EchoScopy in scanning abdominal diseases: initial clinical experience.

2014

Background and Aims: The introduction of a new type of small handheld ultrasound device brings greater portability and affordability. The basic ultrasound approach with these handheld devices has been defined by European Federation of Societies of Ultrasound in Medicine and Biology (EFSUMB) as “EchoScopy”. The current study aimed to assess the image quality, indications and limitations of a portable pocket “EchoScope” compared with a high-end ultrasound system in abdominal diseases. Methods: 231 consecutive patients were included in this study. Physician A performed ultrasound examinations with a high-end ultrasound system (HEUS), then physician B performed the same ultrasound examination u…

AdultMaleUrologic Diseasesmedicine.medical_specialtyAdolescentImage qualityDigestive System DiseasesPilot ProjectsEndocrine System DiseasesSensitivity and SpecificityLesionYoung AdultVascularityAscitesAbdomenMedicineHumansUltrasonography Doppler ColorProspective cohort studyChildPathologicalHydronephrosisAgedAged 80 and overMiniaturizationbusiness.industryUltrasoundGastroenterologyReproducibility of ResultsEquipment DesignMiddle Agedmedicine.diseaseEquipment Failure AnalysisCardiovascular DiseasesFemaleRadiologymedicine.symptombusinessZeitschrift fur Gastroenterologie
researchProduct

Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques

2008

Purpose To compare three different autocalibrated parallel acquisition techniques (PAT) for quantitative and semiquantitative myocardial perfusion imaging. Materials and Methods Seven healthy volunteers underwent myocardial first-pass perfusion imaging at rest using an SR-TrueFISP pulse sequence without PAT and while using GRAPPA, mSENSE, and TSENSE. signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), normalized upslopes (NUS), and myocardial blood flow (MBF) were calculated. Artifacts, image noise, and overall image quality were qualitatively assessed. Furthermore, the relation between signal intensity (SI) and contrast medium (CM) concentration was determined in phantoms. Results …

AdultMalemedicine.diagnostic_testPhantoms Imagingbusiness.industryImage qualityPerfusion scanningPulse sequenceBlood flowMagnetic Resonance ImagingMyocardial perfusion imagingContrast mediumCoronary CirculationHealthy volunteerscardiovascular systemmedicineImage noiseHumansFemaleRadiology Nuclear Medicine and imagingNuclear medicinebusinessMathematicsJournal of Magnetic Resonance Imaging
researchProduct

Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography

1996

The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D- echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D- echocardiographic data acquisition was performed by automatic transducer rotation at 2 degree increments over a span of 180 degrees. The transesophageal probe was linked to an ultrasound unit and to a 3D- workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes…

AdultMalemedicine.medical_specialtyDuplex ultrasonographyImage qualitymedicine.medical_treatmentDoppler echocardiographyMitral valve stenosisMitral valveImage Processing Computer-AssistedmedicineHumansMitral Valve StenosisRadiology Nuclear Medicine and imagingCardiac imagingAgedCardiac catheterizationObserver Variationmedicine.diagnostic_testbusiness.industryUltrasoundMiddle Agedmedicine.diseaseEchocardiography Dopplermedicine.anatomical_structureFemaleRadiologyCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealThe International Journal of Cardiac Imaging
researchProduct

MR angiography of the pedal arteries with gadobenate dimeglumine, a contrast agent with increased relaxivity, and comparison with selective intraarte…

2007

Purpose To compare gadobenate dimeglumine (Gd-BOPTA)–enhanced MR angiography (i.e., contrast-enhanced MRA [CE-MRA]) of the pedal vasculature with selective digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). Materials and Methods A total of 22 patients with PAOD were prospectively examined at 1.5T. For contrast enhancement, 0.1 mmol/kg body weight of Gd-BOPTA were applied. MRA consisted of dynamic imaging with acquisition of six consecutive data sets. Acquisition time for each data set was 24 seconds, voxel size was 1.0 × 1.0 × 1.3 mm3. A total of 20 out of 22 patient underwent selective DSA, two patients fine-needle DSA. DSA and MRA were per…

AdultMalemedicine.medical_specialtyImage qualitymedia_common.quotation_subjectDynamic imagingContrast MediaArterial Occlusive DiseasesMegluminemedicineOrganometallic CompoundsContrast (vision)HumansRadiology Nuclear Medicine and imagingIn patientcardiovascular diseasesProspective StudiesGADOBENATE DIMEGLUMINEVascular Patencymedia_commonAgedAged 80 and overPeripheral Vascular Diseasesmedicine.diagnostic_testbusiness.industryFootMr angiographyAngiography Digital SubtractionDigital subtraction angiographyMiddle Agedmedicine.diseasebody regionsStenosiscardiovascular systemFemaleRadiologyNuclear medicinebusinessMagnetic Resonance Angiographycirculatory and respiratory physiologyJournal of magnetic resonance imaging : JMRI
researchProduct

Rapid Musculoskeletal Magnetic Resonance Imaging Using Integrated Parallel Acquisition Techniques (IPAT) - Initial Experiences

2003

Purpose To investigate the feasibility of using multiple receiver coil elements for time saving integrated parallel imaging techniques (iPAT) in traumatic musculoskeletal disorders. Material and methods 6 patients with traumatic derangements of the knee, ankle and hip underwent MR imaging at 1.5 T. For signal detection of the knee and ankle, we used a 6-channel body array coil that was placed around the joints, for hip imaging two 4-channel body array coils and two elements of the spine array coil were combined for signal detection. All patients were investigated with a standard imaging protocol that mainly consisted of different turbo spin-echo sequences (PD-, T (2)-weighted TSE with and w…

AdultMalemedicine.medical_specialtyTime FactorsAdolescentImage qualityKnee InjuriesSensitivity and SpecificityFractures BoneMusculoskeletal disordermedicineHumansRadiology Nuclear Medicine and imagingDetection theoryAnkle InjuriesChildAgedSensitivity encodingAged 80 and overMusculoskeletal imagingmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance ImagingFemoral Neck FracturesSurgerymedicine.anatomical_structureElectromagnetic coilFeasibility StudiesFemaleAnklebusinessAlgorithmsHip InjuriesBiomedical engineeringRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Simulating Images Seen by Patients with Inhomogeneous Sensitivity Losses

2012

PURPOSE We aim to simulate how colored images are perceived by subjects with local achromatic and chromatic contrast sensitivity losses in the visual field (VF). METHODS The spatiochromatic corresponding pair algorithm, introduced in a previous article (J Opt Soc Am (A) 2004;21:176-186), has been implemented with a linear model of the visual system. Spatial information is processed separately by the chromatic and achromatic mechanisms by means of a multiscale model, with sensors selective to frequency, orientation, and spatial position, whose mechanism-dependent relative weights change with the spatial location of the image. These weights have been obtained from perimetric data from a patie…

Adultgenetic structuresComputer scienceImage qualityColor visionOptic Atrophy Hereditary Leberlaw.inventionContrast SensitivitylawmedicineHumansChromatic scaleSpatial analysisbusiness.industryReproducibility of ResultsPattern recognitionmedicine.diseaseVisual fieldOphthalmologyAchromatic lensVisual Field TestsSpatial frequencyArtificial intelligenceVisual FieldsbusinessDichromacyColor PerceptionOptometryOptometry and Vision Science
researchProduct

Lensless object scanning holography for two-dimensional mirror-like and diffuse reflective objects

2013

Recently proposed lensless object scanning holography (LOSH) [Opt. Express 20, 9382 (2012)] is a fully lensless method capable of improving the image quality in digital Fourier holography applied to one-dimensional (1D) reflective objects and it involves a very simplified experimental setup. LOSH is based on the recording and digital postprocessing of a set of digital lensless Fourier transform holograms, which finally results in a synthetic image with improved resolution, field-of-view (FOV), signal-to-noise ratio (SNR), and depth of field. In this paper, LOSH is extended to the cases of two-dimensional (2D) mirror-like and 1D diffuse-based objects. For 2D mirror-like objects, the experime…

ApertureImage qualityComputer sciencebusiness.industryHolographyImage processingSuperresolutionAtomic and Molecular Physics and Opticslaw.inventionSpeckle patternOpticslawDigital image processingDepth of fieldElectrical and Electronic EngineeringbusinessEngineering (miscellaneous)Image resolutionDigital holographyFresnel diffractionApplied Optics
researchProduct

Image quality with multifocal intraocular lenses and the effect of pupil size

2007

Purpose To analyze the image quality with a refractive and 2 hybrid refractive–diffractive multifocal intraocular lenses (IOLs) in vitro to determine the IOL modulation transfer function (MTF) following the EN-ISO international standard for distance and near vision and to study the IOLs' behavior with different pupil sizes. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods This study evaluated 4 IOLs: the hybrid refractive–diffractive AcrySof ReSTOR SN60D3 (Alcon) and Tecnis ZM900 (AMO), the refractive ReZoom NXG (AMO), and the monofocal AcrySof SN60WF (Alcon). The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Sci…

Artificial corneaOptics and PhotonicsImage qualitymedicine.medical_treatmentIntraocular lensProsthesis DesignModels BiologicalPupilContrast SensitivityOpticsOptical transfer functionmedicineHumansImaging scienceMathematicsLenses IntraocularFourier Analysisbusiness.industryPupil sizePupilMultifocal intraocular lensSensory SystemsOphthalmologyOptometrySurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Free-depths reconstruction with synthetic impulse response in integral imaging

2015

Integral Imaging provides spatial and angular information of three-dimensional (3D) objects, which can be used both for 3D display and for computational post-processing purposes. In order to recover the depth information from an integral image, several algorithms have been developed. In this paper, we propose a new free depth synthesis and reconstruction method based on the two-dimensional (2D) deconvolution between the integral image and a simplified version of the periodic impulse response function (IRF) of the system. The period of the IRF depends directly on the axial position within the object space. Then, we can retrieve the depth information by performing the deconvolution with compu…

Blind deconvolutionIntegral imagingComputer scienceImage qualitybusiness.industryFast Fourier transformImage processingImpulse (physics)Atomic and Molecular Physics and OpticsOpticsDigital image processingDeconvolutionbusinessImpulse responseOptics Express
researchProduct

Angiocardiographic digital still images compressed via irreversible methods: concepts and experiments.

1997

Abstract We defined, implemented and tested two new methods for irreversible compression of angiocardiographic still images: brightness error limitation (BEL) and pseudo-gradient adaptive brightness and contrast error limitation (PABCEL). The scan path used to compress the digital images is based on the Peano–Hilbert plane-filling curve. The compression methods limit, for each pixel, the brightness errors introduced when approximating the original image (i.e. the difference between the values of corresponding pixels as grey levels). Additional limitations are imposed to the contrast error observed when considering along the scan path consecutive pixels of both the original and the reconstru…

BrightnessPixelImage qualityComputer sciencebusiness.industrymedia_common.quotation_subjectAngiocardiographyHealth InformaticsCoronary Diseasecomputer.file_formatJPEGVisualizationDigital imageSoftware DesignCompression ratioContrast (vision)HumansComputer visionArtificial intelligencebusinesscomputerAlgorithmsmedia_commonInternational journal of medical informatics
researchProduct