturation effects in 3D time-of-flight (TOF) MR angiography (MRA) can be reduced by using RF pulses with linearly increasing flip angles (ramp pulses) in the main direction of flow. We developed a model for calculating the signal distribution of proton flow within the excitation volume (slab) for different ramp slopes and compared the results with the measured distribution for the lower-leg arteries. The ramp pulses were generated using the Fourier transformation of the desired excitation profiles. With a bandwidth of 6 kHz and a pulse length of 2.56 ms satisfactory ramps with variable slopes were generated and applied in a standard flow-compensated 3D FISP s…

Materials scienceInflowsymbols.namesakeNuclear magnetic resonanceHumansPopliteal ArteryRadiology Nuclear Medicine and imagingSaturation (magnetic)Fourier AnalysisModels CardiovascularMr angiographyReproducibility of ResultsPulse durationRangingArteriesImage EnhancementMagnetic Resonance ImagingComputational physicsTibial ArteriesFourier transformFibulaRegional Blood FlowBlood CirculationsymbolsSlabBlood VesselsArtifactsAlgorithmsBlood Flow VelocityExcitationMagnetic Resonance in Medicine
researchProduct

Experimentelle In-vitro-Studie zur Evaluierung eines elektronischen Detektors für die digitale Radiographie

2004

Purpose: To evaluate the contrast-detail performance of a flat-panel detector system, we performed a comparative study of this flat-panel system versus storage phosphor and conventional screen-film systems. Materials and Methods: Bone models made of human humeri were prepared with foreign bodies, fracture lines and drilled holes to create artificial fractures, osteolyses or metastases. Immersed in a water bath, hard copy images of these models were acquired with the same exposure dose (55 kV; 3.2 mAs) on the flat-panel detector, two state-of-the-art storage phosphor systems (PCR®, ADC®) and two conventional screen-film systems (Insight®, T-Mat®). Using a standardized protocol with a 4-point…

Materials sciencebusiness.industryRadiographyStorage phosphorDetectorRadiology Nuclear Medicine and imagingRadiographic Image EnhancementNuclear medicinebusinessForeign BodiesImaging phantomFlat panel detectorDigital radiographyRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Advantages of fitting contrast curves using logistic function: a technical note.

2013

Objective The aim of this article is to demonstrate how the contrast properties of an imaging system can be ideally fitted with the use of stripe patterns and the logistic function. Study Design Stripe patterns with defined amounts of line pairs (lp/mm) per mm (10-20 lp/mm) were recorded with the use of digital photostimulable storage phosphor. Scan data and normalized image data were analyzed with the use of ImageJ and MatLab to calculate different contrast curves. Results For original scan data, the goodness of fit was 0.0000019 (sum of squared error [SSE]). The R-square was 0.9998. For normalized data the goodness of fit was 0.0007 (SSE) and the R-square 0.998. An amount of 50% contrast …

Mean squared errorComputer scienceContrast (statistics)Image processingRadiography Dental DigitalPathology and Forensic MedicineRadiographic Image EnhancementLogistic ModelsGoodness of fitStatisticsLine (geometry)Image Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingDentistry (miscellaneous)SurgeryRadiographic Image EnhancementX-Ray Intensifying ScreensOral SurgeryLogistic functionMATLABcomputerAlgorithmAlgorithmscomputer.programming_languageOral surgery, oral medicine, oral pathology and oral radiology
researchProduct